Author SHA1 Message Date
Samuel Angebault
8d419ca2c5
[Arista] Remove arista.log from rsyslog default logrotate (#9731)
Why I did it
In parallel of this change Arista added a custom logrotate configuration as part of its driver library.
Having 2 logrotate configuration for the same log file triggers an issue.

Fixes aristanetworks/sonic#38

How I did it
Arista merged a few changes in sonic-buildimage which added a logrotate configuration aristanetworks/sonic@e43c797
It is therefore the right path to remove the arista.log line from the logrotate.d/rsyslog configuration.

How to verify it
Logrotate works without any error message, arista log rotation happens and arista daemons still append logs once file was truncated.
2022-03-11 08:09:07 -08:00
Marty Y. Lok
c40f04f0e2
[chassis][supervisor]monit container-checker failed due to unexpected "database-chassis" docker running #9042 (#9043)
Why I did it
Fixed the monit container_checker fails due to unexpected "database-chassis" docker running on Supervisor card in the VOQ chassis. fixes #9042

How I did it
Added database-chassis to the always running docker list if platform is supervisor card.

How to verify it
Execute the CLI command "sudo monit status container_checker"


Signed-off-by: mlok <marty.lok@nokia.com>
2022-03-03 17:56:08 -08:00
wenyiz2021
2d0b063191
Update container_checker for multi-asic devices when state is 'always_enabled' (#10067)
* Update container_checker for multi-asic devices 

Update container_checker for multi-asic devices to add database containers in always_running_containers. 
Previous change was made for single-asic, and that database containers were not considered as feature when writing to state_db.

* Update container_checker

Update an indent
2022-02-23 18:06:30 -08:00
Stepan Blyshchak
fb752a4ae5
[rsyslog.j2] fix typo in VAR_LOG_SIZE_KB (#9954)
This issue causes negative threshold value and thus deleting log files even when there is enough space.

This issue causes negative threshold value and thus deleting log files even when there is enough space.

- Why I did it
To fix an issue when log files get deleted even if there is enough space.

- How I did it
Fixed an typo.

- How to verify it
Run the portion of the script that calculates threshold, see that the threshold is calculated correctly.

Signed-off-by: Stepan Blyschak <stepanb@nvidia.com>
2022-02-17 10:16:44 +02:00
Prince George
ff14aebef9
Close console session due to user inactivity (#9890)
Signed-off-by: Prince George <prgeor@microsoft.com>
2022-02-02 09:41:21 +05:30
dflynn-Nokia
b6939b9927
[firsttime boot] suppress error message on platforms not supporting kdump (#9521)
Why I did it
Eliminate benign firsttime boot error reported when running on platforms that do not support kdump.

How I did it
Change rc.local to check for presence of the file /etc/default/kdump-tools before referencing it.

How to verify it
Install a new image on an armhf or arm64 platform and check for a failed reference to /etc/default/kdump-tools on firsttime boot.
2022-01-20 18:27:10 -08:00
liuh-80
f166b991a7
[image]: Prevent radius passkey and snmp community string into syslog. (#9727)
[image]: Prevent radius passkey and snmp community string into syslog.  (#9727)

#### Why I did it
    Prevent radius passkey and snmp community string into syslog.

#### How I did it
    Add radius and snmp config command to PASSWD_CMDS

#### How to verify it
    Run and pass all UTs.

#### Which release branch to backport (provide reason below if selected)

<!--
- Note we only backport fixes to a release branch, *not* features!
- Please also provide a reason for the backporting below.
- e.g.
- [x] 202006
-->

- [ ] 201811
- [ ] 201911
- [ ] 202006
- [ ] 202012
- [ ] 202106

#### Description for the changelog
    Add radius and snmp config command to PASSWD_CMDS to prevent radius passkey and snmp community string into syslog.

#### A picture of a cute animal (not mandatory but encouraged)
2022-01-17 16:26:22 +08:00
Sudharsan Dhamal Gopalarathnam
bd0a19aa17
[rsyslog]Setting log file size to 16Mb (#9504)
Why I did it
The existing log file size in sonic is 1 Mb. Over a period of time this leads to huge number of log files which becomes difficult for monitoring applications to handle.
Instead of large number of small files, the size of the log file is not set to 16 Mb which reduces the number of files over a period of time.

