0e0772596e
Signed-off-by: pettershao-ragilenetworks pettershao@ragilenetworks.com What I did it Add new platform x86_64-ragile_ra-b6510-32c-r0 (Trident 3) ASIC Vendor: Broadcom Switch ASIC: Trident 3 Port Config: 32x100G Add new platform x86_64-ragile_ra-b6920-4s-r0 (Tomahawk 3) ASIC Vendor: Broadcom Switch ASIC: Tomahawk 3 Port Config: 128x100G -How I did it Provide device and platform related files. -How to verify it show platform fan show platform ssdhealth show platform psustatus show platform summary show platform syseeprom show platform temperature show interface status
346 lines
10 KiB
Python
Executable File
346 lines
10 KiB
Python
Executable File
#!/usr/bin/env python3
|
||
# -*- coding: UTF-8 -*-
|
||
|
||
import click
|
||
import os
|
||
import time
|
||
from ragileconfig import GLOBALCONFIG, GLOBALINITPARAM, GLOBALINITCOMMAND, MAC_LED_RESET, STARTMODULE, i2ccheck_params
|
||
from ragileutil import rgpciwr, os_system, rgi2cset, io_wr
|
||
|
||
CONTEXT_SETTINGS = dict(help_option_names=['-h', '--help'])
|
||
|
||
class AliasedGroup(click.Group):
|
||
def get_command(self, ctx, cmd_name):
|
||
rv = click.Group.get_command(self, ctx, cmd_name)
|
||
if rv is not None:
|
||
return rv
|
||
matches = [x for x in self.list_commands(ctx)
|
||
if x.startswith(cmd_name)]
|
||
if not matches:
|
||
return None
|
||
elif len(matches) == 1:
|
||
return click.Group.get_command(self, ctx, matches[0])
|
||
ctx.fail('Too many matches: %s' % ', '.join(sorted(matches)))
|
||
|
||
def log_os_system(cmd):
|
||
u'''execute shell command'''
|
||
status, output = os_system(cmd)
|
||
if status:
|
||
print(output)
|
||
return status, output
|
||
|
||
def write_sysfs_value(reg_name, value):
|
||
u'''write sysfs file'''
|
||
mb_reg_file = "/sys/bus/i2c/devices/" + reg_name
|
||
if (not os.path.isfile(mb_reg_file)):
|
||
print(mb_reg_file, 'not found !')
|
||
return False
|
||
try:
|
||
with open(mb_reg_file, 'w') as fd:
|
||
fd.write(value)
|
||
except Exception as error:
|
||
return False
|
||
return True
|
||
|
||
def check_driver():
|
||
u'''whether there is driver start with rg'''
|
||
status, output = log_os_system("lsmod | grep rg | wc -l")
|
||
#System execution error
|
||
if status:
|
||
return False
|
||
if output.isdigit() and int(output) > 0:
|
||
return True
|
||
else:
|
||
return False
|
||
|
||
def get_pid(name):
|
||
ret = []
|
||
for dirname in os.listdir('/proc'):
|
||
if dirname == 'curproc':
|
||
continue
|
||
try:
|
||
with open('/proc/{}/cmdline'.format(dirname), mode='r') as fd:
|
||
content = fd.read()
|
||
except Exception:
|
||
continue
|
||
if name in content:
|
||
ret.append(dirname)
|
||
return ret
|
||
|
||
def start_avs_ctrl():
|
||
cmd = "nohup avscontrol.py start >/dev/null 2>&1 &"
|
||
rets = get_pid("avscontrol.py")
|
||
if len(rets) == 0:
|
||
os.system(cmd)
|
||
|
||
def start_fan_ctrl():
|
||
if STARTMODULE['fancontrol'] == 1:
|
||
cmd = "nohup fancontrol.py start >/dev/null 2>&1 &"
|
||
rets = get_pid("fancontrol.py")
|
||
if len(rets) == 0:
|
||
os.system(cmd)
|
||
|
||
def starthal_fanctrl():
|
||
if STARTMODULE.get('hal_fanctrl',0) == 1:
|
||
cmd = "nohup hal_fanctrl.py start >/dev/null 2>&1 &"
|
||
rets = get_pid("hal_fanctrl.py")
|
||
if len(rets) == 0:
|
||
os.system(cmd)
|
||
|
||
def starthal_ledctrl():
|
||
if STARTMODULE.get('hal_ledctrl',0) == 1:
|
||
cmd = "nohup hal_ledctrl.py start >/dev/null 2>&1 &"
|
||
rets = get_pid("hal_ledctrl.py")
|
||
if len(rets) == 0:
|
||
os.system(cmd)
|
||
|
||
def start_dev_monitor():
|
||
if STARTMODULE.get('dev_monitor',0) == 1:
|
||
cmd = "nohup dev_monitor.py start >/dev/null 2>&1 &"
|
||
rets = get_pid("dev_monitor.py")
|
||
if len(rets) == 0:
|
||
os.system(cmd)
|
||
|
||
def start_slot_monitor():
