Why I did it
Change the mirror config file
Use the files/build/versions/default/versions-mirror only when reproducible build enabled.
The config in files/build/versions is only for reproducible build, while snapshot mirror feature does not have the dependency on the reproducible build.
How I did it
Skip the mirror config in files/build/versions/default/versions-mirror if reproducible build not enabled.
How to verify it
Why I did it
advance sonic-platform-daemons
7219b56 - [Xcvrd]: Fix optics insertion/removal not detected (Add Ingrasys S9100 platform submodule #333) (3 days ago) [Prince George]
9b15ccf - add data for telemtery enhancement for 'active-active' cable type ([platform]: add support for Force10-Z9100 32x100G #332) (3 days ago) [vdahiya12]
1c7dba6 - Fix bug where transceiver info is missing after port breakout change ([teamd] Fix a bug in #305 that will break teamd #329) (3 days ago) [Tal Berlowitz]
07b8f3c - Xcvrd should restart if any child thread crashes (Update Mellanox SAI git reference #326) (3 days ago) [mihirpat1]
How I did it
How to verify it
Why I did it
advance sonic-platform-common
2dbc0ea - (HEAD, origin/202211) Change get_tx_bias return type to list ([platform]: add eeprom/sfputil support for z9100 #342) (2 days ago) [mihirpat1]
How I did it
How to verify it
Changing the default config knob value to be True for killing radv, due to the reasons below:
Killing RADV is to prevent sending the "cease to be advertising interface" protocol packet.
RFC 4861 says this ceasing packet as "should" instead of "must", considering that it's fatal to not do this.
In active-active scenario, host side might have difficulty distinguish if the "cease to be advertising interface" is for the last interface leaving.
6.2.5. Ceasing To Be an Advertising Interface
shutting down the system.
In such cases, the router SHOULD transmit one or more (but not more
than MAX_FINAL_RTR_ADVERTISEMENTS) final multicast Router
Advertisements on the interface with a Router Lifetime field of zero.
In the case of a router becoming a host, the system SHOULD also
depart from the all-routers IP multicast group on all interfaces on
which the router supports IP multicast (whether or not they had been
advertising interfaces). In addition, the host MUST ensure that
subsequent Neighbor Advertisement messages sent from the interface
have the Router flag set to zero.
sign-off: Jing Zhang zhangjing@microsoft.com
Why I did it
include changes from sairedis submodule
102d20b | [202211][submodule][SAI]Advance header include 0031470 | improve enum values integration check (#1727) (#1737)
04d3c41 | [Submodule][upgrade]Upgrade SAI submodule (#1204)
updates from SAI
7710e24 | [cherry-pick][202211]Enhance the check enum lock script (#1741) (#1742)
0031470 | improve enum values integration check (#1727) (#1737)
4f11c7e | Enable github code scanning to replace LGTM. (#1709)
How I did it
How to verify it
During docker build, host files can be passed to the docker build through
docker context files. But there is no straightforward way to transfer
the files from docker build to host.
This feature provides a tricky way to pass the cache contents from docker
build to host. It tar's the cached content and encodes them as base64 format
and passes it through a log file with a special tag as 'VCSTART and VCENT'.
Slave.mk in the host, it extracts the cache contents from the log and stores them
in the cache folder. Cache contents are encoded as base64 format for
easy passing.
<!--
Please make sure you've read and understood our contributing guidelines:
https://github.com/Azure/SONiC/blob/gh-pages/CONTRIBUTING.md
** Make sure all your commits include a signature generated with `git commit -s` **
If this is a bug fix, make sure your description includes "fixes #xxxx", or
"closes #xxxx" or "resolves #xxxx"
Please provide the following information:
-->
#### Why I did it
#### How I did it
#### How to verify it
Eariler the SDK stat polling was erroneously set to once every msec
which is far more frequent than required by SWSS. The new setting, which
is consistent with other vendor SKUs, is once a second. The net result
is reduced CPU MHz by syncd.
Why I did it
fix DX010 fan drawer and watchdog platform test case issues
How I did it
1. Add fan_drawer get_maximum_consumed_power support
2. Adjust maximum watchdog timeout value check
How to verify it
Run test_fan_drawer and test_watchdog test cases.
* [Security] Upgrade the openssl version to 1.1.1n-0+deb11u4+fips (#13737)
Why I did it
[Security] Upgrade the openssl version to 1.1.1n-0+deb11u4+fips
f6df7303d8 Update expired certs.