How I did it
Changed the size parameter and related macros in logrotate config for rsyslog

How to verify it
Execute logrotate manually and verify the limit when the file gets rotated.

Signed-off-by: Sudharsan Dhamal Gopalarathnam <sudharsand@nvidia.com>
2022-01-14 10:24:07 -08:00
noaOrMlnx
0908f9ec49
[CoPP] Add always_enabled field (#9302)
*Add the "always_enabled" field to copp_cfg.j2 file, in order to allow traps without an entry in features table, to be installed automatically.
2021-11-30 11:04:15 -08:00
Brian O'Connor
002827f08e
[PINS] Add APPL_STATE_DB and response path log (#9082)
- Add APPL_STATE_DB to database_config.json
- Clear APPL_STATE_DB during SwSS container restarts
- Add response path log file to logrotate config: responsepublisher.rec

Co-authored-by: PINS Working Group <sonic-pins-subgroup@googlegroups.com>
2021-11-24 10:31:06 -08:00
Renuka Manavalan
a685fe1765
add arista.log to logrotate (#9245) 2021-11-15 07:29:30 -08:00
Guohan Lu
5f11eb320e Revert "sysready (#8889)"
This reverts commit d7e5372e54.
2021-11-10 15:36:20 -08:00
LuiSzee
5b284767f6 Update Centec platform support for Bullseye and 5.10 kernel (#7)
1. Fix build for armhf and arm64
2. upgrade centec tsingma bsp support to 5.10 kernel
3. modify centec platform driver for linux 5.10

Co-authored-by: Shi Lei <shil@centecnetworks.com>
2021-11-10 15:27:22 -08:00
Saikrishna Arcot
b8a7a6355b Update the base Debian system installation script to get Bullseye
Python 2 is no longer available, so remove those packages, and remove
the pip2 commands. For picocom and systemd, just install from the
regular repo, since there's no backports yet.

Signed-off-by: Saikrishna Arcot <sarcot@microsoft.com>
2021-11-10 15:27:22 -08:00
Senthil Kumar Guruswamy
d7e5372e54
sysready (#8889) 2021-11-10 14:52:52 -08:00
abdosi
ea91a72b79
[multi-asic] fix syslog not getting generated. (#9160)
Fixes #9159
2021-11-03 18:29:09 -07:00
Maxime Lorrillere
81f4fca3dc
Allow database instances on multi-asic linecards to connect to chassis DB (#8583)
Add code to interfaces-config.sh to configure eth1 in multi-asic
containers so that they can access midplane subnet.

Co-authored-by: Maxime Lorrillere <mlorrillere@arista.com>
2021-10-26 18:27:09 -07:00
Ying Xie
638c287837
[copp] bind copp-config.service to sonic.target (#8969)
copp-config service needs to be started after sonic.target so that it could
render the copp-config with the latest information.

It also needs to be restarted when config reload or load_minigraph is invoked.

Signed-off-by: Ying Xie <ying.xie@microsoft.com>
2021-10-13 21:07:44 -07:00
abdosi
13ec43bc68
[baseimage]: Logrotate for wtmp and btmp files. (#8743)
Added logrotate file for wtmp and btmp to override default conf and set size cap as 100K as done in 
PR: #865. For buster this is control by separate file wtmp and btmp.

Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
2021-09-15 23:28:27 -07:00
Sudharsan Dhamal Gopalarathnam
db529af203
Removing execute permission from copp config file (#8680)
*Removed execute permissions from the systemd copp-config.service file. 
Without this we will get a warning: "Configuration file /lib/systemd/system/copp-config.service is marked executable. Please remove executable permission bits. Proceeding anyway."
2021-09-13 09:10:21 -07:00
Ying Xie
41643a9729
[202012][fstrim] delay fstrim timer after sonic.target (#8737)
Why I did it
fstrim has dependency on pmon docker.

How I did it
start fstrim timer after sonic.target.

How to verify it
local test and PR test.

