What I did:
Added flag in sonic_version.yml to see if compiled image is secured or non-secured. This is done using build/compile time environmental variable SECURE_UPGRADE_MODE as define in HLD: https://github.com/sonic-net/SONiC/blob/master/doc/secure_boot/hld_secure_boot.md
This flag does not provide the runtime status of whether the image has booted securely or not. It's possible that compile time signed image (secured image) can boot on non secure platform.
Why I did:
Flag can be used for manual check or by the test case.
ADO: 24319390
How I verify:
Manual Verification
---
build_version: 'master-16191.346262-cdc5e72a3'
debian_version: '11.7'
kernel_version: '5.10.0-18-2-amd64'
asic_type: broadcom
asic_subtype: 'broadcom'
commit_id: 'cdc5e72a3'
branch: 'master-16191'
release: 'none'
build_date: Fri Aug 25 03:15:45 UTC 2023
build_number: 346262
built_by: AzDevOps@vmss-soni001UR5
libswsscommon: 1.0.0
sonic_utilities: 1.2
sonic_os_version: 11
secure_boot_image: 'no'
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
Why I did it
For some devices with small memory, after upgrading to the latest image, the available memory is not enough.
Work item tracking
Microsoft ADO (number only):
26324242
How I did it
Disable restapi feature for LeafRouter which with slim image.
How to verify it
verified on 7050qx T1 (slim image), restapi disabled
verified on 7050qx T0 (slim image), restapi enabled
verified on 7260 T1 (normal image), restapi enabled
Signed-off-by: Nazarii Hnydyn nazariig@nvidia.com
This improvement does not bring any warm-reboot degradation, since the database availability (tcp/ip access over the loopback interface) was fixed by these PRs:
Re-add 127.0.0.1/8 when bringing down the interfaces #15080
Fix potentially not having any loopback address on lo interface #16490
Why I did it
Removed dependency on interfaces-config.service to speed up the boot, because interfaces-config.service takes a lot of time on init
Work item tracking
N/A
How I did it
Changed service files for swss/syncd
How to verify it
Boot and check swss/syncd start time comparing to interfaces-config
Backport PR #17458 due to conflict.
Why I did it
Optimize syslog rate limit feature for fast and warm boot
Work item tracking
Microsoft ADO (number only):
How I did it
Optimize redis start time
Don't render rsyslog.conf in container startup script
Disable containercfgd by default. There is a new CLI to enable it (in another PR)
How to verify it
Manual test
Regression test
Why I did it
Need to share docker image for telemetry and gnmi, and only use telemetry container for 202305 branch
Work item tracking
Microsoft ADO (number only):
How I did it
Add a new docker image, base-gnmi, build sonic-gnmi and sonic-telemetry on this docker image.
Enable telemetry container.
How to verify it
Run end to end test for telemetry and gnmi.
Why I did it
Share docker image to support gnmi container and telemetry container
backport #16863
Work item tracking
Microsoft ADO 25423918:
How I did it
Create telemetry image from gnmi docker image.
Enable gnmi container and disable telemetry container by default.
How to verify it
Run end to end test.
Why I did it
Add the create_only_config_db_buffers attribute to the DEVICE_METADATA|localhost. If the "create_only_config_db_buffers" exists and is equal to "true" - the buffers will be created according to the config_db configuration (for example BUFFER_QUEUE|* table), otherwise the maximum available buffers (which are read from SAI) will be created, regardless of the CONFIG_DB buffers configuration.
Work item tracking
Microsoft ADO (number only):
How I did it
Add the create_only_config_db_buffers.json files for Mellanox devices (not MSFT SKU's), and inject the content to the CONFIG_DB during the swss docker container start.
