Signed-off-by: Yong Zhao yozhao@microsoft.com
Why I did it
This PR aims to fix an issue (#10088) by enhancing the script memory_checker.
Specifically, if container is not created successfully during device is booted/rebooted, then memory_checker do not need check its memory usage.
How I did it
In the script memory_checker, a function is added to get names of running containers. If the specified container name is not in current running container list, then this script will exit without checking its memory usage.
How to verify it
I tested on a lab device by following the steps:
Stops telemetry container with command sudo systemctl stop telemetry.service
Removes telemetry container with command docker rm telemetry
Checks whether the script memory_checker ran by Monit will generate the syslog message saying it will exit without checking memory usage of telemetry.
example:
├── folderA
│ ├── fileA (skip vstest)
│ ├── fileB
│ └── fileC
If we want to skip vstest when changing /folderA/fileA, and not skip vstest when changing fileB or fileC.
vstest-include:
^folderA/fileA
vstest-exclude:
^folderA
Why I did it
S5212F - Platform API 2.0 changes
S5224F - Platform API 2.0 changes
How I did it
Implemented the functional API's needed for Platform API 2.0
Added media_settings.json, pcie.yaml, platform.json, system_health_monitoring_config.json files.
How to verify it
Used the API 2.0 test suite to validate the test cases.
Why I did it
This change adds the support for Arista 7060dx5_64s and 7060px5_64s
How I did it
How to verify it
We verified the platform driver is working and the ports are up on 7060dx5_64s and 7060px5_64s.
Add most configuration files for the DCS-7050PX4-32S and DCS-7050DX4-32S.
This review only contains platform configuration files, dataplane ones will follow in future change.
Co-authored-by: Zhi Yuan (Carl) Zhao <zyzhao@arista.com>
- Why I did it
Recent change to delay PMON service in case of fast/warm reboot introduce an issue when restarting only SWSS service after fast/warm reboot for Nvidia platform.
Since the timer is triggered only when the system boot, in a scenario when the system is after a fast/warm reboot and the user restart SWSS service, as part of syncd.sh script, PMON service will stop but the timer will not start again.
- How I did it
On syncd.sh script, in case of fast/warm indication, check if pmon.timer is running.
If it is running it means we are at the first boot and continue normally.
If it is not running, meaning the service was restarted, start the timer to keep the system behavior consistent.
- How to verify it
Run fast/warm reboot.
service swss restart.
Observe PMON service starting.
Signed-off-by: Shlomi Bitton <shlomibi@nvidia.com>
Why I did it
The docker storage driver vfs is not a good option for build, it uses the “deep copy” when building a new layer, leads to lower performance and more space used on disk than other storage drivers.
A better docker storage driver is the default one overlay2, it is a modern union filesystem.
#### Why I did it
SSHD keepalive timeout feature not enabled on sonic.
#### How I did it
Enable SSHD keepalive timeout feature by set ClientAliveCountMax to 1.
#### How to verify it
Pass All E2E test case.
Manually test with following steps:
1. Change config and restart sshd
2. Connect a ssh with -vvv option to show debug message
3. Get running ssh by command and stop it:
```
azureuser@liuh-dev-vm-02:~$ ps -auxww | grep vvv
azureus+ 1614153 0.0 0.0 12244 6004 pts/1S+ 15:48 0:00 ssh admin@10.250.0.101 -vvv
azureus+ 1615570 0.0 0.0 8168 2424 pts/3S+ 15:49 0:00 grep --color=auto vvv
azureuser@liuh-dev-vm-02:~$ kill -Stop 1614153
```
4. Check TCP status from server side with ss command:
https://man7.org/linux/man-pages/man8/ss.8.html
```
admin@vlab-01:~$ ss | grep -i ssh
tcp ESTAB 0 010.250.0.101:ssh 10.250.0.1:58150
tcp FIN-WAIT-2 0 010.250.0.101:ssh 10.250.0.1:58164
tcp ESTAB 0 010.250.0.101:ssh 10.250.0.1:57978
```
FIN-WAIT-2 means server already terminate the connection and wait for client response:
https://kb.iu.edu/d/ajmi
. FIN-WAIT-2 <-- <SEQ=300><ACK=101><CTL=ACK> <-- CLOSE-WAIT
5. Check again later will show the session been complete closed:
```
admin@vlab-01:~$ ss | grep -i ssh
tcp ESTAB 0 010.250.0.101:ssh 10.250.0.1:58150
tcp ESTAB 0 010.250.0.101:ssh 10.250.0.1:57978
```
Why I did it
Added support for the device Z9432F
How I did it
Implemented the support for the platform Z9432F
Switch Vendor: DellEMC
Switch SKU: Z9432F-ON
ASIC Vendor: Broadcom
SONiC Image: sonic-broadcom.bin
Why I did it
To address internal build failures where the cable len for some of the skus is set to 300m for all tiers.
