The following packages have unmet dependencies:
libssl-dev : Depends: libssl1.1 (= 1.1.1n-0+deb11u3) but 1.1.1n-0+deb11u2 is to be installed
E: Unable to correct problems, you have held broken packages.
- Why I did it
To include latest fixes:
1. Warmboot | When trying to reconfigure the Flex Parser header and Flex transition parameters after ISSU, the switch will returned an error even if the configuration was identical to that done before performing the ISSU.
2. Link Up | When toggling many ports of the Spectrum devices while raising 10GbE link up and link maintenance is enabled, the switch may get stuck and may need to be rebooted.
3. Shared buffer | While moving from lossless to lossy while shared headroom was used, reduction of the shared headroom can only be done prior to pool type change and when shared headroom is not utilized.
- How I did it
Updated SDK submodule along with the relevant Makefiles
- How to verify it
Build an image and run tests from "sonic-mgmt".
Signed-off-by: Volodymyr Samotiy <volodymyrs@nvidia.com>
swss:
* 6bafea4 2022-06-29 | [vnetorch] [vxlanorch] fix a set of memory usage issues (#2352) (HEAD -> 202205, github/202205) [Yakiv Huryk]
utilities:
* c64454c 2022-06-28 | [GCU] Moving UniqueLanes from only validating moves, to be a supplemental YANG validator (#2234) (HEAD -> 202205, github/202205) [Mohamed Ghoneim]
* fbd79d4 2022-06-29 | Add check to not allow deleting PO if its member of vlan (#2237) [anilkpan]
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
- Why I did it
New security feature for enforcing strong passwords when login or changing passwords of existing users into the switch.
- How I did it
By using mainly Linux package named pam-cracklib that support the enforcement of user passwords, the daemon named hostcfgd, will support add/modify password policies that enforce and strengthen the user passwords.
- How to verify it
Manually Verification-
1. Enable the feature, using the new sonic-cli command passw-hardening or manually add the password hardening table like shown in HLD by using redis-cli command
2. Change password policies manually like in step 1.
Notes:
password hardening CLI can be found in sonic-utilities repo-
P.R: Add support for Password Hardening sonic-utilities#2121
code config path: config/plugins/sonic-passwh_yang.py
code show path: show/plugins/sonic-passwh_yang.py
3. Create a new user (using adduser command) or modify an existing password by using passwd command in the terminal. And it will now request a strong password instead of default linux policies.
Automatic Verification - Unitest:
This PR contained unitest that cover:
1. test default init values of the feature in PAM files
2. test all the types of classes policies supported by the feature in PAM files
3. test aging policy configuration in PAM files
Avoid write_standby in warm restart context.
sign-off: Jing Zhang zhangjing@microsoft.com
Why I did it
In warm restart context, we should avoid mux state change.
How I did it
Check warm restart flag before applying changes to app db.
How to verify it
Ran write_standby in table missing, key missing, field missing scenarios.
Did a warm restart, app db changes were skipped. Saw this in syslog:
WARNING write_standby: Taking no action due to ongoing warmrestart.
Signed-off-by: bingwang <wang.bing@microsoft.com>
Why I did it
This PR brings two changes
Add lossy PG profile for PG2 and PG6 on T1 for ports between T1 and T2.
After PR Update qos config to clear queues for bounced back traffic #10176 , the DSCP_TO_TC_MAP and TC_TO_PG_MAP is updated when remapping is enable
DSCP_TO_TC_MAP
Before After Why do this change
"2" : "1" "2" : "2" Only change for leaf router to map DSCP 2 to TC 2 as TC 2 will be used for lossless TC
"6" : "1" "6" : "6" Only change for leaf router to map DSCP 6 to TC 6 as TC 6 will be used for lossless TC
TC_TO_PRIORITY_GROUP_MAP
Before After Why do this change
"2" : "0" "2" : "2" Only change for leaf router to map TC 2 to PG 2 as PG 2 will be used for lossless PG
"6" : "0" "6" : "6" Only change for leaf router to map TC 6 to PG 6 as PG 6 will be used for lossless PG
So, we have two new lossy PGs (2 and 6) for the T2 facing ports on T1, and two new lossless PGs (2 and 6) for the T0 facing port on T1.