How to verify it
Manual verification:
Install the image with this PR included on the not MSFT SKU switch
Check the show queue counters output and verify that only configured in CONFIG_DB buffers are created
root@sonic:/home/admin# show queue counters
Port TxQ Counter/pkts Counter/bytes Drop/pkts Drop/bytes
--------- ----- -------------- --------------- ----------- ------------
Ethernet0 UC0 0 0 0 N/A
Ethernet0 UC1 0 0 0 N/A
Ethernet0 UC2 0 0 0 N/A
Ethernet0 UC3 0 0 0 N/A
Ethernet0 UC4 0 0 0 N/A
Ethernet0 UC5 0 0 0 N/A
Ethernet0 UC6 0 0 0 N/A
Open the /usr/share/sonic/device/$DEVICE/$SKU/create_only_config_db_buffers.json and change it to:
"create_only_config_db_buffers": "false"
Do config reload
Check the show queue counters output and verify that all available buffers are created
root@sonic:/home/admin# show queue counters
Port TxQ Counter/pkts Counter/bytes Drop/pkts Drop/bytes
--------- ----- -------------- --------------- ----------- ------------
Ethernet0 UC0 0 0 0 N/A
Ethernet0 UC1 0 0 0 N/A
Ethernet0 UC2 0 0 0 N/A
Ethernet0 UC3 0 0 0 N/A
Ethernet0 UC4 0 0 0 N/A
Ethernet0 UC5 0 0 0 N/A
Ethernet0 UC6 0 0 0 N/A
Ethernet0 UC7 60 15346 0 N/A
Ethernet0 MC8 N/A N/A N/A N/A
Ethernet0 MC9 N/A N/A N/A N/A
Ethernet0 MC10 N/A N/A N/A N/A
Ethernet0 MC11 N/A N/A N/A N/A
Ethernet0 MC12 N/A N/A N/A N/A
Ethernet0 MC13 N/A N/A N/A N/A
Ethernet0 MC14 N/A N/A N/A N/A
Ethernet0 MC15 N/A N/A N/A N/A
Why I did it
Running SONiC releases past 202012 has become really challenging on system with small storage devices (4GB).
Some of these devices can also be limited by only having 4GB of RAM which complicates mitigations.
The main contributor to these issues is the SONiC image growth.
Being able to reduce it by some decent amount should allow these systems to run SONiC longer.
It would also reduce some impacts related to space savings mitigations.
Work item tracking
Microsoft ADO (number only):
How I did it
Add a build option to reduce the image size.
The image reduction process is affecting the builds in 2 ways:
change some packages that are installed in the rootfs
apply a rootfs reduction script
The script itself will perform a few steps:
remove file duplication by leveraging hardlinks
under /usr/share/sonic since the symlinks under the device folder are lost during the build.
under /var/lib/docker since the files there will only be mounted ro
remove some extra files (man, docs, licenses, ...)
some image specific space reduction (only for aboot images currently)
The script can later be improved but for now it's reducing the rootfs size by ~30%.
How to verify it
Compare the size of an image with this option enabled and this option enabled.
Expect the fully extracted content to be ~30% less.
Which release branch to backport (provide reason below if selected)
This is a backport of #16729
Description for the changelog
Add build option to reduce final image size
Why I did it
Enabling kdump by default for cisco-8000 by setting crashkernel cmdline arg in device installer.conf.
After bootup, sonic-kdump-config wipes crashkernel arg from /host/grub/grub.cfg, and resets USE_KDUMP in /etc/default/kdump-tools, so kdump will not be enabled on subsequent reboot.
How I did it
Setting kdump enable config as part of init_cfg.json for cisco-8000 platforms.
How to verify it
Install SONiC image with kdump enabled by default (device/hwsku/installer.conf), then reboot.
Kdump config should persist on subsequent reboots and kdump loaded during bootup
Signed-off-by: Aman Singhal <amans@cisco.com>
Openssh in Debian Bullseye has been updated to 1:8.4p1-5+deb11u2 to fix CVE-2023-38408.
Since we're building openssh with some patches, we need to update our version as well.
Signed-off-by: Saikrishna Arcot <sarcot@microsoft.com>
#### Why I did it
To enable qos config for a certain backend deployment mode, for resource-type "Compute-AI".
This deployment has the following requirement:
- Config below enabled if DEVICE_TYPE as one of backend_device_types
- Config below enabled if ResourceType is 'Compute-AI'
- 2 lossless TCs' (2, 3)
- 2 lossy TCs' (0,1)
- DSCP to TC map uses 4 DSCP code points and maps to the TCs' as follows:
"DSCP_TO_TC_MAP": {
"AZURE": {
"48" : "0",
"46" : "1",
"3" : "3",
"4" : "4"
}
}
- WRED profile has green {min/max/mark%} as {2M/10M/5%}
This required template change <as in the PR> in addition to the vendor qos.json.j2 file (not included here).
