- Why I did it
FW for Spectrum-4 ASIC not yet available
- How I did it
Remove in Mellanox fw make files to Spectrum-4 ASIC firmware binaries.
Remove from firmware upgrade scripts to be able Spectrum-4 ASIC.
- How to verify it
Run regression test
- Why I did it
To include latest fixes and new functionality
SDK/FW
1. Fixed bug in recovery mechanism in case of I2C error when trying to access the XSFP module.
2. On the NVIDIA Spectrum-2 switch, when receiving a packet with Symbol Errors on ports that are configured to cut-thought mode, a pipeline might get stuck.
3. On the Spectrum-2 and Spectrum-3 switch, if you enable ECN marking and the port is in split mode, traffic sent to the port under congestion (for example, when connecting two ports with a total speed of 50GbE to a single 25GbE port) is not marked.
4. Modifying existing entry/Adding new one when switch is at its maximum capacity (full by maximum allowed entries from any type such as routes, FDB, and so forth), will fail with an error.
5. When many ports are active (e.g., 70 ports up), and the configuration of shared buffer is applied on the fly, occasionally, the firmware might get stuck.
6. When a system has more than 256 ACL rules, on rare occasion, removing/adding rules may cause some ACL rules not to work.
7. On SN2201 system, on RJ45 port, the link might appear in 'down' state even if it operations properly.
8. Layer 4 port information is not initialized for BFD packet event. To address the issue, remote peer UDP port information was added in BFD packet event.
9. When setting LAG as a SPAN analyzer, the distributor mode of the LAG members was not taken into account. It may happen that the LAG member with distributor mode disabled will be set as a SPAN analyzer port.
- How I did it
Updated SDK/SAI submodule and relevant makefiles with the required versions.
- How to verify it
Build an image and run tests from "sonic-mgmt".
Signed-off-by: Volodymyr Samotiy <volodymyrs@nvidia.com>
- Why I did it
Add support for compiling Spectrum-4 ASIC firmware to the SONiC image
Add support for Spectrum-4 ASIC firmware upgrade
- How I did it
Update Mellanox fw make files to include Spectrum-4 ASIC firmware binaries.
Update firmware upgrade scripts to be able to detect Spectrum-4 ASIC.
- How to verify it
Run regression tests
Signed-off-by: Kebo Liu <kebol@nvidia.com>
- Why I did it
Update SDK/FW version - 4.5.3186/2010_3186 in order to have the following changes:
New functionality:
1. Added support for 6.5W (Class 8) in ports 49-50, 53-54, 57-58, and 61-62 on SN4600 system
Fix the following issues:
1. On very rare occasion (~1/100K), during I2C transaction with MMS1V50-WM and MMS1V90-WR modules on SN4700 system, the module may send unexpected stop which violate the I2C specification, possibly affecting the link up flow
2. When running 1GbE speeds on SN4600 system, the port remained active while peer side was closed
3. While toggling the cable with ‘sfputil lpmode on/off’, error msg like “ERR pmon#xcvrd: Receive PMPE error event on module 1: status {X} error type {y}” could be received
4. When toggling many ports of the Spectrum devices while raising 10GbE link up and link maintenance is enabled, the switch may get stuck and may need to be rebooted
5. When trying to reconfigure the Flex Parser header and Flex transition parameters after ISSU, the switch will returned an error even if the configuration was identical to that done before performing the ISSU
6. While moving from lossless to lossy mode while shared headroom was used, reduction of the shared headroom can only be done prior to pool type change and when shared headroom is not utilized
7. SLL configuration is missing in SDK dump
8. If TTL_CMD_COPY is used in Encap direction for a packet with no TTL, then the value passed in the ttl data structure will be used if non-zero (default 255 if zero)
9. PCI calibration changes from a static to a dynamic mechanism
10. Layer 4 port information is not initialized for BFD packet event. To address the issue, remote peer UDP port information was added in BFD packet event
11. SDK returned error when FEC mode is set on twisted pair, when FEC was set to None
