# libsensors configuration file for DCS-7050SX3-48YC8 # --------------------------------------------------- # bus "i2c-8" "SCD 0000:02:00.0 SMBus master 0 bus 0" bus "i2c-9" "SCD 0000:02:00.0 SMBus master 0 bus 1" bus "i2c-10" "SCD 0000:02:00.0 SMBus master 0 bus 2" bus "i2c-72" "SCD 0000:00:09.0 SMBus master 0 bus 2" chip "k10temp-pci-00c3" label temp1 "Cpu temp sensor" chip "pmbus-i2c-8-58" label temp1 "Power supply 1 hotspot sensor" label temp2 "Power supply 1 inlet temp sensor" label temp3 "Power supply 1 sensor" chip "pmbus-i2c-9-58" label temp1 "Power supply 2 hotspot sensor" label temp2 "Power supply 2 inlet temp sensor" label temp3 "Power supply 2 sensor" chip "max6658-i2c-72-4c" label temp1 "Board temp sensor" set temp1_max 75 set temp1_crit 85 label temp2 "Front panel temp sensor" set temp2_max 75 set temp2_crit 85 chip "tmp464-i2c-10-48" label temp1 "Switch Card temp sensor" set temp1_max 100 set temp1_crit 110 label temp2 "Front-panel temp sensor" set temp2_max 65 set temp2_crit 75 label temp3 "Front PCB temp sensor" set temp3_max 75 set temp3_crit 80 ignore temp4 ignore temp5 ignore temp6 ignore temp7 ignore temp8 ignore temp9