### How I did it
#### How to verify it
- with the above change and the vendor config change, generated the qos.json file and verified that the objective stated in "Why I did it" was met
- verified no error
### Description for the changelog
Update qos_config.j2 for Comptue-AI deployment on one of backend device type roles
* [Mellanox] Update SDK/FW/SAI to 4.6.1020/2012.1020/SAIBuild2305.25.0.3 (#16096)
SONiC changes:
1. Support Spectrum4 ASIC FW binary building.
2. Support new SDK sx-obj-desc lib building since new SAI need it.
3. Remove SX_SCEW debian package from Mellanox SDK build since we are no longer using it (we use libxml2 instead).
4. Update SAI, SDK, FW to version 4.6.1020/2012.1020/SAIBuild2305.25.0.3
SDK/FW bug fixes
1. In SPC-1 platforms: Fastboot mode is not operational for Split port with Force mode in 50G speed
SFP modules are kept in disabled state after set LPM (low power mode) on/off for at least 3 minutes.
2. When preforming fast boot from an old SDK version (currently installed) to a newer one (target version), and the system was initially loaded with a new SDK version (past version), and the system has not been wiped, under specific conditions, the fast boot would use the past version's data and may fail.
SDK/FW Features
1. On SN2700 all ports can support y cable by credo
SAI bug Fixes
1. When creating an ACL rule with SAI_ACL_ENTRY_ATTR_FIELD_SRC_IP/SAI_ACL_ENTRY_ATTR_FIELD_DST_IP enabled, and then disabling the field by setting enable=false, a match on L3_type=IPv4 will remain programmed for the rule Issue resolved after the fix
2. Allow the max scale of virtual routers to be configure for SPC-1, SPC-2, SPC-3 when fastboot enable
3. Remove default hash key of SRC_MAC, DST_MAC and ETH_TYPE
SAI features
1. Port init profile
- How I did it
Update SDK/FW/SAI make files
- How to verify it
Run full sonic-mgmt regression on Mellanox platform
Signed-off-by: Kebo Liu <kebol@nvidia.com>
Conflicts:
platform/mellanox/mlnx-sai.mk
* Fix issue: unprintable character is rendered when handling comments in j2
Use "{#-" and "-#}" to mark comments in jinja template
Signed-off-by: Stephen Sun <stephens@nvidia.com>
---------
Signed-off-by: Stephen Sun <stephens@nvidia.com>
Co-authored-by: Stephen Sun <stephens@nvidia.com>
Why I did it
Support FIPS DB configuration
Design Doc: sonic-net/SONiC#1372
Work item tracking
Microsoft ADO (number only): 24411148
How I did it
Add the FIPS Yang model to make FIPS configurable in ConfigDB.
How to verify it
See TestPlan: sonic-net/sonic-mgmt#9092
Build the image and run the tests: sonic-net/sonic-mgmt#9091
Cherypick of #15685
MSFT ADO: 24274591
Why I did it
Two changes:
1 Fix a day1 issue, where check to wait until CONFIG_DB_INITIALIZED is incorrect.
There are multiple places where same incorrect logic is used.
Current logic (until [[ $($SONIC_DB_CLI CONFIG_DB GET "CONFIG_DB_INITIALIZED") ]];) will always result in pass, irrespective of the result of GET operation.
root@str2-7060cx-32s-29:~# sonic-db-cli CONFIG_DB GET "CONFIG_DB_INITIALIZED"
1
root@str2-7060cx-32s-29:~# until [[ $(sonic-db-cli CONFIG_DB GET "CONFIG_DB_INITIALIZED") ]]; do echo "entered here"; done
root@str2-7060cx-32s-29:~#
root@str2-7060cx-32s-29:~#
root@str2-7060cx-32s-29:~# sonic-db-cli CONFIG_DB GET "CONFIG_DB_INITIALIZED"
0
root@str2-7060cx-32s-29:~# until [[ $(sonic-db-cli CONFIG_DB GET "CONFIG_DB_INITIALIZED") ]]; do echo "entered here"; done
root@str2-7060cx-32s-29:~#
Fix this logic by checking for value of flag to be "1".
root@str2-7060cx-32s-29:~# until [[ $(sonic-db-cli CONFIG_DB GET "CONFIG_DB_INITIALIZED") -eq 1 ]]; do echo "entered here"; done
entered here
entered here
entered here
This gap in logic was highlighted when another fix was merged: #14933
The issue being fixed here caused warmboot-finalizer to not wait until config-db is initialized.