- How I did it
Update pointer for the SDK/FW
- How to verify it
Run regression tests
Signed-off-by: dprital <drorp@nvidia.com>
- Why I did it
To include latest fixes and new functionality
SAI fixes and new features
fix#3205239, incorrect object type returned for SG child list
Fix VRF-VNI map entries remove issue
ECC health event and logging
[Port Buffers] restore default queue and pg configuration when all user pools are deleted
Fix EVPN type3 error on removal of uc/bc flood group
Fix EVPN type2 MAC move from local to remote results in SAI failure
Fix Disable learning on VXLAN tunnel
Fix error on VXLAN v6 tunnel removal
Fix port cannot apply schedule group when it is a lag member
Fix BFD add more detailed message on BFD packet not related to any existing session
gcc10 compilation fixes
Disable learning on VXLAN tunnel
Support BFD remote-disc exchange in negotiation stage
Tunnel Loopback packet action attribute implementation (for Dual TOR)
Add KVD resources MIN/MAX functionality (pending CRM issue with MIN only)
Support for CRC2 hash algorithm
Bulk counter support for PGs, queues
Support mirror sample rate attribute (SPC2+)
[Functional] [QoS] | Unable to remove SCHEDULE profile table even if there is no object referencing it
Next hop group optimized bulk API
Reduce verbosity of shared database already exists print
Span mirror policer (SPC2+), optimize pipeline for acl mirror action with policer on SPC2+
use same size descriptor pool for rx/tx
fix bfd - notify Sonic for admin-down event
2201 - empty list for supported fec for RJ45 ports
Fix don't disable used tunnel underlay interfaces
SDK fixes
100GbE FCI DAC (10137628-4050LF/HPE PN: 845408-B21) was recognized by mistake as supporting "cable burning' which caused the switch firmware to read page 0x9f (which unsupported in the cable) and to report this cable as having "bad eeprom".
Added remote peer UDP port information in BFD packet event.
After editing an ECMP, the resilient ECMP next-hop counter may not count correctly.
Fixed potential memory leaks in some APIs related to LPM
If TTL_CMD_COPY is used in Encap direction for a packet with no TTL, then the value passed in the ttl data structure will be used if non-zero (default 255 if zero).
In SN2201: When configuring Force mode, user should configure Speed and FEC on both sides
In Flex Tunnel encapsulation flow, if the encapsulation is with an IPv6 header, the flow label field may not be updated as expected.
In some cases, when changing speed to 400GbE over 8 lanes, the first few packets would be dropped.
In some traffic patterns involving small packets, the PortRcvErrors counter may mistakenly count events of local physical errors due to an internal flow in the hardware that involves link packets.
On Spectrum systems, sometimes during link failure, not all previous firmware indications cleared properly, potentially affecting the next link up attempt.
On the NVIDIA Spectrum-2 switch, when receiving a packet with Symbol Errors on ports that are configured to cut-thought mode, a pipeline might get stuck.
PCI calibration changes from a static to a dynamic mechanism.
SDK debug dump shows "Unknown" Counter in RFC3635 Counter Group.
SDK debug dump shows "Unknown" Counter in the PPCNT Traffic Class Counter Group.
SDK Dump missing column headers in some GC tables may result in difficulty understanding the dump.
SLL configuration is missing in SDK dump.
Spectrum-2 systems, do no support 1GbE on supported 40GbE modules.
When binding a UDP port which is already in use for BFD TX session, the error message appears incorrectly.
When Flex Tunnel was used, Flex Modifier sometimes experienced a brief mis-configuration during ISSU.
When many ports are active (e.g. 70 ports up), and the configuration of shared buffer is applied on the fly, occasionally, the firmware might get stuck.
When running 1GbE speeds on SN4600 system, the port remained active while peer side was closed.
When toggling many ports of the Spectrum devices while raising 10GbE link up and link maintenance is enabled, the switch may get stuck and may need to be rebooted.