However, there is no lossy PG profile for the T2 facing ports on T1. The lossless PGs for ports between T1 and T0 have been handled by buffermgrd .Therefore, We need to add lossy PG profiles for T2 facing ports on T1.
We don't have this issue on T0 because PG 2 and PG 6 are lossless PGs, and there is no lossy traffic mapped to PG 2 and PG 6
Map port level TC7 to PG0
Before the PCBB change, DSCP48 -> TC 6 -> PG 0.
After the PCBB change, DSCP48 -> TC 7 -> PG 7
Actually, we can map TC7 to PG0 to save a lossy PG.
How I did it
Update the qos and buffer template.
How to verify it
Verified by UT.
- Why I did it
While doing config reload, FEATURE table may be removed and re-add. During this process, updating FEATURE table is not atomic. It could be that the FEATURE table has entry, but each entry has no field. This PR introduces a retry mechanism to avoid this.
- How I did it
Introduces a retry mechanism to avoid this.
- How to verify it
New unit test added to verify the flow as well as running some manual test.
- Why I did it
To provide an ability to suppress ASAN false positives and have a clean ASAN report for docker-sonic-vs/mlnx-syncd/orchagent docker
- How I did it
Added the "print_suppressions=0" to ASAN configs.
- How to verify it
add a suppression to some ASAN-enabled component (the suppression should catch some leak)
build with ENABLE_ASAN=y
run a test and see that the ASAN report is empty instead of having the suppression summary
Signed-off-by: Yakiv Huryk <yhuryk@nvidia.com>
Why I did it
Support to use symbol links in platform folder to reduce the image size.
The current solution is to copy each lazy installation targets (xxx.deb files) to each of the folders in the platform folder. The size will keep growing when more and more packages added in the platform folder. For cisco-8000 as an example, the size will be up to 2G, while most of them are duplicate packages in the platform folder.
How I did it
Create a new folder in platform/common, all the deb packages are copied to the folder, any other folders where use the packages are the symbol links to the common folder.
Why platform.tar?
We have implemented a patch for it, see #10775, but the problem is the the onie use really old unzip version, cannot support the symbol links.
The current solution is similar to the PR 10775, but make the platform folder into a tar package, which can be supported by onie. During the installation, the package.tar will be extracted to the original folder and removed.
#### Why I did it
Support the following tables which were introduced during dynamic buffer calculation
- LOSSLESS_TRAFFIC_PATTERN
- DEFAULT_LOSSLESS_BUFFER_PARAMETER
#### How I did it
- LOSSLESS_TRAFFIC_PATTERN
|name|type|range|mandatory|description|
|---|---|---|---|---|
|mtu|uint16|64~10240|true|The maximum packet size of a lossless packet|
|small_packet_percentage|uint8|0~100|true|The percentage of small packet|
- DEFAULT_LOSSLESS_BUFFER_PARAMETER
|name|type|range|mandatory|description|
|---|---|---|---|---|
|default_dynamic_th|int8|-8~7|true|The default dynamic_th for all buffer profiles that are dynamically generated for lossless PG|
|over_subscribe_ratio|uint16|-|false|The oversubscribe ratio for shared headroom pool.|
|||||Semantically, the upper bound is the number of physical ports but it can not be represented in the yang module. So we keep the upper bound open. As the type is (signed) integer whose lower bound is 0 by nature, we do not need to specify the range.|
#### How to verify it
Run unit test
To ensure that ASAN logs are always generated. Currently, the way to get the logs is to map the "/var/log/asan" outside of a container, which doesn't work for DVS test run with "--imgname" option.