|
||
if STARTMODULE.get('slot_monitor',0) == 1:
|
||
cmd = "nohup slot_monitor.py start >/dev/null 2>&1 &"
|
||
rets = get_pid("slot_monitor.py")
|
||
if len(rets) == 0:
|
||
os.system(cmd)
|
||
|
||
def stop_fan_ctrl():
|
||
u'''disable fan timer service'''
|
||
if STARTMODULE['fancontrol'] == 1:
|
||
rets = get_pid("fancontrol.py") #
|
||
for ret in rets:
|
||
cmd = "kill "+ ret
|
||
os.system(cmd)
|
||
return True
|
||
|
||
def stophal_ledctrl():
|
||
if STARTMODULE.get('hal_ledctrl',0) == 1:
|
||
rets = get_pid("hal_ledctrl.py")
|
||
for ret in rets:
|
||
cmd = "kill "+ ret
|
||
os.system(cmd)
|
||
return True
|
||
|
||
|
||
def stop_dev_monitor():
|
||
u'''disable the fan timer service'''
|
||
if STARTMODULE.get('dev_monitor',0) == 1:
|
||
rets = get_pid("dev_monitor.py") #
|
||
for ret in rets:
|
||
cmd = "kill "+ ret
|
||
os.system(cmd)
|
||
return True
|
||
|
||
def stop_slot_monitor():
|
||
u'''disable slot timer service'''
|
||
if STARTMODULE.get('slot_monitor',0) == 1:
|
||
rets = get_pid("slot_monitor.py") #
|
||
for ret in rets:
|
||
cmd = "kill "+ ret
|
||
os.system(cmd)
|
||
return True
|
||
|
||
def rm_dev(bus, loc):
|
||
cmd = "echo 0x%02x > /sys/bus/i2c/devices/i2c-%d/delete_device" % (loc, bus)
|
||
devpath = "/sys/bus/i2c/devices/%d-%04x"%(bus, loc)
|
||
if os.path.exists(devpath):
|
||
log_os_system(cmd)
|
||
|
||
def add_dev(name, bus, loc):
|
||
if name == "lm75":
|
||
time.sleep(0.1)
|
||
pdevpath = "/sys/bus/i2c/devices/i2c-%d/" % (bus)
|
||
for i in range(1, 100):#wait for mother-bus generation,maximum wait time is 10s
|
||
if os.path.exists(pdevpath) == True:
|
||
break
|
||
time.sleep(0.1)
|
||
if i % 10 == 0:
|
||
click.echo("%%DEVICE_I2C-INIT: %s not found, wait 0.1 second ! i %d " % (pdevpath,i))
|
||
|
||
cmd = "echo %s 0x%02x > /sys/bus/i2c/devices/i2c-%d/new_device" % (name, loc, bus)
|
||
devpath = "/sys/bus/i2c/devices/%d-%04x"%(bus, loc)
|
||
if os.path.exists(devpath) == False:
|
||
os.system(cmd)
|
||
|
||
def removedevs():
|
||
devs = GLOBALCONFIG["DEVS"]
|
||
for index in range(len(devs)-1, -1, -1 ):
|
||
rm_dev(devs[index]["bus"] , devs[index]["loc"])
|
||
|
||
def adddevs():
|
||
devs = GLOBALCONFIG["DEVS"]
|
||
for dev in range(0, devs.__len__()):
|
||
add_dev(devs[dev]["name"], devs[dev]["bus"] , devs[dev]["loc"])
|
||
|
||
def checksignaldriver(name):
|
||
modisexistcmd = "lsmod | grep %s | wc -l" % name
|
||
status, output = log_os_system(modisexistcmd)
|
||
#System execution error
|
||
if status:
|
||
return False
|
||
if output.isdigit() and int(output) > 0:
|
||
return True
|
||
else:
|
||
return False
|
||
|
||
def adddriver(name, delay):
|
||
cmd = "modprobe %s" % name
|
||
if delay != 0:
|
||
time.sleep(delay)
|
||
if checksignaldriver(name) != True:
|
||
log_os_system(cmd)
|
||
|
||
def removedriver(name, delay):
|
||
realname = name.lstrip().split(" ")[0];
|
||
cmd = "rmmod -f %s" % realname
|
||
if checksignaldriver(realname):
|
||
log_os_system(cmd)
|
||
|
||
def removedrivers():
|
||
u'''remove all drivers'''
|
||
if GLOBALCONFIG is None:
|
||
click.echo("%%DEVICE_I2C-INIT: load global config failed.")
|
||
return
|
||
drivers = GLOBALCONFIG.get("DRIVERLISTS", None)
|
||
if drivers is None:
|
||
click.echo("%%DEVICE_I2C-INIT: load driver list failed.")
|
||
return
|
||
for index in range(len(drivers)-1, -1, -1 ):
|
||
delay = 0
|
||
name = ""
|
||
if type(drivers[index]) == dict and "delay" in drivers[index]:
|
||
name = drivers[index].get("name")
|
||
delay = drivers[index]["delay"]
|
||
else:
|
||
name = drivers[index]
|
||
removedriver(name, delay)
|
||
|
||
def adddrivers():
|
||
u'''add drivers'''
|
||
if GLOBALCONFIG is None:
|
||
click.echo("%%DEVICE_I2C-INIT: load global config failed.")