When trying to reconfigure the Flex Parser header and Flex transition parameters after ISSU, the switch will returned an error even if the configuration was identical to that done before performing the ISSU.
While toggling the cable, and the low power mode is set to ON, an unexpected PMPE event error is received.
- How I did it
Updated SDK/SAI submodule and relevant makefiles with the required versions.
- How to verify it
Build an image and run tests from "sonic-mgmt".
Signed-off-by: Volodymyr Samotiy <volodymyrs@nvidia.com>
- Why I did it
Update SDK/FW version - 4.5.2320/2010_2320 in order to have the following fixes:
• Spectrum-3 | PCI calibration changes from a static to a dynamic mechanism.
• [VxLAN] TTL was set to 0 for non IP traffic (such as ARP)
- How I did it
Update pointer for the SDK/FW
- How to verify it
Run regression tests
- Why I did it
Update SDK/FW version - 4.5.2318/2010_2318 to pick up new fixes:
1. Cr space timeout on Hold and Release GW - at warm boot
2. Spectrum Port in stuck PHY_UP after peer side rebooted
3. Memory leak in sx_api_router_ecmp_update_set
- How I did it
Update the make file with the new version number
Update submodule Switch-SDK-drivers pointer
- How to verify it
Run sonic regression
Signed-off-by: Kebo Liu <kebol@nvidia.com>
- Why I did it
To include latest fixes:
1. Warmboot | When trying to reconfigure the Flex Parser header and Flex transition parameters after ISSU, the switch will returned an error even if the configuration was identical to that done before performing the ISSU.
2. Link Up | When toggling many ports of the Spectrum devices while raising 10GbE link up and link maintenance is enabled, the switch may get stuck and may need to be rebooted.
3. Shared buffer | While moving from lossless to lossy while shared headroom was used, reduction of the shared headroom can only be done prior to pool type change and when shared headroom is not utilized.
- How I did it
Updated SDK submodule along with the relevant Makefiles
- How to verify it
Build an image and run tests from "sonic-mgmt".
Signed-off-by: Volodymyr Samotiy <volodymyrs@nvidia.com>
Update SDK/FW to 4.5.1500/2010.1500 and SAI version to 1.21.1.1
SDK/FW features:
1. Added support for Finisar DR4 (FTCD4523E2PCM) on Spectrum-2 and Spectrum-3 systems.
SAI Features:
1. ECMP overlay support for IPv6
2. BFD offloading / 4K scale
3. Host interface user traps + improved trap registration (table entry)
4. gcc11 compilation fixes
5. Read support for ACL redirect action
6. Optimize ECMP DB size
7. Buffer descriptors new defaults
8. Updated port mapping for SN2201
SAI Fixes:
1. Debug counter removal when configured with all drop reasons
- Why I did it
Upgrade Mellanox SDK and SAI versions to latest
- How I did it
Updated submodule pointers
- How to verify it
Regression tested
- Why I did it
Update NVIDIA Copyright header to "mellanox" files which were changed since 1.1.2022
- How I did it
Update the copyright header
- How to verify it
Sanity tests and PR checkers.
- Why I did it
To include latest SDK fixes:
1. On CMIS modules, after low power configuration, the firmware waited for the module state to be ModuleReady instead of ModuleLowPower causing delays.
2. When connecting SN4600C, 100GbE port with CWDM4 module (Gen 3.0), link up time is 30 seconds.
and to include SAI fixes \ changes:
1. Reduce verbosity for resource check vendor data not found
2. Fix metadata validation, check default value on conditions check
3. Add 100MB, 10MB to 2201 system
4. L3 VXLAN overlay ECMP
5. VXLAN srcport API implementation
6. Fix scheduler profile null (default values) when set on sub group scheduler group
7. Fix ACL binding restoration when port leaves a LAG
8. Fix route logic for set next hop/action and reference counter for ECMP overlay
- How I did it
1. Updated SDK/FW submodule and relevant makefiles with the required versions.
2. Update SAI submodule and relevant makefile with the required version.
- How to verify it
Build an image and run tests from "sonic-mgmt".
