2528b70630
- Why I did it Mellanox MSN2410 platforms have a non-functional error log: "ERR pmon#sensord: Error getting sensor data: dps460/#10: Can't read". This error is because of a firmware issue with some PSU, we are not able to upgrade the FW online. Since there is no functional impact, this error log can be ignored safely - How I did it Add a new rsyslog rule to the rsyslog-container.conf.j2, if the docker name is pmon and the platform name matches, the new rule will be inserted into the docker rsyslogd.conf - How to verify it run regression on the MSN2410 platform to make the error log will not be printed to the syslog. Signed-off-by: Kebo Liu <kebol@nvidia.com> |
||
---|---|---|
.. | ||
rsyslog.d | ||
rsyslog-config.service | ||
rsyslog-config.sh | ||
rsyslog-container.conf.j2 | ||
rsyslog.conf.j2 |