# libsensors configuration file for DCS-7050QX-32S # ------------------------------------------------ # bus "i2c-2" "SCD SMBus master 0 bus 0" bus "i2c-3" "SCD SMBus master 0 bus 1" bus "i2c-5" "SCD SMBus master 0 bus 3" bus "i2c-6" "SCD SMBus master 0 bus 4" bus "i2c-7" "SCD SMBus master 0 bus 5" chip "k10temp-pci-00c3" label temp1 "Cpu temp sensor" chip "max6658-i2c-2-4c" label temp1 "Board temp sensor" set temp1_max 55 set temp1_crit 70 label temp2 "Front panel temp sensor" set temp2_max 65 set temp2_crit 75 chip "max6658-i2c-3-4c" label temp1 "Cpu board temp sensor" set temp1_max 75 set temp1_crit 80 label temp2 "Back panel temp sensor" set temp2_max 75 set temp2_crit 80 chip "pmbus-i2c-3-4e" label temp1 "Power controller 1 sensor 1" label temp2 "Power controller 1 sensor 2" chip "pmbus-i2c-7-4e" label temp1 "Power controller 2 sensor 1" label temp2 "Power controller 2 sensor 2" chip "pmbus-i2c-6-58" label temp1 "Power supply 1 hotspot sensor" label temp2 "Power supply 1 inlet temp sensor" label temp3 "Power supply 1 sensor" chip "pmbus-i2c-5-58" label temp1 "Power supply 2 hotspot sensor" label temp2 "Power supply 2 inlet temp sensor" label temp3 "Power supply 2 sensor"