- Why I did it
To include latest fixes.
SAI
1. Reclaim buffers for port which is admin down
2. Support for Spectrum-4 os Nvidia ASIC simulation
3. Support for SN2201
4. Fix host interface table entry, one channel per trap (fix sflow double registration)
5. 2 new queue counters - ecn marked packets + shared current occupancy
6. Fix storm policer unknown unicast
7. Add key/value for accuflow counters
8. Add MAC move
9. Add mirror congestion mode attribute
SDK
1. Under various circumstances, Ethernet ports falsely showed that InfiniBand cables were connected.
2. In SN4600C, at times, the link up time in both DAC and optics cables may, in the worst case, take up to 15 seconds.
3. Using SN4600C with copper or optics loopback cables in NRZ speeds, link may raise in long link up times
4. When ECMP has high amount of next-hops based on VLAN interfaces, in some rare cases, packets will get a wrong VLAN tag and will be dropped.
5. When connecting Spectrum devices with optical transceivers that support RXLOS, remote side port down might cause the switch firmware to get stuck and cause unexpected switch behavior.
6. Aggregation event is missing for WJH L2 drop reason 'Unicast egress port list is empty'.
7. Tying the SCL and SDA of the optical modules to 3.3V causes errors.
8. On SN4600, there was a delay of more than 10 seconds from the time a data packet is sent from CPU until it is transmitted through one of the switch ports.
9. While using SN4600C system with Finisar FTLC1157RGPL 100GbE CWDM4 modules, intermittent link flaps across multiple ports may be observed.
10. In Spectrum-2 and Spectrum-3 systems, link did not work in auto-negotiation when connected to Marvell PHY. KR mechanism has been enhanced to integrate with Marvell PHY.
11. The tunnel counter counts the drop packets now for Spectrum-2 and Spectrum-3 and consistent with Spectrum behavior and count the ECN dropped packets as well.
12. When connecting SN3800 to Cisco-9000, fast-linkup flow will fail and will rise in the normal flow.
13. Race condition in WJH library: when multiple threads load the LAG shared memory concurrently, the program may crash.
14. Add WJH L2 drop reason 'Unicast egress port list is empty' as a new drop reason.
15. Fixed a memory leak in sx_api_port_sflow_statistics_get API.
16. During initialization flow, the command interface that is used by the minimal driver and SDK caused the collision in the firmware since the same buffer is used in the firmware for the two interfaces.
17. Fix route issue on Kernel 5.10
- How I did it
Updated SDK/SAI submodule and relevant makefiles with the required versions.
- How to verify it
Build an image and run tests from "sonic-mgmt".
Signed-off-by: Volodymyr Samotiy <volodymyrs@nvidia.com>
Allow mellanox platform to build and successfully switch packets in
Debian 11
Upgraded
* Mellanox SDK
* Mellanox Hardware Management
* Mellanox Firmware
* Mellanox Kernel Patches
Adjusted build system to support host system running bullseye and
dockers running buster.
- Why I did it
Add NVIDIA Copyright header to "mellanox" files
- How I did it
Add NVIDIA Copyright header as a comment for Mellanox files
- How to verify it
Sanity tests and PR checkers.
- Why I did it
Update SDK\FW version to 4.4.3326\2008.3326. This version contains:
New Features:
1. Add support for Fast Boot for SN3800
Bug Fixing:
1. In some cases, when the total number of allocations exceeds the resource limit, an error can occur due to incorrect resource release procedure. This issue is most likely to affect the following resources: flow counters, ACL actions, PBS, WJH filter, Tunnels, ECMP containers, MC (L2 &L3)
2. On Spectrum systems, when using Async Router API with IPV6, an error message in the log regarding failing to remove ECMP container may show up. This error is not functional and can be safely ignored.
3. On Spectrum-2 systems and above, when using warm boot, setting max_bridge_num to a value greater than 1968 will cause an error and potential crash.