2 Set and unset CONFIG_DB_INITIALIZED for warm-reboot case
Currently, during warm shutdown CONFIG_DB_INITIALIZED's value is stored in redis db backup. This is restored back when the dump is loaded during warm-recovery.
So the value of CONFIG_DB_INITIALIZED does not depend on config db's state, however it remain what it was before reboot.
Fix this by setting CONFIG_DB_INITIALIZED to 0 as when the DB is loaded, and set it to 1 after db_migrator is done.
Work item tracking
Microsoft ADO (number only):
How I did it
How to verify it
Why I did it
Sharing the storage of syncd with other proprietary application extensions allows them to communicate with syncd in differnt ways.
If one container wants to pass some information to syncd then shared storage can be used. However, today the shared storage isn't cleaned on restarts making it possible for syncd to read out-of-date information generated in the past.
NOTE: No plans to use it for standard SONIC dockers and we are working on removing the SDK dependency from PMON docker
How I did it
Implemented new service to clean the shared storage.
How to verify it
Do reboot/fast-reboot/warm-reboot/config-reload/systemctl restart swss and verify /tmp/ is cleaned after each restart in syncd container.
Signed-off-by: Stepan Blyschak <stepanb@nvidia.com>
Co-authored-by: Stepan Blyshchak <38952541+stepanblyschak@users.noreply.github.com>
There is a redundant line in init_cfg.json.j2. It would cause pmon service always has "delayed=False". However, we know that PMON has a timer now. So, I try to fix it here.
Why I did it
To reduce the container's dependency from host system
Work item tracking
Microsoft ADO (number only):
17713469
How I did it
Move the k8s container startup script to config engine container, other than mount it from host.
How to verify it
Check file path(/usr/share/sonic/scripts/container_startup.py) inside config engine container.
Signed-off-by: Yun Li <yunli1@microsoft.com>
Co-authored-by: Qi Luo <qiluo-msft@users.noreply.github.com>
For T2 systems using packet mode, the backplane interfaces (Ethernet-BP#) and the fabric card ethernet interfaces are not visible as neighbor interfaces.
In packet mode, these interfaces needs qos and buffer config as well.
This fix addresses that issue and adds the backplane interfaces to the PORTS_ACTIVE list
In the PR sonic-net/sonic-utilities#2850 , for support remote access of linecards paramiko package is installed in sonic-utilities. libffi-dev needs to installed to be able to compile for armhf image
Signed-off-by: Arvindsrinivasan Lakshmi Narasimhan <arlakshm@microsoft.com>
Why I did it
Fix the issue where db_migrator is called before DB is loaded w/ config. This leads to db_migrator:
Not finding anything, and resumes to incorrectly migrate every missing config
This is not expected. migration should happen after the old config is loaded and only new schema changes need migration.
Since DB does not have anything when migrator is called, db_migrator fails when some APIs return None.
The reason for incorrect call is that:
database service starts db_migrator as part of startup sequence.
config-setup service loads data from old-config/minigraph. However, since it has Requires=database.service.
Hence, config-setup starts only when database service is started. And database service is started when db_migrator is completed.
Fixed by:
Check if this is first time boot by checking pending_config_migration flag.
If pending_config_migration is enabled, then do not call db_migrator as part of database service startup.
Let database service start which triggers config-setup service to start.
Now call db_migrator after when config-setup service loads old-config/minigraph
* Update PG headroom settings ports based on port speed/cable length
* Updated XOFF settings to use chip level numbers than core
* Updated PG headroom based on uplink/downlink side
* fix for sonic-config-gen tests
* More fixes for unit test cases
* more test fixes
* Merged multiple functions into one
Why I did it
Current regex not able to capture logs, modify regex to capture syslog messages
Work item tracking
Microsoft ADO (number only): 13366345
How I did it
Code change
How to verify it
sonic-mgmt test case
- Why I did it
We suspect the issue #13791 is caused by redis server being temporarily unavailable during system initialization so we do not use -d in sonic-cfggen, for now, to avoid accessing redis server
- How I did it
Provide a string containing required json data when calling sonic-cfggen
- How to verify it
Manually test it
Signed-off-by: Stephen Sun <stephens@nvidia.com>
rasdaemon is a tool to log hardware errors. It takes 100% CPU during
boot for a few seconds. It impacts fast/warm boot by delaying control
plane restoration for 5 sec on some platforms.
