port_config.ini for HWSKU Arista-7050CX3-32S-C32 has missing speed column and duplicated lanes.
The incorrect speed causes issues in Orchagent RESTARTCHECK as the below task remains as the remaining item during swss shutdown.
Update minigraph parser to retrieve kubernetes server info from minigraph.xml and update "KUBERNETES_MASTER|SERVER" in running config.
Update minigraph parser to include clusterName from minigraph.xml into "DEVICE_METADATA|localhost"
snmpd's compile is always failed with file truncated on ARM64 arch, the error log is like "/usr/bin/ld: mibgroup/ip-forward-mib/inetCidrRouteTable/.libs/inetCidrRouteTable_interface.o: file not recognized: file truncated"
Co-authored-by: Xianghong Gu <xgu@centecnetworks.com>
- Why I did it
Fix issue: ptf_nn_agent isn't able to start in syncd-rpc docker on buster.
- How I did it
The issue is fixed by installing python-dev, cffi and nnpy for python 2 explicitly.
- How to verify it
Run copp test on RPC image.
**- Why I did it**
In thermalctd, when speed of fan exceeds threshold, the fan status will be saved as "bad". So in system health, it is better to check fan speed before fan status. In this case, if fan speed exceeds threshold, we get more detailed information.
**- How I did it**
Move fan speed check logic before fan status check
**- How to verify it**
Manual test
Starting with BRCM SAI 4.3.1.5 we see the following :ethtool not fount" error in syslog during boot up:
```
Jan 27 07:36:14.712472 str-s6100-acs-1 INFO syncd#/supervisord: syncd sh: 1:
Jan 27 07:36:14.712844 str-s6100-acs-1 INFO syncd#/supervisord: syncd ethtool: not found
Jan 27 07:36:14.713228 str-s6100-acs-1 INFO syncd#/supervisord: syncd #015
Jan 27 07:36:14.713840 str-s6100-acs-1 INFO syncd#syncd: [0] SAI_API_HOSTIF:_brcm_sai_hostif_speed_set:11894 cmd ethtool -s Ethernet39 speed 40000 rc:32512
Jan 27 07:36:14.717204 str-s6100-acs-1 NOTICE swss#orchagent: :- setHostIntfsOperStatus: Set operation status DOWN to host interface Ethernet39
Jan 27 07:36:14.717204 str-s6100-acs-1 NOTICE swss#orchagent: :- initPort: Initialized port Ethernet39
Jan 27 07:36:14.717204 str-s6100-acs-1 NOTICE swss#orchagent: :- initializePort: Initializing port alias:Ethernet36 pid:1000000000040
Jan 27 07:36:14.726793 str-s6100-acs-1 NOTICE swss#portsyncd: :- onMsg: nlmsg type:16 key:Ethernet36 admin:0 oper:0 addr:4c:76:25:f5:48:80 ifindex:75 master:0
Jan 27 07:36:14.727967 str-s6100-acs-1 NOTICE swss#portsyncd: :- onMsg: Publish Ethernet36(ok) to state db
Jan 27 07:36:14.729331 str-s6100-acs-1 NOTICE swss#orchagent: :- addHostIntfs: Create host interface for port Ethernet36
Jan 27 07:36:14.752398 str-s6100-acs-1 INFO syncd#/supervisord: syncd sh: 1: ethtool: not found#015
Jan 27 07:36:14.752689 str-s6100-acs-1 INFO syncd#syncd: [0] SAI_API_HOSTIF:_brcm_sai_hostif_speed_set:11894 cmd ethtool -s Ethernet36 speed 40000 rc:32512
Jan 27 07:36:14.756050 str-s6100-acs-1 NOTICE swss#orchagent: :- setHostIntfsOperStatus: Set operation status DOWN to host interface Ethernet36
Jan 27 07:36:14.757585 str-s6100-acs-1 NOTICE swss#orchagent: :- initPort: Initialized port Ethernet36
```
It seems that starting with BRCM SAI 4.2.1.5 syncd is using ethtool to set the host interface speed and since this ethtool was not part of the syncd Docker, we observe these "ethtool not found" issue.
This update includes the following changes
> [syncd armhf] Fix syncd crash when running community test suites (#777)
> Revert "[tests]:Add unittest for MACsec on p2p establishment (#771)"
> [tests]:Add unittest for MACsec on p2p establishment (#771)
> [tests] Enable azure pipeline make check to respect unittests (#760)
**- Why I did it**
As per https://pypi.org/project/pip/ pip 21.0 does not not support Python 2 from Jan 2021. Most places in the codebase have already been pinned, but this one was missed.
