* Update the buffer size based on the latest excel Signed-off-by: Stephen Sun <stephens@mellanox.com> * Align the buffer configuration with the latest formula: - reduce redundant "*2" in formula - use port MTU for local sending the PFC frame and peer lossless MTU for peer sending lossless traffic Buffer pool size updated accordingly. Signed-off-by: Stephen Sun <stephens@mellanox.com>
18 lines
746 B
INI
18 lines
746 B
INI
# PG lossless profiles.
|
|
# speed cable size xon xoff threshold
|
|
10000 5m 49152 19456 29696 0
|
|
25000 5m 49152 19456 29696 0
|
|
40000 5m 49152 19456 29696 0
|
|
50000 5m 49152 19456 29696 0
|
|
100000 5m 50176 19456 30720 0
|
|
10000 40m 49152 19456 29696 0
|
|
25000 40m 51200 19456 31744 0
|
|
40000 40m 52224 19456 32768 0
|
|
50000 40m 53248 19456 33792 0
|
|
100000 40m 58368 19456 38912 0
|
|
10000 300m 56320 19456 36864 0
|
|
25000 300m 67584 19456 48128 0
|
|
40000 300m 78848 19456 59392 0
|
|
50000 300m 86016 19456 66560 0
|
|
100000 300m 123904 19456 104448 0
|