From 45587a19ab4b69e5d1ed84d9910a6b89d0fc5520 Mon Sep 17 00:00:00 2001 From: Kevin Wang Date: Thu, 10 Jan 2019 07:22:31 +0200 Subject: [PATCH] Suspend thermal control by default Suspend thermal control and set the default fan speed to 60% Signed-off-by: Kevin Wang --- usr/usr/bin/hw-management-thermal-control.sh | 5 +++-- usr/usr/bin/hw-management.sh | 1 + 2 files changed, 4 insertions(+), 2 deletions(-) diff --git a/usr/usr/bin/hw-management-thermal-control.sh b/usr/usr/bin/hw-management-thermal-control.sh index c7274a6..4c5438f 100755 --- a/usr/usr/bin/hw-management-thermal-control.sh +++ b/usr/usr/bin/hw-management-thermal-control.sh @@ -116,6 +116,7 @@ max_ports=${5:-$max_ports_def} # Local constants pwm_noact=0 pwm_max=1 +pwm_def_rpm=153 pwm_max_rpm=255 max_amb=120000 untrusted_sensor=0 @@ -893,8 +894,8 @@ disable_zones_max_pwm() { fi fi done - echo $pwm_max_rpm > $pwm - log_action_msg "Set fan speed to maximum" + echo $pwm_def_rpm > $pwm + log_action_msg "Set fan speed to 60% percent" } trip_points_num=4 diff --git a/usr/usr/bin/hw-management.sh b/usr/usr/bin/hw-management.sh index 9214a9f..c8261a3 100755 --- a/usr/usr/bin/hw-management.sh +++ b/usr/usr/bin/hw-management.sh @@ -565,6 +565,7 @@ do_start() echo $asic_bus > $config_path/asic_bus connect_platform + echo 1 > $config_path/suspend $THERMAL_CONTROL $thermal_type $max_tachos $max_psus& } -- 1.9.1