However in SAI 3.7 default behaviout got changes to 128 Group and 128
Memeber each.
This change is to make sure we are using same ECMP Group/Memeber Per
Group for 3.7 also so that behaviour is consistent.
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
as needed by SAI 3.7 and above. Without this change
Warmboot fails from 3.5 to 3.7 as Braodcoam Datastructure
gets corrupted after warm-boot.
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
- Skip thermalctld in DellEMC S6000, S6100, Z9100 and Z9264 platforms.
- Change the return type of thermal Platform APIs in DellEMC S6000, S6100, Z9100 and Z9264 platforms to 'float'.
* Remove the divide by 4 operation to the under the hood SAI
This is to avoid the need and thus the confusion for application program to know
the mmu internal architecture
This change must have support from SAI change to reach the correct
config
Signed-off-by: Wenda <wenni@microsoft.com>
* Relegate the divide by 4 operation to the under the hood SAI for egress
lossless pool
Extend to 7060 and 6100
Signed-off-by: Wenda <wenni@microsoft.com>
* Add more TH/TH2 hwskus
Signed-off-by: Wenda Ni <wenni@microsoft.com>
* Update config test
Signed-off-by: Wenda Ni <wenni@microsoft.com>
* Add TH2 ingress lossy profile
Signed-off-by: Wenda Ni <wenni@microsoft.com>
* Move the divide by 4 operation to SAI internal
Signed-off-by: Wenda Ni <wenni@microsoft.com>
* [bcm SAI] Upgrade Broadcom SAI to version 3.5.3.1-15
- Broadcom SAI 3.5 GA release 20190924.
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
* [dell/Z9100] Fix for optics not detected in fanout mode
This commit fixes the issue of optics not detected
error while running sfputil show eeprom command. The root
casuse was the value of port index from port_config.ini for
fan out scenario. The port index should be starting from 0
and not 1. Platform cpld registers are assuming the port
numbers to start from 0 (lowermost bit), sfputils.py uses this
port number in get_presence function. Since the indexing passed
is wrong the optics was not detected and gave SFP EEPROM not
detected message.
Signed-off-by: Harish Venkatraman <Harish_Venkatraman@Dell.com>
* [dell/z9100] Fix for optics not detected in fanout mode
This commit fixes the issue of optics not detected error
while running sfputil show eeprom command. The root cause
was wrong port_index in fan out scenarios. Earlier fix of
changing the port_config.ini is reverted and changes made
in z9100 platform specific sfputil.py file. The port number
is decrement and tested for both 100G and 50G fanout cases.
Tested for the following show commands and test was succesful
show interfaces status, show interfaces transceiver eeprom,
show interfaces transceiver lpmode, show interface tranceiver
presence.
Signed-off-by: Harish Venkatraman <Harish_Venkatraman@Dell.com>
* QoS config change: 1) DSCP mapping; 2) link pg/queue 6 to lossy buffer;
3) redistribute scheduler
Signed-off-by: Wenda <wenni@microsoft.com>
* Add scheduling weight to queue 2
Signed-off-by: Wenda <wenni@microsoft.com>
* Link pg/queue 2 to lossy buffer
Signed-off-by: Wenda <wenni@microsoft.com>
* Update the pg headroom for a7060-D48C8 50G
Signed-off-by: Wenda <wenni@microsoft.com>
* Update config gen test for qos
Signed-off-by: Wenda <wenni@microsoft.com>
* Update pg headroom size, and update egress lossy pool size accordingly
Signed-off-by: Wenda <wenni@microsoft.com>
* Update headroom pool size; Update ingress service pool and egress lossy
pool sizes accordingly;
Signed-off-by: Wenda <wenni@microsoft.com>
* a7260: update headroom pool size; Update ingress service pool and egress lossy pool sizes accordingly;
Signed-off-by: Wenda <wenni@microsoft.com>
* Update config gen test for buffer
Signed-off-by: Wenda <wenni@microsoft.com>
dell_ich module fails to load sometimes due to the failure of pci_get_drvdata().
This function is responsible for fetching INTEL PCI related memory handle in kernel. This is implemented in lpc_ich kernel module.
Due to race in addition/deletion of kernel modules, sometimes lpc_ich loads after dell_ich.
Because of this behaviour dell_ich module fails to load.
Fixed by addding dependency between modules.
Removed i2c_mux_gpio module from blacklist entry as it is not the original root case of this issue.
This commit has the forward porting of changes from 20180330
to master. Unit tested by checking the broadcom registers
for the values. The values in hardware reflect the correct values
except for TC to PFC priority group map values. Master branch values
for TC to PFC priority group map for both z9100 and s6100 in incorrect,
I have a build of Oct 12 master and the values are correct in
that build.
Signed-off-by: Harish Venkatraman <Harish_Venkatraman@Dell.com>
* xcvrd OIR support for Dell S6100/Z9100 switches
Introduced check_interrupts function to handle missed interrupts.
port_dict updated and returned for appropriate OIR events.
Added support for both S6100/Z9100 switches.
