sonic-buildimage/device/mellanox/x86_64-mlnx_msn2410-r0/sensors.conf
Kebo Liu 20ba1e2406 [Mellanox] Remove SFP sensors from sensors.conf (#17631)
- Why I did it
The cable thermal sensors will be deprecated from the kernel driver. When cable host management is enabled, NOS will fetch the cable temperature from cable EEPROM, kernel driver will not provide the sysfs anymore.

- How I did it
Remove the relevant sensor form the conf files

- How to verify it
Run sonic mgmt sensor test

Signed-off-by: Kebo Liu <kebol@nvidia.com>
2024-02-19 16:33:23 +08:00

138 lines
4.0 KiB
Plaintext

################################################################################
# Copyright (c) 2020 Mellanox Technologies
#
# Platform specific sensors config for SN2410
################################################################################
# Temperature sensors
bus "i2c-2" "i2c-1-mux (chan_id 1)"
chip "mlxsw-i2c-*-48"
label temp1 "Ambient ASIC Temp"
bus "i2c-7" "i2c-1-mux (chan_id 7)"
chip "lm75-i2c-7-4a"
label temp1 "Ambient Port Temp"
bus "i2c-17" "i2c-1-mux (chan_id 17)"
chip "lm75-i2c-17-49"
label temp1 "Ambient Fan Temp"
chip "acpitz-virtual-0"
label temp1 "ACPI CPU Temp"
label temp2 "ACPI Board Temp"
# Power controllers
bus "i2c-5" "i2c-1-mux (chan_id 5)"
chip "pmbus-i2c-*-41"
label in1 "PMB-1 PSU 12V Rail (in)"
label in2 "PMB-1 0.9V VCORE Rail (out)"
label temp1 "PMB-1 Temp 1"
label temp2 "PMB-1 Temp 2"
ignore power1
label power2 "PMB-1 0.9V VCORE Rail Pwr (out)"
ignore curr1
label curr2 "PMB-1 0.9V VCORE Rail Curr (out)"
chip "pmbus-i2c-*-27"
label in1 "PMB-2 PSU 12V Rail (in)"
label in2 "PMB-2 3.3V Rail (out)"
label in3 "PMB-2 1.2V Rail (out)"
label temp1 "PMB-2 Temp 1"
label temp2 "PMB-2 Temp 2"
ignore power1
label power2 "PMB-2 3.3V Rail Pwr (out)"
label power3 "PMB-2 1.2V Rail Pwr (out)"
ignore curr1
label curr2 "PMB-2 3.3V Rail Curr (out)"
label curr3 "PMB-2 1.2V Rail Curr (out)"
# Power supplies
bus "i2c-10" "i2c-1-mux (chan_id 10)"
chip "dps460-i2c-*-58"
label in1 "PSU-2(R) 220V Rail (in)"
label in2 "PSU-2(R) 12V Rail (out)"
label fan1 "PSU-2(R) Fan 1"
label temp1 "PSU-2(R) Temp 1"
label temp2 "PSU-2(R) Temp 2"
label power1 "PSU-2(R) 220V Rail Pwr (in)"
label power2 "PSU-2(R) 12V Rail Pwr (out)"
label curr1 "PSU-2(R) 220V Rail Curr (in)"
label curr2 "PSU-2(R) 12V Rail Curr (out)"
chip "dps460-i2c-*-59"
label in1 "PSU-1(L) 220V Rail (in)"
label in2 "PSU-1(L) 12V Rail (out)"
label fan1 "PSU-1(L) Fan 1"
label temp1 "PSU-1(L) Temp 1"
label temp2 "PSU-1(L) Temp 2"
label power1 "PSU-1(L) 220V Rail Pwr (in)"
label power2 "PSU-1(L) 12V Rail Pwr (out)"
label curr1 "PSU-1(L) 220V Rail Curr (in)"
label curr2 "PSU-1(L) 12V Rail Curr (out)"
# Chassis fans
bus "i2c-2" "i2c-1-mux (chan_id 1)"
chip "mlxsw-i2c-*-48"
label fan1 "Chassis Drawer-1 Fan-1"
label fan2 "Chassis Drawer-1 Fan-2"
label fan3 "Chassis Drawer-2 Fan-1"
label fan4 "Chassis Drawer-2 Fan-2"
label fan5 "Chassis Drawer-3 Fan-1"
label fan6 "Chassis Drawer-3 Fan-2"
label fan7 "Chassis Drawer-4 Fan-1"
label fan8 "Chassis Drawer-4 Fan-2"
ignore temp2
ignore temp3
ignore temp4
ignore temp5
ignore temp6
ignore temp7
ignore temp8
ignore temp9
ignore temp10
ignore temp11
ignore temp12
ignore temp13
ignore temp14
ignore temp15
ignore temp16
ignore temp17
ignore temp18
ignore temp19
ignore temp20
ignore temp21
ignore temp22
ignore temp23
ignore temp24
ignore temp25
ignore temp26
ignore temp27
ignore temp28
ignore temp29
ignore temp30
ignore temp31
ignore temp32
ignore temp33
ignore temp34
ignore temp35
ignore temp36
ignore temp37
ignore temp38
ignore temp39
ignore temp40
ignore temp41
ignore temp42
ignore temp43
ignore temp44
ignore temp45
ignore temp46
ignore temp47
ignore temp48
ignore temp49
ignore temp50
ignore temp51
ignore temp52
ignore temp53
ignore temp54
ignore temp55
ignore temp56
ignore temp57