- Why I did it
Split and bulk counter bug fixes:
Init port auto neg to default on static (SAI XML) port split for 2nd+ port
- How I did it
Update submodule hash pointer.
- How to verify it
Verify the above is handled properly and reported issues are assumed to be fixed.
Signed-off-by: Shlomi Bitton <shlomibi@nvidia.com>
- Why I did it
Remove EEPROM cache file and use DB instead
- How I did it
Read EEPROM data from DB if possible
If data is not ready in DB, read from hardware using a visitor pattern
- How to verify it
Manual test and regression
- Why I did it
This is to back-port Azure 7410 to 202012 branch.
Enhance the Python3 support for platform API. Originally, some platform APIs call SDK API which didn't support Python 3. Now the Python 3 APIs have been supported in SDK 4.4.3XXX, Python3 is completely supported by platform API
- How I did it
Start all platform daemons from python3
1. Remove #/usr/bin/env python at the beginning of each platform API file as the platform API won't be started as daemons but be imported from other daemons.
2. Adjust SDK API calls accordingly
Signed-off-by: Stephen Sun <stephens@nvidia.com>
- Why I did it
Adjust the Makefile for SDK/python-SDK-API to support both python2 and python3
- How to verify it
Build the image and check whether python2 and python3 are both supported by SDK API.
Signed-off-by: Stephen Sun <stephens@nvidia.com>
Signed-off-by: Yong Zhao yozhao@microsoft.com
Why I did it
Currently we leveraged the Supervisor to monitor the running status of critical processes in each container and it is more reliable and flexible than doing the monitoring by Monit. So we removed the functionality of monitoring the critical processes by Monit.
How I did it
I removed the script process_checker and corresponding Monit configuration entries of critical processes.
How to verify it
I verified this on the device str-7260cx3-acs-1.
This is due to the fact that we use SONIC_OVERRIDE_BUILD_VARS internally
in our build jobs and this is not accounted in caching framework.
So we add MLNX_SDK_DEB_VERSION to force rebuild if we changed it via
SONIC_OVERRIDE_BUILD_VARS.
Signed-off-by: Stepan Blyschak <stepanb@nvidia.com>
- Why I did it
Update FW version to 2008_3110 fixing SN3800 specific warm boot scenario:
1. Disable interface
2. Warm Boot
3. Enable Interface --> link will remain down.
- How I did it
Use new FW that contains the fix for the problem mentioned above
- How to verify it
Run the scenario mentioned above and make sure that the link is up after warm boot
Signed-off-by: Dror Prital <drorp@nvidia.com>
#### Why I did it
According to thermalctld hld, each fan must belong to a fan drawer, if the fan drawer does not physically exist, put fan into a virtual fan drawer. This PR is to clear fan from chassis._fan_list
#### How I did it
1. Don't put fan to chassis._fan_list
2. Always query fan from fan_drawer
- Why I did it
Pick up fix from new hw-management package:
Fix gearbox thermal zone name, which was lack suffix thermal zone number
- How I did it
Update the hw-management version number in the make file
Update hw-management submodule pointer
- How to verify it
Run platform related test cases on Mellanox platform
- Why I did it
Updated FW to xx.2008.2526 version.
Fixed issues:
1. Spectrum-2, Spectrum-3 | sFlow | High CPU load and high on fully loaded switch.
2. Spectrum-2, Spectrum-3 | Fine grain LAG | in rare cases doesn’t update the right entry
- How I did it
Updated submodule pointer and version in a Makefile.
- How to verify it
Full regression and bugs validation
Signed-off-by: Shlomi Bitton <shlomibi@nvidia.com>
#### Why I did it
Adopt a single way to get fan direction for all ASIC types.
It depends on hw-mgmt V.7.0010.2000.2303. Depends on https://github.com/Azure/sonic-buildimage/pull/7419
#### How I did it
Originally, the get_direction was implemented by fetching and parsing `/var/run/hw-management/system/fan_dir` on the Spectrum-2 and the Spectrum-3 systems. It isn't supported on the Spectrum system.