84540b59c1 CVE-2022-2068
f763d8a93e Prepare 1.1.1n-0+deb11u2
576562cebe CVE-2022-1292
How I did it
Upgrade the OpenSSL version
* [Security] Upgrade OpenSSL version for armhf
Adding /usr/local/bin/storyteller to READ_ONLY_CMDS. So no write access or prompt for password is needed to run storyteller.
Tested on 202205 clusters, user who didn't request write access was able to grep log using storyteller.
sign-off: Jing Zhang zhangjing@microsoft.com
Why I did it
This PR is an enhancement of PR #13105
Because the input string of AttachTo for ACL table can appear in both port name group and port alias group, I added a logic to determine whether the string should be port name or port alias
If all the input strings belong to port name group, then we treat all of them as port name
If all the input strings belong to port alias, then we treat all of them as port alias
If all the input string belongs to both port alias group and port name group, we prefer port alias. The behavior is as before.
How I did it
Walk through all port names/alias in the input to make a decision.
How to verify it
Verified by adding UT.
#### Why I did it
Back port GNMI to 202211 branch
#### How I did it
Update rules/config to enable host service
#### How to verify it
Run GNMI end2end test
Why I did it
If make fails, we can't rerun the make process, because existing patches can't apply again.
How I did it
Check if patches are applied. if yes, don't apply patches again.
How to verify it
Why I did it
There is a queue in sysmonitor.py that is created based on an object of multiprocessing.Manager.
After performing fast-reboot, system health monitor is being shut down, what causes this Manager to be shut down as well, since it is a child-process of healthd.
That's why I moved the creation of this Manager from the top of the file to the function Sysmonitor.system_service() (The only place it is used), to make Manager a child-process of Sysmonitor, instead of Healthd. This way both the queue (the Manager) and the processes that uses this queue will be child-processes of the same process, and the problematic scenario of sysmonitor sending messages to a dead queue will not be possible.
How I did it
Removed the definition of manager as global and moved it to system_service() function
How to verify it
Perform a fast reboot and verify the traceback issue is fixed
- Why I did it
This optimization is needed for DPU SONiC. DPU SONiC runs a limited set of containers and teamd and radv containers are not part of them. Unlike the other containers, there was no possibility to disable teamd and radv containers compilation.
To reduce DPU SONiC compilation time and reduce the image size this commit adds the possibility to disable their compilation.
- How I did it
Two new configuration options are added to rules/config file:
INCLUDE_TEAMD
INCLUDE_ROUTER_ADVERTISER
By default to preserve the existing behavior both options are enabled. There are two ways to override them:
To change option value to "n" in rules/config file.
To override their value using SONIC_OVERRIDE_BUILD_VARS env variable:
SONIC_OVERRIDE_BUILD_VARS="SONIC_INCLUDE_TEAMD=y SONIC_INCLUDE_ROUTER_ADVERTISER=n"
- How to verify it
The default behavior is preserved. To verify it compile the image without overriding new options. Install the image and verify that both teamd and radv containers are present and running.
To verify the new options override them with "n" value. Compile and install image. Verify that no docker containers are present. Verify that SWSS can start without errors.
Why I did it
Fix the following issues for Seastone platform:
- system-health issue: show system-health detail will not complete #9530, Celestica Seastone DX010-C32: show system-health detail fails with 'Chassis' object has no attribute 'initizalize_system_led' #11322
- show platform firmware updates issue: Celestica Seastone DX010-C32: show platform firmware updates #11317
- other platform optimization
How I did it
Modify and optimize the platform implememtation.
How to verify it
Manual run the test commands described in these issues.
- Why I did it
Fixed sflow yang model to include collector_vrf field.
- How I did it
Added leaf for collector_vrf under sflow_collector. Additionally aligned the configuration guide
- How to verify it
Added UT to verify.
Debian is shipping a systemd timer unit for logrotate, but we're also
packaging in a cron job, which means both of them will run, potentially
at the same time. Remove our cron file, and add an override to the
shipped timer file to have it be run every 10 minutes.
Fixes#12392.
Signed-off-by: Saikrishna Arcot <sarcot@microsoft.com>
Signed-off-by: Saikrishna Arcot <sarcot@microsoft.com>
Why I did it
To ensure, that after a BGP startup, dualtor T0 receives BGP updates before sending out BGP updates.
Please refer to sonic-net/SONiC#1161 for more details.
How I did it
add coalesce-time 10000 to the frr bgp startup config.