|
||
return
|
||
drivers = GLOBALCONFIG.get("DRIVERLISTS", None)
|
||
if drivers is None:
|
||
click.echo("%%DEVICE_I2C-INIT: load driver list failed.")
|
||
return
|
||
for index in range(0 ,len(drivers)):
|
||
delay = 0
|
||
name = ""
|
||
if type(drivers[index]) == dict and "delay" in drivers[index]:
|
||
name = drivers[index].get("name")
|
||
delay = drivers[index]["delay"]
|
||
else:
|
||
name = drivers[index]
|
||
adddriver(name, delay)
|
||
|
||
def otherinit():
|
||
for index in GLOBALINITPARAM:
|
||
index_type = index.get("type", None)
|
||
if index_type == "io":
|
||
ret = io_wr(index.get("offset"), index.get("val"))
|
||
else:
|
||
ret, _ = rgi2cset(
|
||
index.get("bus"),
|
||
index.get("devaddr"),
|
||
index.get("offset"),
|
||
index.get("val")
|
||
)
|
||
if not ret:
|
||
click.echo("%%DEVICE_I2C-INIT: init param %s failed." % index.get("name"))
|
||
|
||
for index in GLOBALINITCOMMAND:
|
||
log_os_system(index)
|
||
|
||
def unload_driver():
|
||
u'''remove devices and drivers'''
|
||
stop_dev_monitor() # disable removable device driver monitors
|
||
stop_fan_ctrl() # disable fan-control service
|
||
removedevs() # remove other devices
|
||
removedrivers() # remove drivers
|
||
|
||
def reload_driver():
|
||
u'''reload devices and drivers'''
|
||
removedevs() # remove other devices
|
||
removedrivers() # remove drivers
|
||
time.sleep(1)
|
||
adddrivers()
|
||
adddevs()
|
||
|
||
|
||
def i2c_check(bus,retrytime = 6):
|
||
try:
|
||
i2cpath = "/sys/bus/i2c/devices/" + bus
|
||
while retrytime and not os.path.exists(i2cpath):
|
||
click.echo("%%DEVICE_I2C-HA: i2c bus abnormal, last bus %s is not exist." % i2cpath)
|
||
reload_driver()
|
||
retrytime -= 1
|
||
time.sleep(1)
|
||
except Exception as e:
|
||
click.echo("%%DEVICE_I2C-HA: %s" % str(e))
|
||
return
|
||
|
||
def set_mac_leds(data):
|
||
'''write pci register'''
|
||
pcibus = MAC_LED_RESET.get("pcibus")
|
||
slot = MAC_LED_RESET.get("slot")
|
||
fn = MAC_LED_RESET.get("fn")
|
||
bar = MAC_LED_RESET.get("bar")
|
||
offset = MAC_LED_RESET.get("offset")
|
||
val = MAC_LED_RESET.get(data, None)
|
||
if val is None:
|
||
click.echo("%%DEVICE_I2C-INIT: set_mac_leds wrong input")
|
||
return
|
||
rgpciwr(pcibus, slot, fn, bar, offset, val)
|
||
|
||
def load_driver():
|
||
u'''load devices and drivers'''
|
||
adddrivers()
|
||
adddevs()
|
||
if STARTMODULE.get("i2ccheck",0) == 1: #i2c HA
|
||
busend = i2ccheck_params.get("busend")
|
||
retrytime = i2ccheck_params.get("retrytime")
|
||
i2c_check(busend,retrytime)
|
||
start_fan_ctrl() # enable fan
|
||
starthal_fanctrl() # enable fan control
|
||
starthal_ledctrl() # enable LED control
|
||
if STARTMODULE['avscontrol'] == 1:
|
||
start_avs_ctrl() # avs voltage-adjustment
|
||
start_dev_monitor() # enable removable device driver monitors
|
||
start_slot_monitor() # slot insertion and removal initialization monitor
|
||
otherinit(); # other initialization, QSFP initialization
|
||
if STARTMODULE.get("macledreset", 0) == 1:
|
||
set_mac_leds("reset")
|
||
|
||
@click.group(cls=AliasedGroup, context_settings=CONTEXT_SETTINGS)
|
||
def main():
|
||
'''device operator'''
|
||
pass
|
||
|
||
|
||
@main.command()
|
||
def start():
|
||
'''load device '''
|
||
if check_driver():
|
||
unload_driver()
|
||
load_driver()
|
||
|
||
@main.command()
|
||
def stop():
|
||
'''stop device '''
|
||
unload_driver()
|
||
|
||
@main.command()
|
||
def restart():
|
||
'''restart device'''
|
||
unload_driver()
|
||
load_driver()
|
||
|
||
if __name__ == '__main__':
|
||
u'''device_i2c operation'''
|
||