Signed-off-by: Stepan Blyschak <stepanb@nvidia.com>
#### Why I did it
Implementing code changes for https://github.com/sonic-net/SONiC/pull/1203
#### How I did it
Removed the timers and delayed target since the delayed services would start based on event driven approach.
Cleared port table during config reload and cold reboot scenario.
Modified yang model, init_cfg.json to change has_timer to delayed
#### How to verify it
Running regression
Why I did it
Fixes#14179
chassis-packet: missing arp entries for static routes causing high orchagent cpu usage
It is observed that some sonic-mgmt test case calls sonic-clear arp, which clears the static arp entries as well. Orchagent or arp_update process does not try to resolve the missing arp entries after clear.
How I did it
arp_update should resolve the missing arp/ndp static route
entries. Added code to check for missing entries and try ping if any
found to resolve it.
How to verify it
After boot or config reload, check ipv4 and ipv4 neigh entries to make sure all static route entries are present
manual validation:
Use sonic-clear arp and sonic-clear ndp to clear all neighbor entries
run arp_update
Check for neigh entries. All entries should be present.
Testing on T0 setup route/for test_static_route.py
The test set the STATIC_ROUTE entry in conifg db without ifname:
sonic-db-cli CONFIG_DB hmset 'STATIC_ROUTE|2.2.2.0/24' nexthop 192.168.0.18,192.168.0.25,192.168.0.23
"STATIC_ROUTE": {
"2.2.2.0/24": {
"nexthop": "192.168.0.18,192.168.0.25,192.168.0.23"
}
},
Validate that the arp_update gets the proper ARP_UPDATE_VARDS using arp_update_vars.j2 template from config db and does not crash:
{ "switch_type": "", "interface": "", "pc_interface" : "PortChannel101 PortChannel102 PortChannel103 PortChannel104 ", "vlan_sub_interface": "", "vlan" : "Vlan1000", "static_route_nexthops": "192.168.0.18 192.168.0.25 192.168.0.23 ", "static_route_ifnames": "" }
validate route/test_static_route.py testcase pass.
Why I did it
Support to add SONiC OS Version in device info.
It will be used to display the version info in the SONiC command "show version". The version is used to do the FIPS certification. We do not do the FIPS certification on a specific release, but on the SONiC OS Version.
SONiC Software Version: SONiC.master-13812.218661-7d94c0c28
SONiC OS Version: 11
Distribution: Debian 11.6
Kernel: 5.10.0-18-2-amd64
How I did it
#### Why I did it
Enhance the error message output mechanism during swss docker creating
#### How I did it
Capture the output to stderr of `sonic-cfggen` and output it using `echo` to make sure the error message will be logged in syslog.
#### How to verify it
Manually test
Why I did it
All these 3 services started after swss service, which used to start after interface-config service. But #13084 remove the time constraints for swss.
After that, these 3 services has the chance of start earlier when the inteface-config service is restarting the networking service, which could cause db connect request to fail.
How I did it
Delay mux/sflow/snmp timer after the interface-config service.
How to verify it
PR test.
Config reload can repro the issue in 1-3 retries. With this change. config reload run 30+ iterations without hitting the issue.
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
arp_update should resolve the missing arp/ndp static route
entries. Added code to check for missing entries and try ping to
resolve the missing entry.
Why I did it
Fixes#14179
chassis-packet: missing arp entries for static routes causing high orchagent cpu usage
It is observed that some sonic-mgmt test case calls sonic-clear arp, which clears the static arp entries as well. Orchagent or arp_update process does not try to resolve the missing arp entries after clear.
How I did it
arp_update should resolve the missing arp/ndp static route
entries. Added code to check for missing entries and try ping if any
found to resolve it.
How to verify it
After boot or config reload, check ipv4 and ipv4 neigh entries to make sure all static route entries are present
manual validation:
Use sonic-clear arp and sonic-clear ndp to clear all neighbor entries
run arp_update
Check for neigh entries. All entries should be present.
Signed-off-by: anamehra <anamehra@cisco.com>
Why I did it
SONiC currently does not identify 'EdgeZoneAggregator' neighbor. As a result, the buffer profile attached to those interfaces uses the default cable length which could cause ingress packet drops due to insufficient headroom. Hence, there is a need to update the buffer templates to identify such neighbors and assign the same cable length as used by the T1.
