Copying platform.json file into an empty /usr/share/sonic/platform directory does not mimic an actual device. A more correct approach is to create a /usr/share/sonic/platform symlink which links to the actual platform directory; this is more like what is done inside SONiC containers. Then, we only need to copy the platform.json file into the actual platform directory; the symlink takes care of the alternative path, and also exposes all the other files in the platform directory.
139 lines
4.5 KiB
Bash
Executable File
139 lines
4.5 KiB
Bash
Executable File
#!/bin/bash -e
|
|
|
|
# Generate configuration
|
|
|
|
# NOTE: 'PLATFORM' and 'HWSKU' environment variables are set
|
|
# in the Dockerfile so that they persist for the life of the container
|
|
|
|
ln -sf /usr/share/sonic/device/$PLATFORM /usr/share/sonic/platform
|
|
ln -sf /usr/share/sonic/device/$PLATFORM/$HWSKU /usr/share/sonic/hwsku
|
|
|
|
pushd /usr/share/sonic/hwsku
|
|
|
|
# filter available front panel ports in lanemap.ini
|
|
[ -f lanemap.ini.orig ] || cp lanemap.ini lanemap.ini.orig
|
|
for p in $(ip link show | grep -oE "eth[0-9]+" | grep -v eth0); do
|
|
grep ^$p: lanemap.ini.orig
|
|
done > lanemap.ini
|
|
|
|
# filter available sonic front panel ports in port_config.ini
|
|
[ -f port_config.ini.orig ] || cp port_config.ini port_config.ini.orig
|
|
grep ^# port_config.ini.orig > port_config.ini
|
|
for lanes in $(awk -F ':' '{print $2}' lanemap.ini); do
|
|
grep -E "\s$lanes\s" port_config.ini.orig
|
|
done >> port_config.ini
|
|
|
|
popd
|
|
|
|
[ -d /etc/sonic ] || mkdir -p /etc/sonic
|
|
|
|
if [[ -f /usr/share/sonic/virtual_chassis/default_config.json ]]; then
|
|
CHASS_CFG="-j /usr/share/sonic/virtual_chassis/default_config.json"
|
|
fi
|
|
|
|
SYSTEM_MAC_ADDRESS=$(ip link show eth0 | grep ether | awk '{print $2}')
|
|
if [ -f /etc/sonic/init_cfg.json ]; then
|
|
sonic-cfggen -j /etc/sonic/init_cfg.json -a '{"DEVICE_METADATA":{"localhost": {"mac": "'$SYSTEM_MAC_ADDRESS'"}}}' $CHASS_CFG --print-data > /tmp/init_cfg.json
|
|
mv /tmp/init_cfg.json /etc/sonic/init_cfg.json
|
|
else
|
|
sonic-cfggen -a '{"DEVICE_METADATA":{"localhost": {"mac": "'$SYSTEM_MAC_ADDRESS'"}}}' $CHASS_CFG --print-data > /etc/sonic/init_cfg.json
|
|
fi
|
|
|
|
if [ -f /etc/sonic/config_db.json ]; then
|
|
sonic-cfggen -j /etc/sonic/init_cfg.json -j /etc/sonic/config_db.json --print-data > /tmp/config_db.json
|
|
mv /tmp/config_db.json /etc/sonic/config_db.json
|
|
else
|
|
# generate and merge buffers configuration into config file
|
|
sonic-cfggen -k $HWSKU -p /usr/share/sonic/device/$PLATFORM/platform.json -t /usr/share/sonic/hwsku/buffers.json.j2 > /tmp/buffers.json
|
|
sonic-cfggen -j /etc/sonic/init_cfg.json -t /usr/share/sonic/hwsku/qos.json.j2 > /tmp/qos.json
|
|