Signed-off-by: Ying Xie ying.xie@microsoft.com
2021-09-13 07:37:46 -07:00
dflynn-Nokia
7bae388e2f
[Nokia ixs7215] Add support for changing the console baud rate (#8595)
This commit adds support for changing the default console baud rate configured
within the U-Boot bootloader. That default baud rate is exposed via the value
of the U-Boot 'baudrate' environment variable. This commit removes logic that
hardcoded the console baud rate to 115200 and instead ensures that the U-Boot
'baudrate' variable is always used when constructing the Linux kernel boot
arguments used when booting Sonic.

A change is also made to rc.local to ensure that the specified baud rate is set
correctly in the serial getty service.
2021-08-26 07:14:34 -07:00
byu343
cdfb4855dc
[macsec] Add eapol to copp config (#8416)
This change enables the control packets of MACsec to be processed by CPU.
2021-08-23 18:56:23 -07:00
Volodymyr Samotiy
e3a30deea9
[monit] Periodically monitor VNET route consistency (#8266)
*To run VNET route consistency check periodically.
*For any failure, the monit will raise alert based on return code.
Signed-off-by: Volodymyr Samotiy <volodymyrs@nvidia.com>
2021-08-19 16:29:25 -07:00
abdosi
2348794ef0
Enable sysctl fib_multipath_use_neigh (#8502)
Enable fib_multipath_use_neigh for v4
https://www.kernel.org/doc/Documentation/networking/ip-sysctl.txt

Why I did:
This is helpful if the neighbor are not directly connected then Kernel forward to unreachable neighbor option. With this option forwarding using neighbor state to be valid.
2021-08-18 15:53:17 -07:00
Saikrishna Arcot
c8b5daed27 Upgrade to ifupdown2 3.0.0 with a patch to fix using broadcast addresses
In version 3.0.0, If a broadcast address is specified in
/etc/network/interfaces, then when ifup is run, it will fail with an
error saying `'str' object has no attribute 'packed'`. This appears to
be because it expects all attributes for an interface to be "packable"
into a compact binary representation. However, it doesn't actually
convert the broadcast address into an IPNetwork object (other addresses
are handled).

Therefore, convert the broadcast address it reads in from a str to an
IPNetwork object.

Also explicitly specify the scope of the loopback address in
/etc/network/interfaces as host scope. Otherwise, it will get added as
global scope by default. As part of this, use JSON to parse ip's output
instead of text, for robustness.

Signed-off-by: Saikrishna Arcot <sarcot@microsoft.com>
2021-08-12 23:18:01 -07:00
Blueve
3da6f12b0b
[port_config] Introduce ad-hoc mport_config.json file (#8066)
Signed-off-by: Jing Kan jika@microsoft.com
2021-07-15 08:56:35 +08:00
Stepan Blyshchak
3a2b8c6ba5
[SONiC Application Extension] support warm/fast reboot for extension packages (#7286)
#### Why I did it

I made this change to support warm/fast reboot for SONiC extension packages as per HLD Azure/SONiC#682.

#### How I did it

I extended manifest.json.j2 with new warm/fast reboot related fields and also extended sonic_debian_extension.j2 script template to generate the shutdown order files for warm and fast reboot.
2021-07-11 06:58:05 -07:00
shlomibitton
776a446d76
[dhcp_relay] Disable dhcp_relay for ToRRouter switches type by the feature manager (#7789)
- Why I did it
Currently dhcp packets are disabled by the COPP manager for non ToRRouter type switches.
Even if the feature is enabled, DHCP packets wont hook to the CPU since the COPP manager will not trap this packets.
This change is to disable dhcp_relay by default for non ToRRouter switches from init_cfg.json.
With this approach, if the user want to enable the feature for non ToRRouter switches, manual enablement is required by the 'feature' configuration.
This is to keep the current approach for MSFT production issue with dhcp relay for non ToRRouter switched and allow the user to decide if to use it or not.

- How I did it
Configure dhcp_relay 'disabled' by default on init_cfg.json for non ToRRouter switches.
Remove the exclusion of dhcp packets on copp_cfg.json

- How to verify it
Enable dhcp_relay feature on a non ToRRouter switch.
Unit-tests modified so the default values on mocked CONFIG DB in 'test_vectors.py' for dhcp_relay will be 'disabled'.
This is by the change for 'init_cfg.json.j2'.
For ToRRouter the state will change from 'disabled' to 'enabled'.
Another test case added for a 'ToR' switch type, this is to test the state is 'enabled' if the user configured it to be so.
2021-07-08 09:10:46 +03:00
rajendra-dendukuri
f4b0c8fe4e
[kdump] Fix kdump error message when a reboot is issued (#7985)
dash doesn't support += operation to append to a variable's value. Use KDUMP_CMDLINE_APPEND="${KDUMP_CMDLINE_APPEND} " instead

The below error message is seen when a reboot is issued.