4. Some Molex cables do not support speed after reboot
- How I did it
- How to verify it
Was verified by running regression tests that includes complete sonic-mgmt tests supported
Update SDK\FW version to 4.4.3320\2008.3324. This version contains:
New Features:
* Add support for Fast Boot for SN3800
Bug Fixing:
* In some cases, when the total number of allocations exceeds the resource limit, an error can occur due to incorrect resource release procedure. This issue is most likely to affect the following resources: flow counters, ACL actions, PBS, WJH filter, Tunnels, ECMP containers, MC (L2 &L3)
* On Spectrum systems, when using Async Router API with IPV6, an error message in the log regarding failing to remove ECMP container may show up. This error is not functional and can be safely ignored.
* On Spectrum-2 systems and above, when using warm boot, setting max_bridge_num to a value greater than 1968 will cause an error and potential crash.
* Some Molex cables do not support speed after reboot
Signed-off-by: Dror Prital <drorp@nvidia.com>
Update FW version to 2008.3218, fixing the following issues:
- 50G/100G links that are operationally down before warm-reboot are not coming up after warm-reboot
- 50G/100G links with admin shut / no shut commands are not coming up after warm-reboot
Signed-off-by: Dror Prital <drorp@nvidia.com>
- Why I did it
* For SAI - Advance to adopt the following fixes:
1. Better handle not implement object type for resource availability
2. Fix ext dump when saidump is triggered from 2nd process (saidump utility) other than main adapter host (syncd in SONiC)
* For SDK\FW:
- Changes and new features:
1. Added support in SN4600C systems for new module Finisar ET7402-CWDM4 (100G CWDM4 QSFP28 1310nm SM 2KM).
2. Added support for new module MMS1W50-HM (2km transceiver FR4) for 200GbE
3. Improved performance of "per-port-buffer" counters
4. Added support for Kernel 5.10
- Bugs fixes:
On rare occasions (0.5%), in SN4600C systems, when using 100GbE NRZ mode and Fastboot flow, the link up time may take up to 10 seconds
Signed-off-by: Dror Prital <drorp@nvidia.com>
Why I did it
* For SAI - Upgrade to Version 1.19.0
- Add support for VxLAN encap TTL uniform model on SPC2/3
- Add ACL entry actions set VRF, set do no learn, add VLAN ID, add VLAN priority
- Add ACL field has VLAN tag
- Bulk counters (improve port statistics performance)
- Create async dump extra as part of debug generate dump
- Create irisc dump on severe health event
- Support 0 port systems (modify get switch mac to work accordingly)
- Set interface vlan up state for ping tool in SONiC
- Support attributes SAI_PORT_ATTR_QOS_SCHEDULER_PROFILE_ID, SAI_PORT_ATTR_QOS_INGRESS_BUFFER_PROFILE_LIST,
SAI_PORT_ATTR_QOS_EGRESS_BUFFER_PROFILE_LIST, SAI_PORT_ATTR_POLICER_ID as part of port create Git stats
* For SDK\FW - Upgrade to Version SDK 4.4.3106, FW 2008_3110
Added Features:
- Increased ACL table
- Enhanced PSAMPLE support
- Added support for Finisar SR4 module in SN3700 systems
- Added support for Python 3.0 in examples.
Fix bugs:
- On LR4 transceivers 00YD278, the firmware incorrectly identified the transceiver
- Reduce memory consumption for virtual LAG
- Fixed PSAMPLE listeners cleanup on SDK drivers unloading.
- On Spectrum-2 and Spectrum-3 systems, slow reaction time to Rx pause packets may lead to buffer overflow on servers.
- BER may be experienced when using 5m DAC cables between SN4700 and SN2700 in 100GbE speed.
- On very rare occasion, when connecting DR4 PAM4 transceiver to 100GbE DR1 NRZ, low BER may be experienced.
- Unexpected packet drops on the port ingress buffer may be experienced when working in 400GbE mode.
