Prevent system-healthd from service from failing at boot time due to missing configuration.
Also adds basic support for healthd.
The following caveat exists with this placeholder configuration:
- No PSU monitoring (sensors/fans)
- No ASIC temperature monitoring
platform.json is needed for sonic-mgmt testing. Also in the future it will be used as part of dynamic port breakout.
Also removed the folder symlink for BlackhawkDD because it has a different platform.json than BlackhawkO.
Co-authored-by: Zhi Yuan Carl Zhao <zyzhao@arista.com>
Current support for the 7060PX4-32 and 7060DX4 was broken.
With this change, ports are now linking fine.
Co-authored-by: Zhi Yuan Carl Zhao <zyzhao@arista.com>
- Enable thermalctld support for our platforms
- Fix Chassis.get_num_sfp which had an off by one
- Implement read_eeprom and write_eeprom in SfpBase
- Refactor of Psus and PsuSlots. Psus they are now detected and metadata reported
- Improvements to modular support
Co-authored-by: Zhi Yuan Carl Zhao <zyzhao@arista.com>
This is to fix pcie firmware check assert in Broadcom SDK once the SAI changes merges. This will be in the future but adding the soc property in the broadcom config now.
Co-authored-by: Zhi Yuan Carl Zhao <zyzhao@arista.com>
However in SAI 3.7 default behaviout got changes to 128 Group and 128
Memeber each.
This change is to make sure we are using same ECMP Group/Memeber Per
Group for 3.7 also so that behaviour is consistent.
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
thermalctld throwing error messages because it is not yet fully configured, disabling it for now on arista platforms.
Co-authored-by: Zhi Yuan Carl Zhao <zyzhao@arista.com>
* Fix showing systemd shutdown sequence when verbose is set
* Fix creation of kernel-cmdline file
Sometimes boot0 prints error
"mv: can't preserve ownership of '/mnt/flash/image-arsonic.xxxx/kernel-cmdline': Operation not permitted"
* Improve flash space usage during installation
Some older systems only have 2GB of flash available. Installing a second
image on these can prove to be challenging.
The new installation process moves the installer swi to memory in order
to avoid free up space from the flash before uncompressing it there.
It removes all the flash space usage spike and also improves the IO
since the installation is no more reading and writting to the flash at
the same time.
* Add support of 7060CX-32S-SSD
* 7260CX3: use inventory powerCycle procedures
* 7050QX-32S: use inventory powerCycle procedures
* 7050QX-32: use inventory powerCycle procedures
* platform: arista: add common platform_reboot
Replace platform_reboot by a link to new common for devices already
using a similar script.
* 7060CX-32S: use inventory powerCycle procedures
* Install python smbus in pmon
Some platform plugin need the python smbus library to perform some actions.
This installs the dependency.