Now, it is implemented by fetching `/var/run/hw-management/thermal/fanX_dir` for all the platforms.
Signed-off-by: Stephen Sun <stephens@nvidia.com>
- Why I did it
To include below changes:
Set monitoring VLAN hostif up dy default (for VNET ping tool)
- How I did it
Updated SAI submodule pointer
- How to verify it
Create VLAN hostif according to changes in PR: Azure/sonic-swss#1645
Verify it is admin up by default
Signed-off-by: Volodymyr Samotiy <volodymyrs@nvidia.com>
The following error message is observed during chassis object being destroyed
"Exception ignored in: <function Chassis.__del__ at 0x7fd22165cd08>
Traceback (most recent call last):
File "/usr/local/lib/python3.7/dist-packages/sonic_platform/chassis.py", line 83, in __del__
ImportError: sys.meta_path is None, Python is likely shutting down
The chassis tries to import deinitialize_sdk_handle during being destroyed for the purpose of releasing the sdk_handle.
However, importing another module during shutting down can cause the error because some of the fundamental infrastructures are no longer available."
This error occurs when a chassis object is created and then destroyed in the Python shell.
- How I did it
To fix it, record the deinitialize_sdk_handle in the chassis object when sdk_handle is being initialized and call the deinitialize handler when the chassis object is being destroyed
- How to verify it
Manually test.
- Why I did it
Upgrade hw-mgmt to 7.0100.2303
Bug fixes
1. Fan direction feature fix for fixed FAN system (using shell instead of binutils/strings)
2. Remove cpld 4th link on systems with only 3 CPLD's
3. hw-mgmt: thermal: Add hardcoded critical trip point. Follow-up after patch "Removing critical thermal zones to prevent unexpected software system shutdown".
4. Fix sensor attribute mapping to be label based instead of index based to allow common handling of voltage regulator names independently of hardware changes.
5. Update 'lm-sensors' custom configuration file. Relevant only for users utilizing sensors.conf files coming along with hw-management package.
6. For full feature list please follow https://github.com/Mellanox/hw-mgmt/blob/V.7.0010.2300_BR/debian/Release.txt
- How I did it
Update hw-mgmt pointer
Remove unused patches
Fix existing patch to make sure it apply successfully
- How to verify it
Full platform regression on all mellanox platforms
- Why I did it
Changes in the new release:
1. Fix 10G and 50G speeds in SAI XML to support all interface types
2. Enable SMAC=DMAC and SMAC MC in tunnel debug counter
3. Add tunnel statistics
4. Add isolation group API implementation
5. Fix ACL ANY debug counter to correctly track ACL drops
6. Add VXLAN source port hard coded range, controlled by K/V
7. FW dump me now feature
8. Add mlxtrace to saidump
9. Speed lane setting and AN control
10. Implement query stats API
11. VNI miss part of tunnel decal drop reason
- How I did it
Update the version number in SAI make file, update the mlnx-sai submodule pointer.
- How to verify it
Run full regression tests on Mellanox platforms
Signed-off-by: Dror Prital <drorp@nvidia.com>
New features and fixes in the new SDK/FW:
SN4600C | AN/LT support
SN2700 | AN/LT bugs fixes
WJH | FID_MISS support
Signed-off-by: Kebo Liu <kebol@nvidia.com>
- Why I did it
Add missed files for dynamic buffer calculation for ACS-MSN3420 and ACS-MSN4410
- How I did it
asic_table.j2: Add mapping from platform to ASIC
Add buffer_dynamic.json.j2 for ACS-MSN4410.
- How to verify it
Check whether the dynamic buffer calculation daemon starts successfully.
Signed-off-by: Stephen Sun <stephens@nvidia.com>
- Why I did it
There was a change to replace platform utils with sonic platform API in psuutil. However, psu API is not initialized on host side. The PR is to fix it.
Backport of #7016 to the 202012 branch.