How I did it
For the buffers test, generate a new output file based off the original expected output with CABLE_LENGTH table updated to use 300m. In the comparison logic, compare against each of the expected output files and if any matches, the testcase is set to pass
Signed-off-by: Neetha John <nejo@microsoft.com>
* 48cccb4 2022-06-13 | do not use sai_query_api_version if vendor sai does not support in VendorSai.cpp (#1064) (HEAD, origin/master, origin/HEAD) [Guohan Lu]
* 9b0f773 2022-06-13 | [vslib]: Fixbug in cleanup MACsec device (#1059) [Ze Gan]
* cdf9427 2022-06-11 | No sai api version check if vendor sai does not support (#1063) (HEAD, origin/master, origin/HEAD) [Guohan Lu]
* 3964cf1 2022-06-09 | [counter] Fix port flex counter (#1052) [Junhua Zhai]
* 2231b7a 2022-06-03 | Purge package sonic-db-cli which depends on libswsscommon (#1057) [Qi Luo]
* 7aa09b9 2022-06-01 | Set PR diff code coverage threshold to 80% (#1039) [Kamil Cudnik]
* 66a29bc 2022-05-18 | [syncd] Use vendor SAI instead of direct SAI api (#1042) [Kamil Cudnik]
* 564bea7 2022-05-18 | [ci] Paralize azure pipeline (#1040) [Shilong Liu]
* 57ed180 2022-05-17 | [configure.ac] implement SAI API version check (#1000) [Stepan Blyshchak]
* 8894dc7 2022-05-17 | vslib: add support for read-only port capabilities (#1038) [Dante (Kuo-Jung) Su]
* 42af975 2022-04-29 | [vslib]: Update packet number of MACsec SA at runtime (#1007) [Ze Gan]
Signed-off-by: Guohan Lu <lguohan@gmail.com>
This fixes the build for armhf to be able to use '/device///installer.conf' files. Specifically, armhf needs support to be able to change the size of /var/log/ directory. It is hardcoded to 512 bytes on all armhf platforms currently. This change will allow any armhf platform to be able to use an installer.conf file to customize the installed image.
Why I did it
The dhcp_graph_url used by internal service is always set as "N/A". So we can make the updategraph logic short.
How I did it
Shorten 'if statement' logic for /tmp/dhcp_graph_url
29503ab [portchannel] Added ACL/PBH binding checks to the port before getting added to portchannel (#2151)
ac89489 Modify override testcase to cover PORT admin_status (#2165)
d7953d2 [GCU] Validate peer_group_range ip_range are correct (#2145)
aa81b97 [auto-ts] add memory check (#2116)
b370290 support new interface types CR8/SR8/KR8/LR8 which are brougnt by SAI V.1.10.2 (#2167)
87fc0a4 [scripts/fast-reboot] Add option to include ssd-upgrader-part boot option with SONiC partition (#2150)
90abc07 [config reload] Fix invalid rstrip. (#2157)
fac1769 Accept 0 for queue and dscp (#2162)
* [Tunnel PFC] Tests for adding property 'sai_remap_prio_on_tnl_egress'
Add tests for adding property 'sai_remap_prio_on_tnl_egress', this
property should only be added in dual tor environment.
Test done:
Run test test_j2files.py
Co-authored-by: richardyu <richardyu@contoso.com>
Why I did it
Provide fix for comment: https://github.com/Azure/sonic-buildimage/pull/10475/files#r847753187;
Move laoding database config to application code instead of portconfig as portconfig is used as a library.
