Update AS7312-54X,AS7312-54XS,AS7315-27XB config.bcm file to make sure there is no the following error message.
configuration: format error in /usr/share/sonic/hwsku/th-as7312-48x25G+6x100G.config.bcm on line 110 (ignored)#15
Modify get_psu_presence(). Move read() and close() to "try: ... except IOError:" To avoid when read
port present sysfs fail. This exception will let sfputil.py to exit. So "sfputil show eeprom" can't show other port status.
This switch has 27 fiber ports, 4x25G, 20x10G , and 3x100G ports ports.
CPU: Intel ® Atom™ Processor C3508,1.6GHz
BMC: None
MAC: Broadcom BCM88470 (Qumran AX).
MISC: Support IEEE1588v2, hot-swappable PSU, hot-swappable fan tray.
But notice here, BCM88470 is not supported for SAI now.
So the syncd container is not running so far.
Signed-off-by: roy_lee <roy_lee@accton.com>