#!/bin/bash query_retry_count_max="10" required_fw_version="13.1200.0116" fw_file=/etc/mlnx/fw-SPC.mfa run_or_fail() { $1 if [[ $? != 0 ]]; then echo $1 failed exit 1 fi } # wait until devices will be available query_retry_count="0" mlxfwmanager --query > /dev/null while [[ (${query_retry_count} -lt ${query_retry_count_max}) && ($? -ne "0") ]]; do sleep 1 query_retry_count=$[${query_retry_count}+1] mlxfwmanager --query > /dev/null done run_or_fail "mlxfwmanager --query" > /tmp/mlnxfwmanager-query.txt # get current firmware version found_fw=false for word in `cat /tmp/mlnxfwmanager-query.txt` do if [[ ${found_fw} == true ]]; then fw_version=${word} break fi if [[ ${word} == FW ]]; then found_fw=true fi done if [[ -z ${fw_version} ]]; then echo "Could not retreive current FW version." exit 1 fi if [[ ${required_fw_version} == ${fw_version} ]]; then echo "Mellanox firmware is up to date." else echo "Mellanox firmware required version is ${required_fw_version}. Installing compatible version..." run_or_fail "mlxfwmanager -i ${fw_file} -u -f -y" # exit from here so that syncd service will restart exit 0 fi