Found another syncd timing issue related to clock going backwards.
To be safe disable the ntp long jump.
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
- What I did
Add configuration to avoid ntpd from panic and exit if the drift between new time and current system time is large.
- How I did it
Added "tinker panic 0" in ntp.conf file.
- How to verify it
[this assumes that there is a valid NTP server IP in config_db/ntp.conf]
Change the current system time to a bad time with a large drift from time in ntp server; drift should be greater than 1000s.
Reboot the device.
Before the fix:
3. upon reboot, ntp-config service comes up fine, ntp service goes to active(exited) state without any error message. This is because the offset between new time (from ntp server) and the current system time is very large, ntpd goes to panic mode and exits. The system continues to show the bad time.
After the fix:
3. Upon reboot, ntp-config comes up fine, ntp services comes up from and stays in active (running) state. The system clock gets synced with the ntp server time.
- Move all minigraph-related action from rc.local to updategraph
- updategraph service is now after database. All feature services are now after and depending on updategraph
Modify minigraph parser output format so it fit DB schema
Modify configuration templates to fit new schema
Systemd services dependencies are modified so database starts before any configuration consumer
* Single image
* Fix review comments
* Update syncd service. Add HW mgmt to Mellanox single image.
* Add single image template for Broadcom platform.
SKU should be provided during configure:
make configure PLATFORM=broadcom SKU=Force10-S6000
* Add single image template for Cavium platform.
SKU should be provided during configure:
make configure PLATFORM=cavium SKU=AS7512
* Add description to sonic_debian_extension.j2 file.