- How I did it
Initialize PSU API on both host and non-host side
- How to verify it
Manual test
Integrate hw-management package V.7.0010.2002
Bug fixes:
Removing critical thermal zones to prevent unexpected software system shutdown:
*Kernel 4.9 -0071-mlxsw-core-Remove-critical-trip-point-from-thermal-z.patch
*Kernel 4.19 -076-mlxsw-core-Remove-critical-trip-point-from-thermal-z.patch
Removing redundant link for cpld3 for fixed systems (SN2100, SN2010).
Fix an issue with missed attribute for cpld3 (port CPLD) for SN2700, SN2410.
Signed-off-by: Stephen Sun <stephens@nvidia.com>
Fix the following issues:
Spectrum-2, Spectrum-3 | Port | Fix link issue when using 25 GbE rate between two ports while one is on Spectrum-2-based system and the other is on Spectrum-3-based system
All | warmboot | fail to upgrade from earlier SONiC versions with official SDK/FW 4.4.2306 (was on SONiC 201911)
All | What-Just-Happened | When enabling or disabling WJH under high traffic load to the host CPU, in very specific and low probability conditions, an error could occur, that may result in loss of data, channel failure or in extreme cases SW failure
Signed-off-by: Volodymyr Samotiy <volodymyrs@nvidia.com>
- Why I did it
The existing Fan led and Psu led object initialize itself to green color in init method. However, there are multiple daemons calls sonic platform API and there could be a case that:
A PSU is removed from system
Reboot switch
psud detects that 1 PSU is missing and set PSU led to red
Other daemon just start up and call sonic platform API, the API set PSU led to green by call PsuLed.init
This PR is a partial fix for the issue. As we also need guarantee that the led is initialized with a correct value. I checked existing psud and thermalctld code. psud always initialize the PSU led color on boot up, thermalcltd need some changes to initialize led color on the first run
- How I did it
Remove the led color initialization code from FanLed.init and PsuLed.init
- How to verify it
Manual test
- Why I did it
To pick up new features and fix from SDK/FW and SAI
SDK/FW new Feature:
All | Added support for multiple modules and cable types. For full list contact Nvidia networking support
Spectrum-3 | SN46000C | Added support for up to 5W on ports 49 to 64 .
SDK/FW bugs' fix:
All | fast reboot | fast boot failure from latest 201811 to 201911 and above
Spectrum | 10GbE/1GbE Transceiver (FTLX8574D3BCV) stopped working after firmware upgrade
Spectrum-2 | When device is rebooted with locked Optical Transceivers in split mode, the firmware may get stuck
Spectrum-2 | SN3700 | When connecting at 200GbE to Ixia K400, Ixia receives CRC errors
Spectrum-2 | SN3800 | On rare occasions packets loss may be experienced due to signal integrity issues
Spectrum-2 | When the port is a member of a LAG, after a warmboot and port toggle on the peer-side, the port remains down
Spectrum-3 | SN4700 | While using Optic cable in Split 4x1 mode in PAM4, when two first ports are toggled, the other 2 ports go down
Spectrum-3 | SN4700 | When working in 400GbE, deleting the headroom configuration (changing buffer size to zero) on the fly may cause continual packet drops
SAI
All | sFlow | Use hardcoded value 1 as netlink group number ax expected by hsflowd
- How I did it
Update the related version number in the make files and update the submodule pointer accordingly.
- How to verify it
Run regression test and everything works good.
To have the following fixes:
* All | Port status remains down after warm boot and flapping the port on peer side
* All | LAG HASH | IPv6 SRC_IP is not accounted in LAG hashing [
* All | ASIC driver | Kernel crash observed when driver reload is initiated before it fully loaded
* Spectrum-3 | Buffer | In lossless configuration, headroom is been evicted only when the shared buffers is free
* All | prevent FW access during ISSU
Signed-off-by: Volodymyr Samotiy <volodymyrs@nvidia.com>
- Why I did it
Update MFT tool version to 4.16.0
Bugs fixes:
mlxlink: Fixed an issue that caused the margin scan to fail with the following message: Eye scan not completed.
mlxcable: Cable firmware burning capability is not supported.
