Microsoft ADO (25266920)
sonic-mgmt xoff test was failing for [100g,120km]. Needed to update total headroom pool size when 100G line card is used as T2 uplink.
This size was calculated assuming 100g is used for downlink so cable length was 2km whereas it can also be used for uplink (cable length - 120km). so we need to do calculation based on 120km not 2km. Although it will be some wastage for 2km scenario but it should cover both cases.
Why I did it
Update the platform_reboot of Nokia Platform IXR-7250E-36x400G to displays the correct reboot-cause history when reboot from supervisor card.
Work item tracking
Microsoft ADO (number only):
How I did it
Modify the platform_reboot script to copy the correct reboo-cause.txt file from NDK to the /host/reboot-cause directory at the down cycle when the reboot is issued from Supervisor (for both reboot right after install a new image and normal reboot)
Signed-off-by: mlok <marty.lok@nokia.com>
Co-authored-by: Marty Y. Lok <76118573+mlok-nokia@users.noreply.github.com>
* Updated default ECN settings for T2 chassis (#14388)
Why I did it
Update ECN settings for T2 chassis
How I did it
Updated qos config file to load these settings during switch bootup
How to verify it
Verified on line card on T2 chassis
* Fix for test failures
* Test case failures
* test case fix
Why I did it
Update cable length for uplink/downlink ports for chassis and and update PG/pool headroom size accordingly.
Work item tracking
17880812
How I did it
Updated cable length as well as buffer config in HWSKU files.
Why I did it
When reboot the chassis by issuing "sudo reboot" on Supervisor card. The internal midplane communication xe0 should be shutdown to avoid double reboot on the linecard.
Added a udev link rule to disable the autoneg on AMD xgbe port Xe0 and Xe1 and make the setting in sync with the peer Broadcom greyhound ports.
How I did it
Modify the Nokia-7250IXRE specific reboot script on the Supervisor card to shutdown the internal interface xe0. Also move reboot linecard code to the top of the script to make sure the notification has been send to Linecard before shutdown the xe0 interface.
Introduced a new rule 80-net-by-driver.link to disable the autoneg on the AMD size. This change requires the latest NDK which contains the change to set the autoneg on the xe0 and xe1 port on the Greyhound.
Signed-off-by: mlok <marty.lok@nokia.com>
Why I did it
To bring in the following fixes:
Revert temporary fix added to disable SA equal DA drops
CS00012273013 - [7.1][J2, J2c+] Disable SA Equals DA trap on DNX
CS00012274222 - How to block the voq for given destination port for a flow from a remote mod-id
CS00012275381 - SAI_INGRESS_PRIORITY_GROUP_STAT_PACKETS is incremented for port's PG's even if there are no traffic sent to that PG
CS00012274433 - Local Fault and Remote Fault are not polled by linkscan thread
How I did it
Merged above fixes to SAI code
How to verify it
Validated by running the basic sanity tests on XGS and DNX chassis platforms including
fib/test_fib.py
decap/test_decap.py
drop_counters/test_drop_counters.py
arp/test_arpall.py
Added midplane_subnet in chassisdb.conf for interfaces-config.sh to create midplane interface in multi-asic namespaces.
Signed-off-by: Sakthivadivu Saravanaraj <sakthivadivu.saravanaraj@nokia.com>
Why I did it
Updated the BCM config recommended by Broadcom for Nokia-IXR7250E-36x400G
How I did it
Updated the BCM config file
How to verify it
Verified running the image with this BCM config in Nokia-IXR7250E-36x400G and ensured that the syncd container was stable, ports were up and passing the traffic.
Signed-off-by: Sakthivadivu Saravanaraj <sakthivadivu.saravanaraj@nokia.com>
-- Based on the new BCM configuration, Modify the portcoreid for the front panel port in the port_config.ini for line card Nokia-IXR7250e-36x400G
-- Correct the pcie.pmal file
-- Update the platform_ndk.json with new field "update-asic-pvt"
-- Add chassis-internal-intf to chassisdb.conf
-- update platform_reboot
Signed-off-by: mlok <marty.lok@nokia.com>
#### Why I did it
Add platform_asic file to each platform folder in sonic-device-data package. The file content will be used as the ground truth of mapping from PLATFORM_STRING to switch ASIC family.
One use case of the mapping is to prevent installing a wrong image, which targets for other ASIC platforms. For example, currently we have several ONIE images naming as sonic-*.bin, it's easy to mistakenly install the wrong image. With this mapping built into image, we could fetch the ONIE platform string, and figure out which ASIC it is using, and check we are installing the correct image.
After this PR merged, each platform vendor has to add one mandatory text file `device/PLATFORM_VENDOR/PLATFORM_STRING/platform_asic`, with the content of the platform's switch ASIC family.
I will update https://github.com/Azure/SONiC/wiki/Porting-Guide after this PR is merged.
You can get a list of the ASIC platforms by `ls -b platform | cat`. Currently the options are
```
barefoot
broadcom
cavium
centec
centec-arm64
generic
innovium
marvell
marvell-arm64
marvell-armhf
mellanox
nephos
p4
vs
```
Also support
```
broadcom-dnx
```
#### How I did it
#### How to verify it
Test one image on DUT. And check the folders under `/usr/share/sonic/device`
Why I did it
Support Nokia ixr7250E IMM and Supervisor cards
How I did it
Added modules x86_64-nokia_ixr7250e_sup-r0 and x86_64-nokia_ixr7250e_36x400g-r0 ../device/nokia directory.
Modified the platform/broadcom/one-image.mk to include NOKIA_IXR7250_PLATFORM_MODULE
Modified the platform/broadcom/rule.mk to include the platform-module-nokia.mk