How I did it
Modified the buffer template to identify EdgeZoneAggregator as a neighbor device type and assign it the same cable length as a T1/leaf router.
How to verify it
Unit tests pass, and manually checked on a 7260 to see the changes take effect.
Signed-off-by: dojha <devojha@microsoft.com>
Why I did it
This PR addresses the issue mentioned above by loading the acl config as a service on a storage backend device
How I did it
The new acl service is a oneshot service which will start after swss and does some retries to ensure that the SWITCH_CAPABILITY info is present before attempting to load the acl rules. The service is also bound to sonic targets which ensures that it gets restarted during minigraph reload and config reload
How to verify it
Build an image with the following changes and did the following tests
Verified that acl is loaded successfully on a storage backend device after a switch boot up
Verified that acl is loaded successfully on a storage backend ToR after minigraph load and config reload
Verified that acl is not loaded if the device is not a storage backend ToR or the device does not have a DATAACL table
Signed-off-by: Neetha John <nejo@microsoft.com>
- Why I did it
Add Secure Boot support to SONiC OS.
Secure Boot (SB) is a verification mechanism for ensuring that code launched by a computer's UEFI firmware is trusted. It is designed to protect a system against malicious code being loaded and executed early in the boot process before the operating system has been loaded.
- How I did it
Added a signing process to sign the following components:
shim, grub, Linux kernel, and kernel modules when doing the build, and when feature is enabled in build time according to the HLD explanations (the feature is disabled by default).
- How to verify it
There are self-verifications of each boot component when building the image, in addition, there is an existing end-to-end test in sonic-mgmt repo that checks that the boot succeeds when loading a secure system (details below).
How to build a sonic image with secure boot feature: (more description in HLD)
Required to use the following build flags from rules/config:
SECURE_UPGRADE_MODE="dev"
SECURE_UPGRADE_DEV_SIGNING_KEY="/path/to/private/key.pem"
SECURE_UPGRADE_DEV_SIGNING_CERT="/path/to/cert/key.pem"
After setting those flags should build the sonic-buildimage.
Before installing the image, should prepared the setup (switch device) with the follow:
check that the device support UEFI
stored pub keys in UEFI DB
enabled Secure Boot flag in UEFI
How to run a test that verify the Secure Boot flow:
The existing test "test_upgrade_path" under "sonic-mgmt/tests/upgrade_path/test_upgrade_path", is enough to validate proper boot
You need to specify the following arguments:
Base_image_list your_secure_image
Taget_image_list your_second_secure_image
Upgrade_type cold
And run the test, basically the test will install the base image given in the parameter and then upgrade to target image by doing cold reboot and validates all the services are up and working correctly
Fixes#13568
Upgrade from old image always requires squashfs mount to get the next image FW binary. This can be avoided if we put FW binary under platform directory which is easily accessible after installation:
admin@r-spider-05:~$ ls /host/image-fw-new-loc.0-dirty-20230208.193534/platform/fw-SPC.mfa
/host/image-fw-new-loc.0-dirty-20230208.193534/platform/fw-SPC.mfa
admin@r-spider-05:~$ ls -al /tmp/image-fw-new-loc.0-dirty-20230208.193534-fs/etc/mlnx/fw-SPC.mfa
lrwxrwxrwx 1 root root 66 Feb 8 17:57 /tmp/image-fw-new-loc.0-dirty-20230208.193534-fs/etc/mlnx/fw-SPC.mfa -> /host/image-fw-new-loc.0-dirty-20230208.193534/platform/fw-SPC.mfa
- Why I did it
202211 and above uses different squashfs compression type that 201911 kernel can not handle. Therefore, we avoid mounting squashfs altogether with this change.
- How I did it
Place FW binary under /host/image-/platform/mlnx/, soft links in /etc/mlnx are created to avoid breaking existing scripts/automation.
/etc/mlnx/fw-SPCX.mfa is a soft link always pointing to the FW that should be used in current image
mlnx-fw-upgrade.sh is updated to prefer /host/image-/platform/mlnx location and fallback to /etc/mlnx in squashfs in case new location does not exist. This is necessary to do image downgrade.
- How to verify it
Upgrade from 201911 to master
master to 201911 downgrade
master -> master reboot
ONIE -> master boot (First FW burn)
Which release branch to backport (provide reason below if selected)