# Copyright (c) 2019 Mellanox Technologies
#
# Platform specific sensors config for SN3700C
################################################################################
# Temperature sensors
bus "i2c-2" "i2c-1-mux (chan_id 1)"
chip "mlxsw-i2c-*-48"
label temp1 "Ambient ASIC Temp"
ignore temp2
ignore temp3
ignore temp4
ignore temp5
ignore temp6
ignore temp7
ignore temp8
ignore temp9
ignore temp10
ignore temp11
ignore temp12
ignore temp13
ignore temp14
ignore temp15
ignore temp16
ignore temp17
ignore temp18
ignore temp19
ignore temp20
ignore temp21
ignore temp22
ignore temp23
ignore temp24
ignore temp25
ignore temp26
ignore temp27
ignore temp28
ignore temp29
ignore temp30
ignore temp31
ignore temp32
ignore temp33
bus "i2c-7" "i2c-1-mux (chan_id 6)"
chip "tmp102-i2c-*-49"
label temp1 "Ambient Fan Side Temp (air intake)"
chip "tmp102-i2c-*-4a"
label temp1 "Ambient Port Side Temp (air exhaust)"
bus "i2c-15" "i2c-1-mux (chan_id 6)"
chip "tmp102-i2c-15-49"
label temp1 "Ambient COMEX Temp"
# Power controllers
bus "i2c-5" "i2c-1-mux (chan_id 4)"
chip "tps53679-i2c-*-70"
label in1 "PMIC-1 PSU 12V Rail (in1)"
label in2 "PMIC-1 PSU 12V Rail (in2)"
label in3 "PMIC-1 ASIC 0.8V VCORE Rail (out)"
label in4 "PMIC-1 ASIC 1.2V Rail (out)"
label temp1 "PMIC-1 Temp 1"
label temp2 "PMIC-1 Temp 2"
label power1 "PMIC-1 ASIC 0.8V VCORE Rail Pwr (out)"
label power2 "PMIC-1 ASIC 1.2V Rail Pwr (out)"
label curr1 "PMIC-1 ASIC 0.8V VCORE Rail Curr (out)"
label curr2 "PMIC-1 ASIC 1.2V Rail Curr (out)"
chip "tps53679-i2c-*-71"
label in1 "PMIC-2 PSU 12V Rail (in1)"
label in2 "PMIC-2 PSU 12V Rail (in2)"
label in3 "PMIC-2 ASIC 3.3V Rail (out)"
compute in3 (1.5)*@, @/(1.5)
label in4 "PMIC-2 ASIC 1.8V Rail (out)"
label temp1 "PMIC-2 Temp 1"
label temp2 "PMIC-2 Temp 2"
label power1 "PMIC-2 ASIC 3.3V Rail Pwr (out)"
label power2 "PMIC-2 ASIC 1.8V Rail Pwr (out)"
label curr1 "PMIC-2 ASIC 3.3V Rail Curr (out)"
label curr2 "PMIC-2 ASIC 1.8V Rail Curr (out)"
bus "i2c-15" "i2c-1-mux (chan_id 6)"
chip "tps53679-i2c-*-58"
label in1 "PMIC-3 PSU 12V Rail (in1)"
label in2 "PMIC-3 PSU 12V Rail (in2)"
label in3 "PMIC-3 COMEX 1.8V Rail (out)"
label in4 "PMIC-3 COMEX 1.05V Rail (out)"
label temp1 "PMIC-3 Temp 1"
label temp2 "PMIC-3 Temp 2"
label power1 "PMIC-3 COMEX 1.8V Rail Pwr (out)"
label power2 "PMIC-3 COMEX 1.05V Rail Pwr (out)"
label curr1 "PMIC-3 COMEX 1.8V Rail Curr (out)"
label curr2 "PMIC-3 COMEX 1.05V Rail Curr (out)"
chip "tps53679-i2c-*-61"
label in1 "PMIC-4 PSU 12V Rail (in1)"
label in2 "PMIC-4 PSU 12V Rail (in2)"
label in3 "PMIC-4 COMEX 1.2V Rail (out)"
ignore in4
label temp1 "PMIC-4 Temp 1"
label temp2 "PMIC-4 Temp 2"
label power1 "PMIC-4 COMEX 1.2V Rail Pwr (out)"
ignore power2
label curr1 "PMIC-4 COMEX 1.2V Rail Curr (out)"
ignore curr2
# Power supplies
bus "i2c-4" "i2c-1-mux (chan_id 3)"
chip "dps460-i2c-*-58"
label in1 "PSU-2 220V Rail (in)"
ignore in2
label in3 "PSU-2 12V Rail (out)"
label fan1 "PSU-2 Fan 1"
ignore fan2
ignore fan3
label temp1 "PSU-2 Temp 1"
label temp2 "PSU-2 Temp 2"
label temp3 "PSU-2 Temp 3"
label power1 "PSU-2 220V Rail Pwr (in)"
label power2 "PSU-2 12V Rail Pwr (out)"
label curr1 "PSU-2 220V Rail Curr (in)"
label curr2 "PSU-2 12V Rail Curr (out)"
set in3_lcrit in3_crit * 0.662
set in3_min in3_crit * 0.745
set in3_max in3_crit * 0.952
chip "dps460-i2c-*-59"
label in1 "PSU-1 220V Rail (in)"
ignore in2
label in3 "PSU-1 12V Rail (out)"
label fan1 "PSU-1 Fan 1"
ignore fan2
ignore fan3
label temp1 "PSU-1 Temp 1"
label temp2 "PSU-1 Temp 2"
label temp3 "PSU-1 Temp 3"
label power1 "PSU-1 220V Rail Pwr (in)"
label power2 "PSU-1 12V Rail Pwr (out)"
label curr1 "PSU-1 220V Rail Curr (in)"
label curr2 "PSU-1 12V Rail Curr (out)"
set in3_lcrit in3_crit * 0.662
set in3_min in3_crit * 0.745
set in3_max in3_crit * 0.952
# Chassis fans
chip "mlxreg_fan-isa-*"
label fan1 "Chassis Fan Drawer-1 Tach 1"
label fan2 "Chassis Fan Drawer-1 Tach 2"
label fan3 "Chassis Fan Drawer-2 Tach 1"
label fan4 "Chassis Fan Drawer-2 Tach 2"
label fan5 "Chassis Fan Drawer-3 Tach 1"
label fan6 "Chassis Fan Drawer-3 Tach 2"
label fan7 "Chassis Fan Drawer-4 Tach 1"
label fan8 "Chassis Fan Drawer-4 Tach 2"
# Miscellaneous
chip "*-virtual-*"
ignore temp1