#10581 was raised for this fix, but had to be reverted due to issue with multi-asic platform.
How I did it
Remove try exception handing from portconfig.py during config_db intialization.
Move loading of database config to application that uses portconfig.py.
How to verify it
unit-test passes.
Verified that it does not cause issue during boot up of multi-asic VS image.
Verified that config_db generation was successful in multi-asic VS.
Why I did it
Make reset didn't clean-up all fsroot folders.
How I did it
Remove all fsroot folders used during build.
How to verify it
Run local build and local make reset:
sudo mkdir fsroot-test
sudo touch fsroot-test/foo
make reset
(Without this change, make reset cannot remove fsroot-foo, with the change, the repo become clean after make reset.)
Signed-off-by: Ying Xie ying.xie@microsoft.com
- Why I did it
"import sonic_platform" takes about 600ms ~ 1000ms, it is kind of slow. After this optimization, the time is about 100ms. The benefit is that those CLIs which does not need the slow import sentence would be faster than before.
- How I did it
Find slow import and call them when need.
- How to verify it
Measure the import time.
- Why I did it
To include latest fixes:
1. Warmboot | When trying to reconfigure the Flex Parser header and Flex transition parameters after ISSU, the switch will returned an error even if the configuration was identical to that done before performing the ISSU.
2. Link Up | When toggling many ports of the Spectrum devices while raising 10GbE link up and link maintenance is enabled, the switch may get stuck and may need to be rebooted.
3. Shared buffer | While moving from lossless to lossy while shared headroom was used, reduction of the shared headroom can only be done prior to pool type change and when shared headroom is not utilized.
- How I did it
Updated SDK submodule along with the relevant Makefiles
- How to verify it
Build an image and run tests from "sonic-mgmt".
Signed-off-by: Volodymyr Samotiy <volodymyrs@nvidia.com>
- Why I did it
1. SN2201 sai profile needs to be updated according to the latest hardware.
2. In the reboot script, need to use the common symbol link of the power_cycle sysfs instead of directly accessing it due to SN2201 sysfs is different than other platforms.
3. echo 1 > $SYSFS_PWR_CYCLE will trigger the reboot immediately, the following sleep 3 and echo 0 > $SYSFS_PWR_CYCLE will never be executed, can be removed.
- How I did it
1. Replace the SN2201 sai profile with the latest one.
2. In the platform_reboot script, replace the direct sysfs path with the symbol link path.
3. Remove the redundant code from platform_reboot
- How to verify it
Perform reboot on all the Nvidia platforms, and check all can be rebooted successfully.
Signed-off-by: Kebo Liu <kebol@nvidia.com>
* [BGP]Adding configuration knob to allow advertise Loopback ipv6 /128 prefix
By default when IPv6 address is configured with /128 as subnet mask in Loopback0 interface, it will be advertised as prefix with /64 subnet.
To control this behavior a new field 'bgp_adv_lo_prefix_as_128' is introduced in DEVICE_METADATA table which when set to true will advertise prefix with /128 subnet as it is.
Why I did it
As part of PCBB changes, we need to enable 2 extra lossless queues. The changes in this PR are done to adjust only the reserved sizes on Th2 for the additional 2 lossless queues
Calculations are done based on 40 downlinks for T1 and 16 uplinks for dual ToR
How to verify it
Verified that the rendering works fine on Th2 dut
Unit tests have been updated to reflect the modified buffer sizes when pcbb is enabled. There are existing testcases that will test the original buffer sizes when pcbb is disabled. With these changes, was able to build sonic-config-engine wheel successfully
Signed-off-by: Neetha John <nejo@microsoft.com>
Why I did it
Some PR test are timing out on T1-lag kvm test.
How I did it
Increase the timeout to 5 hours.
How to verify it
Test on this PR.
Signed-off-by: Ying Xie ying.xie@microsoft.com
* [Tunnel PFC] Add property for tunnel PFC
Replace the config.bcm file with j2 template file
- Add 'sai_remap_prio_on_tnl_egress=1' property when device metadata local
- Host subtype is 'dualtor'
- Change sai.profile foe the new config.bcm.j2