**- How I did it**
Pin pip2 < version 21 in build_debian.sh
fixesAzure/sonic-utilities#1389
With the recent changes in sudoer files. The show commands fails for the read-only users.
The problem here is the 'docker ps' is failing in the function [get_routing_stack()](8a1109ed30/show/main.py (L54)) therefore all the CLI commands are failing.
Signed-off-by: Arvindsrinivasan Lakshmi Narasimhan <arlakshm@microsoft.com>
Signed-off-by: Arvindsrinivasan Lakshmi Narasimhan <arlakshm@microsoft.com>
- Why I did it
The command sudo ip netns identify <pid> is used in function get_current_namespace
to check in the cli command is running in host context or within a namespace.
This function is used for every CLI command and command sudo ip netns identify <pid> needs to be added in sudoer files to allow users with RO access to run show cli commands
This problem is not there on single asic platforms.
- How I did it
Add ip netns identify [0-9]* to sudoers file.
**- Why I did it**
sonic-utilities will become dependent upon sonic-platform-common as of https://github.com/Azure/sonic-utilities/pull/1386.
**- How I did it**
- Add sonic-platform-common as a dependency in docker-sonic-vs.mk
- Additionally, no longer install Python 2 packages of swsssdk and sonic-py-common, as they should no longer be needed.
* c2fb282 2021-01-29 | [ecnconfig] Allow ecn unit test to run without sudo (#1390) [Neetha John]
* 6cc635b 2021-01-29 | [sonic-installer] Add information to syslog (#1369) [Dmytro]
* 7a8024a 2021-01-27 | Prevent user from adding more then a single untagged VLAN to an interface (#1382) [Eran Dahan]
* 41e62c6 2021-01-26 | [pcieutil] Add 'pcie-aer' sub-command to display AER stats (#1169) [Arun Saravanan Balachandran]
* 47f412b 2021-01-26 | Improve robustness of consutil plugin loading (#1353) [Samuel Angebault]
* 64aa1b8 2021-01-25 | [show] Fix warnings, related to gearbox, while show commands execution (#1343) [maksymbelei95]
* ff226d0 2021-01-25 | Prevent configuring IP interface on a port which is a member of VLAN (#1374) [Eran Dahan]
* f1522b9 2021-01-21 | [config_mgmt.py]: Set leaf-list to empty list while port breakout. (#1268) [Praveen Chaudhary]
* 99c05d5 2021-01-21 | add vlan_intf_object only if there are ipv4 or ipv6 mappings (#1377) [Sumukha Tumkur Vani]
* b082684 2021-01-21 | [ecn] Add tests for ecnconfig command (#1372) [Neetha John]
* 23e0920 2021-01-21 | [sfpshow] Enhance QSFP-DD DOM information (#1207) [shlomibitton]
* f4edba1 2021-01-20 | [ecnconfig] handle backend port names when extracting port I/F ID from the port name (#1361) [Mahesh Maddikayala]
Signed-off-by: Danny Allen <daall@microsoft.com>
Some commands used during build will prompt user interactively, but this is not expected during build. Since most output is collected into log file, user could not see the prompt and feel the build process hangs.
- How I did it
Use mv command in non interactive mode
Redirect stdin to null if command output is collected into log file.
- Why I did it
Initially, we used Monit to monitor critical processes in each container. If one of critical processes was not running
or crashed due to some reasons, then Monit will write an alerting message into syslog periodically. If we add a new process
in a container, the corresponding Monti configuration file will also need to update. It is a little hard for maintenance.
Currently we employed event listener of Supervisod to do this monitoring. Since processes in each container are managed by
Supervisord, we can only focus on the logic of monitoring.
- How I did it
We borrowed the event listener of Supervisord to monitor critical processes in containers. The event listener will take
following steps if it was notified one of critical processes exited unexpectedly:
The event listener will first check whether the auto-restart mechanism was enabled for this container or not. If auto-restart mechanism was enabled, event listener will kill the Supervisord process, which should cause the container to exit and subsequently get restarted.
If auto-restart mechanism was not enabled for this contianer, the event listener will enter a loop which will first sleep 1 minute and then check whether the process is running. If yes, the event listener exits. If no, an alerting message will be written into syslog.
