# libsensors configuration file for DCS-7050CX3-32S # ------------------------------------------------ # bus "i2c-2" "SCD 0000:02:00.0 SMBus master 0 bus 0" bus "i2c-11" "SCD 0000:02:00.0 SMBus master 1 bus 1" bus "i2c-13" "SCD 0000:02:00.0 SMBus master 1 bus 3" bus "i2c-14" "SCD 0000:02:00.0 SMBus master 1 bus 4" chip "k10temp-pci-00c3" label temp1 "Cpu temp sensor" chip "max6658-i2c-2-4c" label temp1 "Cpu board temp sensor" set temp1_max 75 set temp1_crit 80 label temp2 "Back panel temp sensor" set temp2_max 75 set temp2_crit 85 chip "max6658-i2c-11-4c" label temp1 "Board temp sensor" set temp1_max 75 set temp1_crit 85 label temp2 "Front panel temp sensor" set temp2_max 60 set temp2_crit 65 chip "pmbus-i2c-13-58" label temp1 "Power supply 1 hotspot sensor" label temp2 "Power supply 1 inlet temp sensor" label temp3 "Power supply 1 sensor" chip "pmbus-i2c-14-58" label temp1 "Power supply 2 hotspot sensor" label temp2 "Power supply 2 inlet temp sensor" label temp3 "Power supply 2 sensor"