[ 342.439096] kdump-tools[13655]: /etc/init.d/kdump-tools: 117: /etc/default/kdump-tools: KDUMP_CMDLINE_APPEND+= panic=10 debug hpet=disable pcie_port=compat pci=nommconf sonic_platform=x86_64-accton_as7326_56x-r0: not found
2021-07-01 11:52:38 -07:00
xumia
5c503b81ae
Fix vtysh shell-ingestion security issue (#7759)
Fix vtysh shell-ingestion security issue
Only expose the limited parameters of the command vtysh show.
2021-06-28 09:57:08 +08:00
Sujin Kang
ecc5073731
Support multiple pcie configuration file and change the pcie status table name to match with pcied changes (#7886)
Why I did it
Support multiple pcie configuration file and change the pcie status table name
This is to match with below two PRs.
Azure/sonic-platform-common#195
Azure/sonic-platform-daemons#189

How I did it
Check pcie configuration file with wild card and change the device status table name

How to verify it
Restart with changes and see if the pcie check works as expected.
2021-06-16 16:05:48 -07:00
yozhao101
1a3cab43ac
[Monit] Deprecate the feature of monitoring the critical processes by Monit (#7676)
Signed-off-by: Yong Zhao yozhao@microsoft.com

Why I did it
Currently we leveraged the Supervisor to monitor the running status of critical processes in each container and it is more reliable and flexible than doing the monitoring by Monit. So we removed the functionality of monitoring the critical processes by Monit.

How I did it
I removed the script process_checker and corresponding Monit configuration entries of critical processes.

How to verify it
I verified this on the device str-7260cx3-acs-1.
2021-06-04 10:16:53 -07:00
Renuka Manavalan
73447efc31
Add service to restore TACACS from old config (#7560)
Why I did it
In upgrade scenarios, where config_db.json is not carry forwarded to new image, it could be left w/o TACACS credentials.
Added a service to trigger 5 minutes after boot and restore TACACS, if /etc/sonic/old_config/tacacs.json is present.

How I did it
By adding a service, that would fire 5 mins after boot.
This service apply tacacs if available.

How to verify it
Upgrade and watch status of tacacs.timer & tacacs.service
You may create /etc/sonic/old_config/tacacs.json, with updated credentials
(before 5mins after boot) and see that appears in config & persisted too.

Which release branch to backport (provide reason below if selected)
 201911
 202006
 202012
2021-06-03 20:07:17 -07:00
Andriy Kokhan
6931a45ecf
Fixed typos in config-setup (#7754)
Signed-off-by: Andriy Kokhan <andriyx.kokhan@intel.com>
2021-06-03 08:59:38 -07:00
yozhao101
37863ac854
[Monit] Restart telemetry container if memory usage is beyond the threshold (#7645)
Signed-off-by: Yong Zhao yozhao@microsoft.com

Why I did it
This PR aims to monitor the memory usage of streaming telemetry container and restart streaming telemetry container if memory usage is larger than the pre-defined threshold.

How I did it
I borrowed the system tool Monit to run a script memory_checker which will periodically check the memory usage of streaming telemetry container. If the memory usage of telemetry container is larger than the pre-defined threshold for 10 times during 20 cycles, then an alerting message will be written into syslog and at the same time Monit will run the script restart_service to restart the streaming telemetry container.

How to verify it
I verified this implementation on device str-7260cx3-acs-1.
2021-05-28 11:13:44 -07:00
Renuka Manavalan
2cd61bc136
Invoke disk check periodically. (#7374)
Why I did it
Helps with periodic scan of disk for RO state.
If found, this script makes transient fix and raise error message.
2021-05-26 17:59:08 -07:00
shlomibitton
9930e738fe
Remove 'vm.panic_on_oom=1' (#7678)
#### Why I did it
If a process limits using nodes by mempolicy/cpusets, and those nodes become memory exhaustion status, one process may be killed by oom-killer.
No panic occurs in this case, because other node's memory may be free.
This means system total status may be not fatal yet.