Signed-off-by: Longxiang Lyu <lolv@microsoft.com>
Why I did it
We plan to pilot k8s feature, need to fix several bugs including enable telemetry feature and add platform label.
How I did it
Add support feature set, only enable telemetry container upgrade for now
Add platform label for scheduler usage
Remove CNI installation code, it would be auto installed when install kubeadm
How to verify it
After sonic device join k8s cluster, show node labels to check if platform label is visible.
Signed-off-by: Yun Li yunli1@microsoft.com
#### Why I did it
Improve naming convention for bgp notification events and change type of leaf for sonic-events-host mem usage from uint64 to decimal64
#### How I did it
Replace "-" with "_"
Replace uint64 with decimal64
#### How to verify it
Run yang model unit tests
#### Description for the changelog
Change YANG model leaf naming convention for bgp notification
Why I did it
Fix issue caused by dualtor support PR [dhcpmon] Open different socket for dual tor to enable interface filtering #11201
Improve code
How I did it
On single ToR, packets received count was duplicated due to socket filter set to "inbound"
Tx count not increasing due to filter set to "inbound". Added an outbound socket to count tx packets
Added vlan member interface mapping for Ethernet interface to vlan interface lookup in reference to PR Fix multiple vlan issue sonic-dhcp-relay#27
Exit when socket fails to initialize to allow dhcp_relay docker to restart
How to verify it
Tested on vstestbed single tor and dual tor, sent packets and verify printed out dhcpmon rx and tx counters is correct
Correct number of tx increases
Tx does not increase when ToR is on standby
#### Why I did it
Segfault was occuring when running memory_checker
#### How I did it
Deinit publisher immediately after publishing
#### How to verify it
Manual testing
Why I did it
This is to fix test_forward_ip_packet_with_0xffff_chksum_tolerant test failure on 720DT-48S. IP packets with checksum set to 0xffff will be forwarded with the same checksum on this platform, instead of updating to the correct value.
How I did it
Add bcm config sai_verify_incoming_chksum=0 so that checksum is updated instead of being left unchanged when checksum is 0xffff. Note that packets with invalid checksum are still dropped with this config.
Why I did it
This PR is to update minigraph.py to support both port alias and port name as input of AttachTo attribute of ACL table.
Before this change, only port alias is supported.
How I did it
Add a global variable to store port names
Search both port names and port alias wheh parsing the value of AttachTo.
How to verify it
Verified by a new unit test case test_minigraph_acl_attach_to_ports
Verified by copying the new minigraph.py to a testbed and run conflg load_minigraph.
Why I did it
Currently the config cli of dhcpv4 is may cause confusion and config of dhcpv6 is missing.
How I did it
Add dhcp_relay config cli and test cases.
config dhcp_relay ipv4 helper (add | del) <vlan_id> <helper_ip_list>
config dhcp_relay ipv6 destination (add | del) <vlan_id> <destination_ip_list>
Updated docs for it in sonic-utilities: https://github.com/sonic-net/sonic-utilities/pull/2598/files
How to verify it
Build docker-dhcp-relay.gz with and without INCLUDE_DHCP_RELAY, and check target/docker-dhcp-relay.gz.log
- Why I did it
In order to prevent the sonic-mgmt/tests/platform_tests/sfp/test_sfputil.py test failing on the log analyzer step.
The mentioned test is performing the sfputil reset EthernetX for every interface on the SONiC switch, this action will flap the SFP device status (INSTERTED -> REMOVED -> INSTERTED).
The SONiC XCVRD daemon will catch this SFP device status change (because it is monitoring the presence status of the cable).
To judge the cable presence status, currently, we are still leveraging to read the first bytes of the EEPROM, and the EEPROM could be not ready at some moment and the SONiC XCVRD daemon will print the error log to Syslog:
ERR pmon#xcvrd: Error! Unable to read data for 'xx' port, page 'xx' offset 128, rc = 1, err msg: Sending access register
- How I did it
Change logging severity from ERR to WARNING
- How to verify it
Run the sonic-mgmt/tests/platform_tests/sfp/test_sfputil.py
OR much faster way to run the next script on the switch:
#!/bin/bash
START=0
END=248
for (( intf=$START; intf<=$END; intf+=8))
do
sfputil reset Ethernet"${intf}"
done
sfputil show presence
- Why I did it
Remove TODO comments which are no longer needed
- How I did it
Remove TODO comments which are no longer needed
- How to verify it
Only comment change