- How to verify it
First, we need checked whether the auto-restart mechanism of a container was enabled or not by running the command show feature status. If enabled, one critical process should be selected and killed manually, then we need check whether the container will be restarted or not.
Second, we can disable the auto-restart mechanism if it was enabled at step 1 by running the commnad sudo config feature autorestart <container_name> disabled. Then one critical process should be selected and killed. After that, we will see the alerting message which will appear in the syslog every 1 minute.
- Which release branch to backport (provide reason below if selected)
201811
201911
[x ] 202006
The requirement for zebra to be ready to accept connections is a generic problem that is not
specific to bgpd. Making the script to wait for zebra socket a separate script and let bgpd and
staticd to wait for zebra socket.
Changes in the new release:
1. Policy based hashing optimization
2. New attribute support for Max port headroom
3. Tunnel ECN map fixes
4. Tunnel EVPN skeleton extensions (peer attrib, maps)
5. Bridge port admin not affecting port admin (optimize port down time)
6. CRM new API for neighbors and tunnel termination entries
7. Improve FDB event for flush by bridge port (before, null bridge was reported to SONiC, now the bridge will be extracted from bridge port)
8. DHCP L2 v4+v6 traps (for ZTP use case)
9. Generic counter implementation
Signed-off-by: Kebo Liu <kebol@nvidia.com>
This commit fixes a typo in the fix delivered in PR #6538
syncd fails on the armhf platform within sonic-config-engine/portconfig.py when importing the following
'from swsscommon.swsscommon import ConfigDBConnector'
- combine docker-ptf-saithrift into docker-ptf docker
- build docker-ptf under platform vs
- remove docker-ptf for other platforms
Signed-off-by: Guohan Lu <lguohan@gmail.com>
During ISSU, "mlxsw_minimal" driver still trying to access firmware, in some cases FW could return some wrong critical threshold value which will cause switch shutdown.
**- How I did it**
In order to prevent "mlxsw_minimal" driver from accessing ASIC during ISSU, SDK will raise "OFFLINE" 'udev' event
at the early beginning of such flow. When this event is received, hw-management will remove "mlxsw_minimal" driver.
There is no need to implement the opposite "ONLINE" event since this flow is ended up with "kexec".
**- How to verify it**
repeatedly perform warm reboot, make sure there is no switch shutdown occurred.
* Fix exception in bgpmon caused by duplicate keys
It is possible that BGP neighbors in IPv4 and IPv6 address families
share the same name (such as bgp monitor). However, such case is not
handled in bgpmon, and an Exception will be raised. This commit will
address the issue by Using set instead of list to avoid duplicate keys.
Bugs fixes:
All | Kernel | During system reload when CPU is loaded with heavy traffic, a Kernel Panic may occur.
All | Modules, Port split | FW stuck when device rebooted with locked Optical Transceivers in split mode
Spectrum-3 | PFC | On Spectrum-3 systems, slow reaction time to Rx pause packets on 40GbE ports may lead to buffer overflow on servers.
Spectrum-3 | SN4700, Port Split | On rare occasion SN4700, conducting 100G split (4x25G) in NRZ when splitter port 1 or 2 are down, ports 3 and 4 will also go down.
Enahncments:
All | Kernel | new notification on ISSU start, so other kernel drivers can disable any interface to ASIC
Signed-off-by: Kebo Liu <kebol@nvidia.com>
Recent changes brought l2 vlan concept which do not have DHCP
clients behind them and so DHCP relay is not required. Also,
dhcpmon fails to launch on those vlans as their interfaces
lack IP addresses. This PR limit launch of both DHCP relay
and dhcpmon to L3 vlans only.
singed-off-by: Tamer Ahmed <tamer.ahmed@microsoft.com>
- Support for non-template based FRR configurations (BGP, route-map, OSPF, static route..etc) using config DB schema.
- Support for save & restore - Jinja template based config-DB data read and apply to FRR during startup
**- How I did it**
- add frrcfgd service
- when frr_mgmg_framework_config is set, frrcfgd starts in bgp container
- when user changed the BGP or other related table entries in config DB, frrcfgd will run corresponding VTYSH commands to program on FRR.
