d8ee1e6a63
#### Why I did it The capability files were incorrect in comparison to the marketing spec of the SN4410 platform. #### How I did it Aligned the capability files according to the marketing spec. #### How to verify it Did basic manual sanity checks: - Check if critical docker containers were UP - Check if interfaces were created and were UP - Check if interfaces created in the syncd docker container by executing – sx_api_ports_dump.py script - Check the logs from the start of the switch – everything was OK - Verified the port breakout |
||
---|---|---|
.. | ||
ACS-MSN4410 | ||
plugins | ||
default_sku | ||
pcie.yaml | ||
platform_components.json | ||
platform_reboot | ||
platform_wait | ||
platform.json | ||
pmon_daemon_control.json | ||
sensors.conf | ||
system_health_monitoring_config.json | ||
thermal_policy.json |