#!/usr/bin/env python import swsssdk import time def enable_counter_group(db, name): info = {} info['FLEX_COUNTER_STATUS'] = 'enable' db.mod_entry("FLEX_COUNTER_TABLE", name, info) def enable_counters(): db = swsssdk.ConfigDBConnector() db.connect() enable_counter_group(db, 'PORT') enable_counter_group(db, 'RIF') enable_counter_group(db, 'QUEUE') enable_counter_group(db, 'PFCWD') enable_counter_group(db, 'PG_WATERMARK') enable_counter_group(db, 'QUEUE_WATERMARK') def get_uptime(): with open('/proc/uptime') as fp: return float(fp.read().split(' ')[0]) def main(): # If the switch was just started (uptime less than 5 minutes), # wait for 3 minutes and enable counters # otherwise wait for 60 seconds and enable counters uptime = get_uptime() if uptime < 300: time.sleep(180) else: time.sleep(60) enable_counters() if __name__ == '__main__': main()