* Revamped sfputil.py for PEP8 Standards
* Unify qos config with qos_config.j2 template
Signed-off-by: Wenda <wenni@microsoft.com>
* Change 7050 to use qos config template
Signed-off-by: Wenda <wenni@microsoft.com>
modified: device/arista/x86_64-arista_7050_qx32/Arista-7050-QX32/qos.json.j2
modified: device/arista/x86_64-arista_7050_qx32s/Arista-7050-QX-32S/qos.json.j2
* Change a7060, a7260, s6000, s6100, z9100 to use qos config template
Signed-off-by: Wenda <wenni@microsoft.com>
* Change mlnx devices to use qos config template
Signed-off-by: Wenda <wenni@microsoft.com>
modified: ../../../mellanox/x86_64-mlnx_msn2100-r0/ACS-MSN2100/qos.json.j2
modified: ../../../mellanox/x86_64-mlnx_msn2410-r0/ACS-MSN2410/qos.json.j2
modified: ../../../mellanox/x86_64-mlnx_msn2700-r0/ACS-MSN2700/qos.json.j2
modified: ../../../mellanox/x86_64-mlnx_msn2700-r0/Mellanox-SN2700-D48C8/qos.json.j2
* Change barefoot devices to use qos config template
Signed-off-by: Wenda <wenni@microsoft.com>
modified: barefoot/x86_64-accton_wedge100bf_32x-r0/montara/qos.json.j2
modified: barefoot/x86_64-accton_wedge100bf_65x-r0/mavericks/qos.json.j2
* Change accton as7212 to use qos config template
Signed-off-by: Wenda <wenni@microsoft.com>
modified: accton/x86_64-accton_as7212_54x-r0/AS7212-54x/qos.json.j2
* Apply PORT_QOS_MAP to active ports only
Signed-off-by: Wenda <wenni@microsoft.com>
* Update qos config test with qos_config.j2 template
Signed-off-by: Wenda <wenni@microsoft.com>
* Update sample output of qos-dell6100.json
Signed-off-by: Wenda <wenni@microsoft.com>
* Remove generating the default port name and index list, i.e., remove the generate_port_lists macro, because PORT is always defined
Signed-off-by: Wenda <wenni@microsoft.com>
* Include pfc_to_pg_map according to platform asic type obtained from
/etc/sonic/sonic_version.yml rather than specifying per hwsku
Signed-off-by: Wenda Ni <wenni@microsoft.com>
* Customize TC_TO_PRIORITY_GROUP_MAP and
PFC_PRIORITY_TO_PRIORITY_GROUP_MAP for barefoot
Signed-off-by: Wenda <wenni@microsoft.com>
* Unify PFC_PRIORITY_TO_PRIORITY_GROUP_MAP: remove "0":"0", "1":"1" as
these two pgs do not generate PFC frames.
Signed-off-by: Wenda <wenni@microsoft.com>
* [updategraph] add support to use preset config instead of default minigraph
* Fix variable case
* Remove default minigraph case
* Remove default minigraphs and add default_sku files
This commit updates the shared headroom value for z9100
T0 and T1 profile based on the ratio. The ratio is derived
from the 40G broadcom recommended XL Sheet.
Unit tested the above configuration by dumping the registers
for the shared headroom. The shared headroom values in registers
reflects the correct new values for both T1 and T0.
Signed-off-by: Harish Venkatraman <Harish_Venkatraman@dell.com>
* First part of skipping not used port for qos configuration
* Use active ports only to set QoS parameters for 6100
* Add a test for qos.json.j2
* Add a test for Dell S6100 buffers.json template
* Update submodulre
This commit adds new code to support z9100 PFC T1 support with
broadcom recommended MMU settings for PFC feature.
Unit tested the setting by loading sonic-broadcom.bin and checking
the hardware for the values from the JSON file. Added the config.bcm
file th-z9100-32x100G.config.bcm to this folder and updated the
sai.profile file to point to hwsku directory. sai.profile now
points to /usr/share/sonic/hwsku/th-z9100-32x100G.config.bcm
Signed-off-by: Harish Venkatraman <Harish_Venkatraman@dell.com>
This commit adds new code to support z9100 PFC T0 support with
broadcom recommended MMU settings for PFC feature.
Unit tested the setting by loading sonic-broadcom.bin and checking
the hardware for the values from the JSON file. The T0 configs supports
fan-out of 100G ports on Z9100. Added new config.bcm for fanout of 100G
ports and tested the fanout by sending traffic using bcmcmd, new config.bcm
file will be copied to /usr/share/sonic/hwsku/th-z9100-8x100-48x50G.config.bcm.
The sai.profile file is updated to point to hwsku directory.
Signed-off-by: Harish Venkatraman <Harish_Venkatraman@dell.com>
1. "make target/sonic-broadcom.raw" will create the compressed dd'able image.
2. This will also update the grub config files (device/dell/*/nos_to_sonic_grub.cfg) with the image versions.
[swss]: Generate config files for Everflow and IPinIP from minigraph
- Add Everflow DST IP to minigraph file
- Extend minigraph.py to support Everflow
- Add templates file for Everflow and IPinIP configuration
- Add config.sh for swss docker to generate config files