#### How I did it
Remove 'vm.panic_on_oom=1' kernel flag from 'vmcore-sysctl.conf '
2021-05-24 17:23:49 -07:00
Alexander Allen
da7533aad4
[ntp] Fix ntp.conf template to allow setting of source port in CONFIG_DB (#7586)
Why I did it
Currently, there is a bug in the ntp.conf jinja2 template where it will ignore the src_intf directive in CONFIG_DB if there are multiple IP addresses associated with an interface. This code change fixes that bug and allows the template to select the correct source interface for NTP.

How I did it
I did this by modifying the macro in ntp.conf.j2 which determines if there is an ip address associated with an interface to set a state variable when it detects a valid interface entry in CONFIG_DB instead of outputting "true" directly (which could result in multiple "trues" outputted for interfaces with multiple valid IP addresses).

How to verify it
Add two ipv4 addresses to an interface in SONiC

Add the following configuration to config_db.json

{
"NTP": {
    "global": {
        "src_intf": "Ethernet1"
        }
    }
}
Replace Ethernet1 with the interface name of the one you assigned the IP addresses to.

Run sudo config reload -y

Open /etc/ntp.conf and verify that the following line exists

...
interface listen Ethernet1
...
The interface specified should be the one set in the previous steps.

Description for the changelog
[ntp] Fix ntp.conf template to allow setting of source port in CONFIG_DB
2021-05-23 13:40:43 -07:00
Sujin Kang
c6462577a9
add config-setup.service as dependency for pcie-check.service (#7599)
Why I did it
start pcie-check.service after config-setup.service since pcie_util depends on device_info which is available with config db metadata.

How I did it
Add config-setup.service as a dependency of pcie-check.service

How to verify it
Upon reboot, check if the pcie-check.sh throws the platform api error which is dependent on DEVICE_METADATA
2021-05-18 14:19:02 -07:00
Renuka Manavalan
7a575b3d00
[container_checker] Use Feature table to get running containers (#7474)
Why I did it
Finding running containers through "docker ps" breaks when kubernetes deploys container, as the names are mangled.

How I did it
The data is is available from FEATURE table, which takes care of kubernetes deployment too.

How to verify it
Deploy a feature via kubernetes and don't expect error from container_check.
2021-05-07 08:42:15 -07:00
xumia
56bdd750ab
Support readonly vtysh for sudoers (#7383)
Why I did it
Support readonly version of the command vtysh

How I did it
Check if the command starting with "show", and verify only contains single command in script.
2021-04-25 16:32:02 +08:00
Stepan Blyshchak
ae339c95d2
[systemd] disable default systemd udev rules for interfaces (#7369)
Fix #7364

99-default.link - was always in SONiC, but previous systemd (<247) had an issue and it did not work due to issue systemd/systemd#3374. Now systemd 247 works.

However, such policy overrides teamd provided mac address which causes teamd netdev to use a random mac
address. Therefore, needs to be disabled.

Signed-off-by: Stepan Blyschak <stepanb@nvidia.com>
2021-04-21 17:50:00 -07:00
Kuanyu Chen
01f2b5f250
[config-setup]: Fix a bug in checking if updategraph is enabled (#7093)
Encounter error during "config-setup boot" if the updategraph is enabled.

How I did it
Correct the code inside the config-setup script.
Remove the space between the assignment operator.

How to verify it
Remove the /etc/sonic/config_db.json and reboot the device.
Originally, it will return following error after boot up.
rv: command not found
After modification, it can correctly parse the status of updategraph without error.
2021-04-19 11:40:52 -07:00
jmmikkel
43342b33b8
[chassis] Add templates and code to support VoQ chassis iBGP peers (#5622)
This commit has following changes:

* Add templates and code to support VoQ chassis iBGP peers

* Add support to convert a new VoQChassisInternal element in the
   BGPSession element of the minigraph to a new BGP_VOQ_CHASSIS_NEIGHBOR 
   table in CONFIG_DB.
* Add a new set of "voq_chassis" templates to docker-fpm-frr
* Add a new BGP peer manager to bgpcfgd to add neighbors from the
  BGP_VOQ_CHASSIS_NEIGHBOR table using the voq_chassis templates.
* Add a test case for minigraph.py, making sure the VoQChassisInternal
  element creates a BGP_VOQ_CHASSIS_NEIGHBOR entry, but not if its
  value is "false".
* Add a set of test cases for the new voq_chassis templates in
  sonic-bgpcfgd tests.

