sonic-buildimage/device/accton/x86_64-accton_as5812_54x-r0/plugins/psuutil.py
Roy Lee 4d212debc7 [device][platform] add platform as5812-54x, accton. (#2889)
* Add new device accton_as5812_54x.
Signed-off-by: roy_lee <roy_lee@accton.com>

* Rename 5812's config.bcm.
Signed-off-by: roy_lee <roy_lee@accton.com>

* Change fan module to support lm-sensors.
Validate for thermal policy.
Signed-off-by: roy_lee <roy_lee@accton.com>

* Add bask reset and lpmode control of 6 QSFP ports.
Signed-off-by: roy_lee <roy_lee@accton.com>

* Get currect duty of fan for comparing. Instead of by stored duty from previous iteration.
Signed-off-by: roy_lee <roy_lee@accton.com>

* Roll back the mistakes to update mellanox submodules.
Signed-off-by: roy_lee <roy_lee@accton.com>

* Rollback for misoperation on submodule platform/p4/SAI-P4-BM.
Signed-off-by: roy_lee <roy_lee@accton.com>

* Change indexes of ports to start from 1, as them on the front panel.
Add low-power mode control of the transciever's eeprom, follows SFF-8436.
Signed-off-by: roy_lee <roy_lee@accton.com>
2019-05-28 22:44:32 -07:00

62 lines
1.6 KiB
Python
Executable File

#!/usr/bin/env python
#############################################################################
# Accton
#
# Module contains an implementation of SONiC PSU Base API and
# provides the PSUs status which are available in the platform
#
#############################################################################
import os.path
try:
from sonic_psu.psu_base import PsuBase
except ImportError as e:
raise ImportError (str(e) + "- required module not found")
class PsuUtil(PsuBase):
"""Platform-specific PSUutil class"""
def __init__(self):
PsuBase.__init__(self)
self.psu_path = "/sys/bus/i2c/devices/"
self.psu_presence = "/psu_present"
self.psu_oper_status = "/psu_power_good"
self.psu_mapping = {
1: "57-0038",
2: "58-003b",
}
def get_num_psus(self):
return len(self.psu_mapping)
def get_psu_status(self, index):
if index is None:
return False
status = 0
node = self.psu_path + self.psu_mapping[index]+self.psu_oper_status
try:
with open(node, 'r') as power_status:
status = int(power_status.read())
except IOError:
return False
return status == 1
def get_psu_presence(self, index):
if index is None:
return False
status = 0
node = self.psu_path + self.psu_mapping[index] + self.psu_presence
try:
with open(node, 'r') as presence_status:
status = int(presence_status.read())
except IOError:
return False
return status == 1