- add jinja template to generate FRR config file to be used by FRR daemons while bgp container restarted
**- How to verify it**
1. Add/delete data on config DB and then run VTYSH "show running-config" command to check if FRR configuration changed.
1. Restart bgp container and check if generated FRR config file is correct and run VTYSH "show running-config" command to check if FRR configuration is consistent with attributes in config DB
Co-authored-by: Zhenhong Zhao <zhenhong.zhao@dell.com>
**- Why I did it**
For now `hwsku.json` and `platform.json` dont support optional fields. For example no way to add `fec` or `autoneg` field using `platform.json` and `hwsku.json`.
**- How I did it**
Added parsing of optional fields from hwsku.json.
**- How to verify it**
Add optional field to `hwsku.json`. After first boot will be generated new `config_db.json` or you can generate it using `sonic-cfggen` command. In this file must be optional field from `hwsku.json` or check using command `redis-cli hgetall PORT_TABLE:Ethernet0`
Example of `hwsku.json`, that must be parsed:
```
{
"interfaces": {
"Ethernet0": {
"default_brkout_mode": "1x100G[40G]",
"fec": "rs",
"autoneg": "0"
},
...
}
```
Example of generated `config_db.json`:
```
"PORT": {
"Ethernet0": {
"alias": "Ethernet0",
"lanes": "0,1,2,3",
"speed": "100000",
"index": "1",
"admin_status": "up",
"fec": "rs",
"autoneg": "0",
"mtu": "9100"
},
```
So, we can see this entries in redis db:
```
admin@sonic:~$ redis-cli hgetall PORT_TABLE:Ethernet0
1) "alias"
2) "Ethernet0"
3) "lanes"
4) "0,1,2,3"
5) "speed"
6) "100000"
7) "index"
8) "1"
9) "admin_status"
10) "up"
11) "fec"
12) "rs"
13) "autoneg"
14) "0"
15) "mtu"
16) "9100"
17) "description"
18) ""
19) "oper_status"
20) "up"
```
Also its way to fix `show interface status`, `FEC` field but also need add `FEC` field to `hwsku.json`.
Before:
```
admin@sonic:~$ show interfaces status
Interface Lanes Speed MTU FEC Alias Vlan Oper Admin Type Asym PFC
----------- --------------- ------- ----- ----- ----------- ------ ------ ------- --------------- ----------
Ethernet0 0,1,2,3 100G 9100 N/A Ethernet0 routed up up QSFP28 or later N/A
```
After:
```
admin@sonic:~$ show interfaces status
Interface Lanes Speed MTU FEC Alias Vlan Oper Admin Type Asym PFC
----------- --------------- ------- ----- ----- ----------- ------ ------ ------- --------------- ----------
Ethernet0 0,1,2,3 100G 9100 rs Ethernet0 routed up up QSFP28 or later N/A
```
**- Why I did it**
Prior to SONiC using Debian Buster, we needed to build Python 3.5 or newer from source for installation in the SNMP container, becuase it wasn't available from the Debian repository for Jessie or Stretch. Now that all containers are based on Buster, we simply install Python 3.7 from the Debian repository in the host as well as all containers. We are no longer building Python 3 from source, so the Makefile is unused and we no longer need to install build dependencies in the slave containers.
**- How I did it**
- Remove Python 3 makefile
- No longer install Python 3 build dependencies in the slave containers.
Submodule changes to be committed:
* src/sonic-platform-daemons 81318f7...e72f6cd (3):
> [ledd] Minor refactor; add unit tests (#143)
> [thermalctld] Report unit test coverage (#141)
> [psud] Increase unit test coverage (#140)
Fixes#6445
Because the ipmihelper.py script in the 9332 folder is slightly different than the common one (due to LGTM fixes), when the common one gets copied during build time it causes the workspace/build to become dirty.
Signed-off-by: Danny Allen <daall@microsoft.com>
**- Why I did it**
Ledd is the last daemon that is not enabled to run in python3.
Even though there is a plan to deprecate this daemon and to replace it by something else it's one simple step toward python2 deprecation.
**- How I did it**
Changed the `command=` line for `ledd` in the `supervisord` configuration of `pmon`.
Copied what was done for other daemons.
**- How to verify it**
Booting a product that has a `led_control.py` should now show the ledd running in python3.
I ran `python3 -m pylint` on all `led_control.py` plugin which means that most of them should be python3 compliant.
There is however still a risk that some might not work.
Meet the requirement for the MUX_CABLE table that IPv6 loopbacks have a /128 prefix
Note that this change only affects the MUX_CABLE table, all other tables continue to use the loopback address provided in minigraph.
Signed-off-by: Lawrence Lee <lawlee@microsoft.com>