New features:
mlxlink: Enabled margin scan on Network links.
mlxlink: Added PRBS TX/RX polarity inversion using the following flags: --invert_tx_polarity / --invert_rx_polarity
- How I did it
Update MFT make file with new version number.
- How to verify it
Build image and test related functions on Mellanox platform
- Why I did it
Add support for new 64x200G SN4600 systems
- How I did it
Add all relevant files (w/o platform.json and hwsku.json as they will come later) with default SKU.
- How to verify it
Install image on switch, verify all ports are up and configured properly, run full platform SONiC tests.
In preparation for the merging of Azure/sonic-platform-common#173, which properly defines class and instance members in the Platform API base classes.
It is proper object-oriented methodology to call the base class initializer, even if it is only the default initializer. This also future-proofs the potential addition of custom initializers in the base classes down the road.
- Why I did it
System is stuck on 'starting' state on SimX platform because of infinite loop on 'hw-management-ready.sh' script .
The loop is polling to check if the hw-mgmt sysfs created before proceeding with the flow, for SimX platform the sysfs will never create so the system is not starting properly.
- How I did it
Add a condition to poll on hw-mgmt sysfs only if the switch is real HW and not SimX platform.
- How to verify it
Check "systemctl status hw-management.service" output on a SimX switch with this patch, the state will be "active".
Signed-off-by: Shlomi Bitton <shlomibi@nvidia.com>
- Why I did it
Mellanox SDK APIs support python 2 at the moment.
- How I did it
Mellanox SDK APIs support python 2 at the moment.
- How to verify it
Add python 2 to Mellanox syncd only.
- Which release branch to backport (provide reason below if selected)
docker exec -t syncd /bin/bash -c "sx_api_dbg_generate_dump.py /home/sx_api_dbg_dump"
You can see that it will work and generate /home/sx_api_dbg_dump
Signed-off-by: allas <allas@nvidia.com>
- Why I did it
Bug fixes
- In rare cases when thermal algorithm is reactivated after FAN/PSU insertion, FAN remains at high rpm
- When stop hw-management code received error in the log instead of exit code '0'.
- In SPC1 i2c sometimes collide with chip reset coming from SDK
- Remove raw eeprom data link, when working with PSU which don't have eeprom for "msn274x", "msn24xx" and "msn27xx" systems
- Fix memory leak on mlxsw_core_bus_device module removal
- How I did it
Update the hw-mgmt version number in the make file
Update the hw-mgmt repo pointer
- How to verify it
run platform related test cases on all Mellanox platform
Signed-off-by: Kebo Liu <kebol@nvidia.com>
Open ACL Outer VLAN ID for egress for ports part of VLAN RIF
- Why I did it
Open ACL Outer VLAN ID for egress for ports part of VLAN RIF
- How I did it
Updated SAI submodule pointer
- How to verify it
Build an image, deploy and check all is up and running.
Verify ACL sonic-mgmt test is passing
Signed-off-by: Volodymyr Samotiy <volodymyrs@nvidia.com>
Submodule commits included:
* src/sonic-platform-common 6ad0004...bd4dc03 (1):
> [sonic_sfp/qsfp_dd.py] Update DOM capability method name to align with other drivers (#163)
Also align all calling function names to match.
When Building syncd-rpc, libthrift has dependency on libboost-atomic1.71.0,
however the debian packager install version 1.67 instead. This PR
preinstalls libboost-atomic v 1.71 to avoid falling back to v 1.67.
signed-off-by: Tamer Ahmed <tamer.ahmed@microsoft.com>
**- Why I did it**
After migrating to python3, the operator '/' always get a float result, but it gets integer result in python2. Need fix this in thermal_conditions.
**- How I did it**
1. cast float value to int
2. change the unit test case to cover this situation
**- How to verify it**
Manually test and regression test
- Apply device MAC on port host interface when port is removed from LAG.