Signed-off-by: Yakiv Huryk <yhuryk@nvidia.com>
Why I did it
To address internal build failures where the cable len for some of the skus is set to 300m for all tiers.
How I did it
For the buffers test, generate a new output file based off the original expected output with CABLE_LENGTH table updated to use 300m. In the comparison logic, compare against each of the expected output files and if any matches, the testcase is set to pass
Signed-off-by: Neetha John <nejo@microsoft.com>
Why I did it
As part of PCBB changes, we need to enable 2 extra lossless queues. The changes in this PR are done to adjust only the reserved sizes on Th2 for the additional 2 lossless queues
Calculations are done based on 40 downlinks for T1 and 16 uplinks for dual ToR
How to verify it
Verified that the rendering works fine on Th2 dut
Unit tests have been updated to reflect the modified buffer sizes when pcbb is enabled. There are existing testcases that will test the original buffer sizes when pcbb is disabled. With these changes, was able to build sonic-config-engine wheel successfully
Signed-off-by: Neetha John <nejo@microsoft.com>
#### Why I did it
There might be a case where service checker periodic operation determined that specific container is running but when it tries to perform an operation on it, it was already closed by the user. This is a valid flow and we should not log an error message, informative warning is enough.
#### How I did it
I reduce log severity.
#### How to verify it
I verified it manually.
Why I did it
The t0-sonic pool has been fixed, so add it back to azp checker.
How I did it
Remove continueOnError in run-test-template.yml.
Signed-off-by: Ze Gan <ganze718@gmail.com>
#### Why I did it
SSHD keepalive timeout feature not enabled on sonic.
#### How I did it
Enable SSHD keepalive timeout feature by set ClientAliveCountMax to 1.
#### How to verify it
Pass All E2E test case.
Manually test with following steps:
1. Change config and restart sshd
2. Connect a ssh with -vvv option to show debug message
3. Get running ssh by command and stop it:
```
azureuser@liuh-dev-vm-02:~$ ps -auxww | grep vvv
azureus+ 1614153 0.0 0.0 12244 6004 pts/1S+ 15:48 0:00 ssh admin@10.250.0.101 -vvv
azureus+ 1615570 0.0 0.0 8168 2424 pts/3S+ 15:49 0:00 grep --color=auto vvv
azureuser@liuh-dev-vm-02:~$ kill -Stop 1614153
```
4. Check TCP status from server side with ss command:
https://man7.org/linux/man-pages/man8/ss.8.html
```
admin@vlab-01:~$ ss | grep -i ssh
tcp ESTAB 0 010.250.0.101:ssh 10.250.0.1:58150
tcp FIN-WAIT-2 0 010.250.0.101:ssh 10.250.0.1:58164
tcp ESTAB 0 010.250.0.101:ssh 10.250.0.1:57978
```
FIN-WAIT-2 means server already terminate the connection and wait for client response:
https://kb.iu.edu/d/ajmi
. FIN-WAIT-2 <-- <SEQ=300><ACK=101><CTL=ACK> <-- CLOSE-WAIT
5. Check again later will show the session been complete closed:
```
admin@vlab-01:~$ ss | grep -i ssh
tcp ESTAB 0 010.250.0.101:ssh 10.250.0.1:58150
tcp ESTAB 0 010.250.0.101:ssh 10.250.0.1:57978
```
- Why I did it
When LLDP is disabled through feature command, it gets spawned after reboot.
- How I did it
In syncd.sh check if the service is enabled before spawning automatically during cold reboot.
- How to verify it
Disable lldp feature. Perform cold reboot and verify its not spawned.
- Why I did it
Need to execute mlxreg inside pmon docker
- How I did it
Add MFT package to pmon Makefile
- How to verify it
Install image, go to pmon : docker exec -it pmon bash, exec mlxreg
Verifiy warm, fast and cold reboot while MFT is being called in pmon constantly
Signed-off-by: Andriy Yurkiv <ayurkiv@nvidia.com>
Signed-off-by: bingwang <bingwang@microsoft.com>
Why I did it
This PR is to add two extra lossless queues for bounced back traffic.