Note: When performing ISSU from an older version, this fix won't be applied. For fix to apply, a non-ISSU reset is required.
- Fix SN3800 specific warm boot scenario: Disable interface, Warm Boot, Enable Interface --> link will remain down.
Signed-off-by: Dror Prital <drorp@nvidia.com>
- Why I did it
Updated FW to xx.2008.2526 version.
Fixed issues:
1. Spectrum-2, Spectrum-3 | sFlow | High CPU load and high on fully loaded switch.
2. Spectrum-2, Spectrum-3 | Fine grain LAG | in rare cases doesn’t update the right entry
- How I did it
Updated submodule pointer and version in a Makefile.
- How to verify it
Full regression and bugs validation
Signed-off-by: Shlomi Bitton <shlomibi@nvidia.com>
New features and fixes in the new SDK/FW:
SN4600C | AN/LT support
SN2700 | AN/LT bugs fixes
WJH | FID_MISS support
Signed-off-by: Kebo Liu <kebol@nvidia.com>
Fix the following issues:
Spectrum-2, Spectrum-3 | Port | Fix link issue when using 25 GbE rate between two ports while one is on Spectrum-2-based system and the other is on Spectrum-3-based system
All | warmboot | fail to upgrade from earlier SONiC versions with official SDK/FW 4.4.2306 (was on SONiC 201911)
All | What-Just-Happened | When enabling or disabling WJH under high traffic load to the host CPU, in very specific and low probability conditions, an error could occur, that may result in loss of data, channel failure or in extreme cases SW failure
Signed-off-by: Volodymyr Samotiy <volodymyrs@nvidia.com>
- Why I did it
To pick up new features and fix from SDK/FW and SAI
SDK/FW new Feature:
All | Added support for multiple modules and cable types. For full list contact Nvidia networking support
Spectrum-3 | SN46000C | Added support for up to 5W on ports 49 to 64 .
SDK/FW bugs' fix:
All | fast reboot | fast boot failure from latest 201811 to 201911 and above
Spectrum | 10GbE/1GbE Transceiver (FTLX8574D3BCV) stopped working after firmware upgrade
Spectrum-2 | When device is rebooted with locked Optical Transceivers in split mode, the firmware may get stuck
Spectrum-2 | SN3700 | When connecting at 200GbE to Ixia K400, Ixia receives CRC errors
Spectrum-2 | SN3800 | On rare occasions packets loss may be experienced due to signal integrity issues
Spectrum-2 | When the port is a member of a LAG, after a warmboot and port toggle on the peer-side, the port remains down
Spectrum-3 | SN4700 | While using Optic cable in Split 4x1 mode in PAM4, when two first ports are toggled, the other 2 ports go down
Spectrum-3 | SN4700 | When working in 400GbE, deleting the headroom configuration (changing buffer size to zero) on the fly may cause continual packet drops
SAI
All | sFlow | Use hardcoded value 1 as netlink group number ax expected by hsflowd
- How I did it
Update the related version number in the make files and update the submodule pointer accordingly.
- How to verify it
Run regression test and everything works good.
To have the following fixes:
* All | Port status remains down after warm boot and flapping the port on peer side
* All | LAG HASH | IPv6 SRC_IP is not accounted in LAG hashing [
* All | ASIC driver | Kernel crash observed when driver reload is initiated before it fully loaded
* Spectrum-3 | Buffer | In lossless configuration, headroom is been evicted only when the shared buffers is free
* All | prevent FW access during ISSU
Signed-off-by: Volodymyr Samotiy <volodymyrs@nvidia.com>
Bugs fixes:
All | Kernel | During system reload when CPU is loaded with heavy traffic, a Kernel Panic may occur.
All | Modules, Port split | FW stuck when device rebooted with locked Optical Transceivers in split mode
Spectrum-3 | PFC | On Spectrum-3 systems, slow reaction time to Rx pause packets on 40GbE ports may lead to buffer overflow on servers.
