sonic-buildimage/device/arista/x86_64-arista_7170_64c/sensors.conf
Nazar Tkachuk be145b613c
[Arista] Rename chip in sensors.conf for 7170 platform (#6026)
Rename chip name dps1900-i2c-X-58 to pmbus-i2c-X-58 in sensors.conf for Arista 7170 due to latest updates for Arista driver submodules #5686. After these updates adapter dps1900 was renamed and sensors.conf file is not applied properly. Issue was observed started from BFN SONiC image 16.

Signed-off-by: Nazar Tkachuk <nazarx.tkachuk@intel.com>
2020-12-01 15:57:31 -08:00

60 lines
1.5 KiB
Plaintext

# libsensors configuration file for DCS-7260CX3-64
# ------------------------------------------------
bus "i2c-6" "SCD 0000:06:00.0 SMBus master 0 bus 5"
bus "i2c-7" "SCD 0000:06:00.0 SMBus master 0 bus 6"
bus "i2c-8" "SCD 0000:06:00.0 SMBus master 0 bus 7"
bus "i2c-81" "SCD 0000:ff:0b.3 SMBus master 0 bus 0"
bus "i2c-93" "SCD 0000:ff:0b.3 SMBus master 3 bus 0"
bus "i2c-96" "SCD 0000:ff:0b.3 SMBus master 3 bus 3"
chip "max6658-i2c-8-4c"
label temp1 "Temp sensor near ASIC"
set temp1_max 100
set temp1_crit 110
set temp1_min -55
set temp2_max 100
set temp2_crit 110
set temp2_min -55
ignore temp2
chip "pmbus-i2c-6-58"
label temp1 "PSU1 primary hotspot temp"
label temp2 "PSU1 inlet temp"
label temp3 "PSU1 exhaust temp"
# setting maximum and critical thresholds is not supported for this psu
# fault and warning limits defined internally by hardware
ignore fan2
ignore fan3
chip "pmbus-i2c-7-58"
label temp1 "PSU2 primary hotspot temp"
label temp2 "PSU2 inlet temp"
label temp3 "PSU2 exhaust temp"
# setting maximum and critical thresholds is not supported for this psu
# fault and warning limits defined internally by hardware
ignore fan2
ignore fan3
chip "max6658-i2c-81-4c"
label temp1 "Rear air temp1"
label temp2 "Rear air temp2"
set temp1_max 70
set temp1_crit 80
set temp1_min -55
set temp2_max 70
set temp2_crit 80
set temp2_min -55
chip "lm73-i2c-96-48"
label temp1 "Front air temp"
set temp1_max 65