sonic-cfggen -p /usr/share/sonic/device/$PLATFORM/platform.json -k $HWSKU --print-data > /tmp/ports.json
|
|
# change admin_status from up to down; Test cases dependent
|
|
sed -i "s/up/down/g" /tmp/ports.json
|
|
sonic-cfggen -j /etc/sonic/init_cfg.json -j /tmp/buffers.json -j /tmp/qos.json -j /tmp/ports.json --print-data > /etc/sonic/config_db.json
|
|
fi
|
|
|
|
mkdir -p /etc/swss/config.d/
|
|
|
|
rm -f /var/run/rsyslogd.pid
|
|
|
|
supervisorctl start rsyslogd
|
|
|
|
supervisord_cfg="/etc/supervisor/conf.d/supervisord.conf"
|
|
chassis_cfg_file="/usr/share/sonic/virtual_chassis/default_config.json"
|
|
chassis_cfg_file_default="/etc/default/sonic-db/default_chassis_cfg.json"
|
|
host_template="/usr/share/sonic/templates/hostname.j2"
|
|
db_cfg_file="/var/run/redis/sonic-db/database_config.json"
|
|
db_cfg_file_tmp="/var/run/redis/sonic-db/database_config.json.tmp"
|
|
|
|
if [ -r "$chassis_cfg_file" ]; then
|
|
echo $(sonic-cfggen -j $chassis_cfg_file -t $host_template) >> /etc/hosts
|
|
else
|
|
chassis_cfg_file="$chassis_cfg_file_default"
|
|
echo "10.8.1.200 redis_chassis.server" >> /etc/hosts
|
|
fi
|
|
|
|
mkdir -p /var/run/redis/sonic-db
|
|
cp /etc/default/sonic-db/database_config.json /var/run/redis/sonic-db/
|
|
|
|
supervisorctl start redis-server
|
|
|
|
start_chassis_db=`sonic-cfggen -v DEVICE_METADATA.localhost.start_chassis_db -y $chassis_cfg_file`
|
|
if [[ "$HOSTNAME" == *"supervisor"* ]] || [ "$start_chassis_db" == "1" ]; then
|
|
supervisorctl start redis-chassis
|
|
python /usr/bin/chassis_db.py
|
|
fi
|
|
|
|
conn_chassis_db=`sonic-cfggen -v DEVICE_METADATA.localhost.connect_to_chassis_db -y $chassis_cfg_file`
|
|
if [ "$start_chassis_db" != "1" ] && [ "$conn_chassis_db" != "1" ]; then
|
|
cp $db_cfg_file $db_cfg_file_tmp
|
|
remove_chassisdb_config -j $db_cfg_file_tmp
|
|
cp $db_cfg_file_tmp $db_cfg_file
|
|
fi
|
|
|
|
|
|
/usr/bin/configdb-load.sh
|
|
|
|
supervisorctl start syncd
|
|
|
|
supervisorctl start portsyncd
|
|
|
|
supervisorctl start orchagent
|
|
|
|
supervisorctl start neighsyncd
|
|
|
|
supervisorctl start teamsyncd
|
|
|
|
supervisorctl start fpmsyncd
|
|
|
|
supervisorctl start teammgrd
|
|
|
|
supervisorctl start vrfmgrd
|
|
|
|
supervisorctl start portmgrd
|
|
|
|
supervisorctl start intfmgrd
|
|
|
|
supervisorctl start vlanmgrd
|
|
|
|
supervisorctl start zebra
|
|
|
|
supervisorctl start staticd
|
|
|
|
supervisorctl start buffermgrd
|
|
|
|
supervisorctl start nbrmgrd
|
|
|
|
supervisorctl start vxlanmgrd
|
|
|
|
supervisorctl start sflowmgrd
|
|
|
|
supervisorctl start natmgrd
|
|
|
|
supervisorctl start natsyncd
|
|
|
|
# Start arp_update when VLAN exists
|
|
VLAN=`sonic-cfggen -d -v 'VLAN.keys() | join(" ") if VLAN'`
|
|
if [ "$VLAN" != "" ]; then
|
|
supervisorctl start arp_update
|
|
fi
|