Spectrum-3 | SN4700, Port Split | On rare occasion SN4700, conducting 100G split (4x25G) in NRZ when splitter port 1 or 2 are down, ports 3 and 4 will also go down.
Enahncments:
All | Kernel | new notification on ISSU start, so other kernel drivers can disable any interface to ASIC
Signed-off-by: Kebo Liu <kebol@nvidia.com>
Features:
Spectrum-3 | Systems | Added GA-level support for SN4700 A0 system
All | Shared headroom | Added GA-level support for Shared headroom between PGs
Bugs fixes:
All | Counters | Sent traffic in certain size is wrongly increase to a smaller size counter, because port extended counter has a counter for sent traffic per packet-size range
All | Shared buffer | Configuring shared buffer on the fly may, on occasion, cause the chip to get stuck
Spectrum-2 | Modules | On occasion, link down is experienced with INPHI COLORZ PAM4 100G optic cables on SN3700 systems
* [Mellanox] Update SAI to 1.18.0
* [Mellanox] Update SDK to 4.4.2112
* Updated Mellanox SAI to 1.18.0.2
* Updated bcmsai debians to use SAI 1.7.1
* Updated Mellanox to use SAI 1.7.1
* Updated submodule sonic-sairedis using SAI 1.7.1
Co-authored-by: Vineet Mittal <vmittalmittal@microsoft.com>
Co-authored-by: Nazarii Hnydyn <nazariig@nvidia.com>
- SN3800 vs Cisco9236 - no link copper or optics - start sending IDLE before PHY_UP for specific OPNs
Signed-off-by: Nazarii Hnydyn <nazariig@nvidia.com>
* Update sonic-sairedis (sairedis with SAI 1.6 headers)
* Update SAIBCM to 3.7.4.2, which is built upon SAI1.6 headers
* missed updating BRCM_SAI variable, fixed it
* Update SAIBCM to 3.7.4.2, updated link to libsaibcm
* [Mellanox] Update SAI (release:v1.16.3; API:v1.6)
Signed-off-by: Volodymyr Samotiy <volodymyrs@mellanox.com>
* Update sonic-sairedis pointer to include SAI1.6 headers
* [Mellanox] Update SDK to 4.4.0914 and FW to xx.2007.1112 to match SAI 1.16.3 (API:v1.6)
Signed-off-by: Volodymyr Samotiy <volodymyrs@mellanox.com>
* ensure the veth link is up in docker VS container
* ensure the veth link is up in docker VS container
* [Mellanox] Update SAI (release:v1.16.3.2; API:v1.6)
Signed-off-by: Volodymyr Samotiy <volodymyrs@mellanox.com>
* use 'config interface startup' instead of using ifconfig command, also undid the previous change'
Co-authored-by: Volodymyr Samotiy <volodymyrs@mellanox.com>
Update SAI/SDK/FW and MSN4700 device files to support 8 lanes 400G
Update SAI to 1.16.3
Update SDK to 4.4.0914
Update FW to *.2007.1112
Update MSN4700 device files to support 8 lanes 400G
update FW to xx_2000_3298
update SAI to 1.16.0
update Spectrum-1 and Spectrum-2 buffer pool size according to the new SDK default config change.
modified: ../../device/mellanox/x86_64-mlnx_msn2700-r0/ACS-MSN2700/buffers_defaults_t0.j2
modified: ../../device/mellanox/x86_64-mlnx_msn2700-r0/ACS-MSN2700/buffers_defaults_t1.j2
modified: ../../device/mellanox/x86_64-mlnx_msn3700-r0/ACS-MSN3700/buffers_defaults_t0.j2
modified: ../../device/mellanox/x86_64-mlnx_msn3700-r0/ACS-MSN3700/buffers_defaults_t1.j2
modified: fw.mk
modified: mlnx-sai.mk
modified: mlnx-sai/SAI-Implementation
modified: sdk-src/sx-kernel/Switch-SDK-drivers
modified: sdk.mk
signed-off by kebol@mellanox.com