- [Shared Headroom]: fixed watermark handling for SHP flow
- Decrease verbosity of policer unbind message when no policer is attached
Signed-off-by: Stepan Blyschak <stepanb@nvidia.com>
**- Why I did it**
PR https://github.com/Azure/sonic-platform-common/pull/102 modified the name of the SFF-8436 (QSFP) method to align the method name between all drivers, renaming it from `parse_qsfp_dom_capability` to `parse_dom_capability`. Once the submodule was updated, the callers using the old nomenclature broke. This PR updates all callers to use the new naming convention.
**- How I did it**
Update the name of the function globally for all calls into the SFF-8436 driver.
Note that the QSFP-DD driver still uses the old nomenclature and should be modified similarly. I will open a PR to handle this separately.
**- Why I did it**
Reduce the time it takes for the ASIC FW burn as part of the automatic FW upgrade procedure.
**- How I did it**
Add -d option to mlxfwmanager tool to use the faster MST device and not the default one which is not the fastest one.
**- How to verify it**
I manually changed ASIC FW followed by reboot command in order for FW upgrade to take place on deinit.
I manually changed ASIC FW followed by hard reset in order for FW upgrade to take place on init.
Signed-off-by: liora <liora@nvidia.com>
**Why I did it**
Disable SDK extended dump due to issue found
**How I did it**
Update SAI submodule
**How to verify it**
Verify the SDK extended dump is not called.
Signed-off-by: Eran Dahan <erand@nvidia.com>
- Why I did it
Fix issue: ptf_nn_agent isn't able to start in syncd-rpc docker on buster.
- How I did it
The issue is fixed by installing python-dev, cffi and nnpy for python 2 explicitly.
- How to verify it
Run copp test on RPC image.
- Why I did it
Initially, we used Monit to monitor critical processes in each container. If one of critical processes was not running
or crashed due to some reasons, then Monit will write an alerting message into syslog periodically. If we add a new process
in a container, the corresponding Monti configuration file will also need to update. It is a little hard for maintenance.
Currently we employed event listener of Supervisod to do this monitoring. Since processes in each container are managed by
Supervisord, we can only focus on the logic of monitoring.
- How I did it
We borrowed the event listener of Supervisord to monitor critical processes in containers. The event listener will take
following steps if it was notified one of critical processes exited unexpectedly:
The event listener will first check whether the auto-restart mechanism was enabled for this container or not. If auto-restart mechanism was enabled, event listener will kill the Supervisord process, which should cause the container to exit and subsequently get restarted.
If auto-restart mechanism was not enabled for this contianer, the event listener will enter a loop which will first sleep 1 minute and then check whether the process is running. If yes, the event listener exits. If no, an alerting message will be written into syslog.
- How to verify it
First, we need checked whether the auto-restart mechanism of a container was enabled or not by running the command show feature status. If enabled, one critical process should be selected and killed manually, then we need check whether the container will be restarted or not.
Second, we can disable the auto-restart mechanism if it was enabled at step 1 by running the commnad sudo config feature autorestart <container_name> disabled. Then one critical process should be selected and killed. After that, we will see the alerting message which will appear in the syslog every 1 minute.
- Which release branch to backport (provide reason below if selected)
201811
201911
[x ] 202006
Changes in the new release:
1. Policy based hashing optimization
2. New attribute support for Max port headroom
3. Tunnel ECN map fixes
4. Tunnel EVPN skeleton extensions (peer attrib, maps)
5. Bridge port admin not affecting port admin (optimize port down time)
6. CRM new API for neighbors and tunnel termination entries
7. Improve FDB event for flush by bridge port (before, null bridge was reported to SONiC, now the bridge will be extracted from bridge port)
8. DHCP L2 v4+v6 traps (for ZTP use case)
9. Generic counter implementation
Signed-off-by: Kebo Liu <kebol@nvidia.com>
- combine docker-ptf-saithrift into docker-ptf docker
- build docker-ptf under platform vs
- remove docker-ptf for other platforms
Signed-off-by: Guohan Lu <lguohan@gmail.com>