Why I did it The sensors and sensord processes were reporting data on unused sensors. This lead to ALARM messages or erroneous values that could be misinterpreted. How I did it Ignore the affected sensors in the sensors.conf How to verify it Check that there are no longer ALARM messages from sensord in the syslog or in the output of sensors
61 lines
1.4 KiB
Plaintext
61 lines
1.4 KiB
Plaintext
# libsensors configuration file for DCS-7060CX-32S
|
|
# ------------------------------------------------
|
|
#
|
|
|
|
bus "i2c-2" "SCD 0000:02:00.0 SMBus master 0 bus 0"
|
|
bus "i2c-3" "SCD 0000:02:00.0 SMBus master 0 bus 1"
|
|
bus "i2c-5" "SCD 0000:02:00.0 SMBus master 0 bus 3"
|
|
bus "i2c-6" "SCD 0000:02:00.0 SMBus master 0 bus 4"
|
|
bus "i2c-7" "SCD 0000:02:00.0 SMBus master 0 bus 5"
|
|
|
|
chip "k10temp-pci-00c3"
|
|
label temp1 "Cpu temp sensor"
|
|
|
|
chip "fam15h_power-pci-00c4"
|
|
ignore power1
|
|
|
|
chip "max6697-i2c-2-1a"
|
|
label temp1 "Board sensor"
|
|
set temp1_max 95
|
|
|
|
label temp2 "Switch chip left sensor"
|
|
set temp2_max 95
|
|
set temp2_crit 105
|
|
|
|
ignore temp3
|
|
ignore temp4
|
|
ignore temp5
|
|
|
|
label temp6 "Switch chip right sensor"
|
|
set temp6_max 95
|
|
set temp6_crit 105
|
|
|
|
label temp7 "Front panel temp sensor"
|
|
set temp7_max 65
|
|
set temp7_crit 75
|
|
|
|
chip "max6658-i2c-3-4c"
|
|
label temp1 "Cpu board temp sensor"
|
|
set temp1_max 75
|
|
set temp1_crit 80
|
|
|
|
label temp2 "Back panel temp sensor"
|
|
set temp2_max 75
|
|
set temp2_crit 80
|
|
|
|
chip "pmbus-i2c-6-58"
|
|
label temp1 "Power supply 1 hotspot sensor"
|
|
label temp2 "Power supply 1 inlet temp sensor"
|
|
label temp3 "Power supply 1 exhaust temp sensor"
|
|
|
|
ignore fan2
|
|
ignore fan3
|
|
|
|
chip "pmbus-i2c-5-58"
|
|
label temp1 "Power supply 2 hotspot sensor"
|
|
label temp2 "Power supply 2 inlet temp sensor"
|
|
label temp3 "Power supply 2 exhaust temp sensor"
|
|
|
|
ignore fan2
|
|