Note that the templates expect the new
"bgp bestpath peer-type multipath-relax" bgpd configuration to be
available.

Signed-off-by: Joanne Mikkelson <jmmikkel@arista.com>
2021-04-16 11:11:32 -07:00
yozhao101
2737c9681f
[container_checker] Exclude the 'always_disabled' container from expected running container list (#7217)
Signed-off-by: Yong Zhao yozhao@microsoft.com

Why I did it
Since we introduced a new value always_disabled for the state field in FEATURE table, the expected running container list
should exclude the always_diabled containers. This bug was found by nightly test and posted at here: issue. This PR fixes #7210.

How I did it
I added a logic condition to decide whether the value of state field of a container was always_disabled or not.

How to verify it
I verified this on the device str-dx010-acs-1.

Which release branch to backport (provide reason below if selected)
 201811
 201911
 202006
[ x] 202012
2021-04-02 08:05:46 -07:00
Stepan Blyshchak
e179ec2fae
[services] introduce sonic.target (#5705)
- Why I did it
Group all SONiC services together and able to manage them together. Will be used in config reload command as much simpler and generic way to restart services.

- How I did it
Add services to sonic.target

- How to verify it
Together with Azure/sonic-utilities#1199
config reload -y

Signed-off-by: Stepan Blyshchak <stepanb@nvidia.com>
2021-02-25 14:26:24 +02:00
arlakshm
f77157f09d
[baseimage] add ipintutil in sudoer file (#6845)
show ip interfaces is enhanced recently to support multi ASIC platforms in this PR- https://github.com/Azure/sonic-utilities/pull/1396 .
The ipintutil script as to run as sudo user, to get the ip interface from each namespace.
Add this script to the sudoer file so that show ip interface command is available for user with read-only permissions

Signed-off-by: Arvindsrinivasan Lakshmi Narasimhan <arlakshm@microsoft.com>
2021-02-22 23:34:28 -08:00
Sujin Kang
d5238ae8dd
[pcie.yaml] Move pcie configuration file path to platform directory (#6475)
- Why I did it
The pcie configuration file location is under plugin directory not under platform directory.
#6437

- How I did it

Move all pcie.yaml configuration file from plugin to platform directory.
Remove unnecessary timer to start pcie-check.service
Move pcie-check.service to sonic-host-services
- How to verify it
Verify on the device
2021-02-21 08:27:37 -08:00
SuvarnaMeenakshi
5a49a0f499
[multi-asic][vs]: Update topology script to retrieve hwsku from minigraph (#6219)
Update topology script to retrieve hwsku from minigraph
if hwsku information is not available in config_db.
Fix clean up of interfaces in msft_multi_asic_vs hwsku
topology script.
- Why I did it
When bringing up multi-asic VS switch, topology service is started during boot up.
Topology service starts a shell script which runs the topology script present in /usr/share/sonic/device// directory. To invoke hwsku specific script, the topology script tries to retrieve hwsku information from config_db.
During initial boot up config_db might not be populated. In order to start topology service before config_db is updated,
update topology script to get hwsku information from minigraph.xml if it is available.
This will be helpful to bring up multi-asic VS testbed by loading minigraph and starting topology service.
- How I did it
Update topology.sh script to retrieve hwsku information from minigraph.xml.
Fix clean up function on msft_multi_asic_vs toplogy script.
- How to verify it
single-asic VS - no change; topology service is only enabled for multi-asic VS.
multi-asic VS - Bring up multi-asic VS image, copy minigraph to vs image, start topology service. Topology service should be successful.
to test clean up function fix, start topology service - make sure interfaces are created and moved to the right namespaces.
stop topology service - make sure namespace do not have any interface and all front end interfaces are present in default namespace.
2021-02-18 22:02:29 -08:00