HLD sonic-net/SONiC#950
SKUs include
Arista-7050CX3-32S-C32
Arista-7050CX3-32S-D48C8
Arista-7260CX3-D108C8
Arista-7260CX3-C64
Arista-7260CX3-Q64
How I did it
Update the buffers.json.j2 template and buffers_config.j2 template to generate new BUFFER_QUEUE table.
For T1 devices, queue 2 and queue 6 are set as lossless queues on T0 facing ports.
For T0 devices, queue 2 and queue 6 are set as lossless queues on T1 facing ports.
Queue 7 is added as a new lossy queue as DSCP 48 is mapped to TC 7, and then mapped into Queue 7
How to verify it
Verified by UT
Verified by coping the new template and generate buffer config with sonic-cfggen
* [ci] Support to skip vstest using include/exclude config file. (#11086)
example:
├── folderA
│ ├── fileA (skip vstest)
│ ├── fileB
│ └── fileC
If we want to skip vstest when changing /folderA/fileA, and not skip vstest when changing fileB or fileC.
vstest-include:
^folderA/fileA
vstest-exclude:
^folderA
* [build] Add version files to docker image dependencies
Signed-off-by: Yong Zhao yozhao@microsoft.com
Why I did it
This PR aims to fix an issue (#10088) by enhancing the script memory_checker.
Specifically, if container is not created successfully during device is booted/rebooted, then memory_checker do not need check its memory usage.
How I did it
In the script memory_checker, a function is added to get names of running containers. If the specified container name is not in current running container list, then this script will exit without checking its memory usage.
How to verify it
I tested on a lab device by following the steps:
Stops telemetry container with command sudo systemctl stop telemetry.service
Removes telemetry container with command docker rm telemetry
Checks whether the script memory_checker ran by Monit will generate the syslog message saying it will exit without checking memory usage of telemetry.
Why I did it
The docker storage driver vfs is not a good option for build, it uses the “deep copy” when building a new layer, leads to lower performance and more space used on disk than other storage drivers.
A better docker storage driver is the default one overlay2, it is a modern union filesystem.
- Why I did it
Recent change to delay PMON service in case of fast/warm reboot introduce an issue when restarting only SWSS service after fast/warm reboot for Nvidia platform.
Since the timer is triggered only when the system boot, in a scenario when the system is after a fast/warm reboot and the user restart SWSS service, as part of syncd.sh script, PMON service will stop but the timer will not start again.
- How I did it
On syncd.sh script, in case of fast/warm indication, check if pmon.timer is running.
If it is running it means we are at the first boot and continue normally.
If it is not running, meaning the service was restarted, start the timer to keep the system behavior consistent.
- How to verify it
Run fast/warm reboot.
service swss restart.
Observe PMON service starting.
Signed-off-by: Shlomi Bitton <shlomibi@nvidia.com>
Why I did it
Recently the nightly testing pipeline found that the autorestart test case was failed when it was run against master image. The reason is Restart= field in each container's systemd configuration file was set to Restart=no even the value of auto_restart field in FEATURE table of CONFIG_DB is enabled.
This issue introduced by #10168 can be reproduced by the following steps:
Issues the config command to disable the auto-restart feature of a container
Runs command config reload or config reload minigraph to enable auto-restart of the container
Checks Restart= field in the container's systemd config file mentioned in step 1 by running the command
sudo systemctl cat <container_name>.service
Initially this PR (#10168) wants to revert the changes proposed by this: #8861. However, it did not fully revert all the changes.
How I did it
When hostcfgd started or was restarted, the Restart= field in each container's systemd configuration file should be initialized according to the value of auto_restart field in FEATURE table of CONFIG_DB.
How to verify it
I verified this change by running auto-restart test case against newly built master image and also ran the unittest: