Why I did it
Command "sudo sfputil show error-status -hw" shows "OK (Not implemented)" in the output.
How I did it
Add a new SFP API get_error_description support in Nokia sonic-platform sfp.py module.
How to verify it
Run the new image and execute command "sudo sfputil show error-status -hw"
Co-authored-by: Pavan-Nokia <120486223+Pavan-Nokia@users.noreply.github.com>
Why I did it
High CPU utilization by entropy.py
How I did it
Remove entropy script as it does not work anymore and is no longer needed for bullseye(202205).
In Buster(202012) the max available poolsize (entropy_avail) for entropy is 4096 and our entropy.py script was based on this value. With the change in kernel to bullseye on 202205 this entropy poolsize was changed to 256 which also causes our script to fail.
This script was initially added to provide SW assistance to improve the system entropy value available early on in the Sonic boot sequence on buster.
On bullseye (Linux kernel 5.10) this is no longer needed as this feature has been improved.
How to verify it
run "top" command to check CPU usage.
Co-authored-by: Pavan-Nokia <120486223+Pavan-Nokia@users.noreply.github.com>
- Why I did it
Added platform specific script to be invoked during SAI failure dump. Added some generic changes to mount /var/log/sai_failure_dump as read write in the syncd docker
- How I did it
Added script in docker-syncd of mellanox and copied it to /usr/bin
- How to verify it
Manual UT and new sonic-mgmt tests
Co-authored-by: Sudharsan Dhamal Gopalarathnam <dgsudharsan@users.noreply.github.com>
* Enable marvell-armhf saiserver docker
Signed-off-by: zitingguo-ms <zitingguo@microsoft.com>
* fix libsaithriift build env
Signed-off-by: zitingguo-ms <zitingguo@microsoft.com>
* fix thrift 014 dependent issue in armhf
* fix build env
Signed-off-by: zitingguo-ms <zitingguo@microsoft.com>
* [sai_ptf]fix thrift armhf build
in armhf buidl failed as no python command
how
add a checker for different python command, python/python3 and base on result use the right command
verify
container build
* [Thrift_014[armhf]]Fix libboost_unit_test_framework.a not found during build
Why
error happen build thirft in armhf
How
fix this issue, add a soft link for the dependent file
Verify
Build pipeline
Signed-off-by: richardyu-ms <richard.yu@microsoft.com>
* add metadata dependence
Signed-off-by: zitingguo-ms <zitingguo@microsoft.com>
* change build pipeline
Signed-off-by: zitingguo-ms <zitingguo@microsoft.com>
---------
Signed-off-by: zitingguo-ms <zitingguo@microsoft.com>
Signed-off-by: richardyu-ms <richard.yu@microsoft.com>
Co-authored-by: richardyu-ms <richard.yu@microsoft.com>
Why I did it
To pick up the below DNX fixes:
CS00012275689: DSCP->TC and TC->QUEUE mappings are not happening for packets received on LAG ports (SONIC-69367)
CS00012277618: Crash in _brcm_sai_dnx_irpp_port_core_get (SONIC-70001)
How I did it
Updated SAI branch with the above fixes
How to verify it
Ran basic sonic-mgmt tests with the SAI debian on XGS and DNX platforms
Why I did it
[Seastone] Enhancement fix for PR12200 syseeprom issue.
How I did it
Enhance the fix through replace the hardcoded devnum to bash variable
How to verify it
show platform syseeprom or decode-syseeprom
Co-authored-by: Ikki Zhu <79439153+qnos@users.noreply.github.com>
add module reboot APIs for chassis
add supervisor module on linecard (fixes show chassis module midplane-status)
improve RTC update mechanism and sync every 10 mins
fix sbtsi temp sensor presence/thresholds
fix Mineral status leds
remove thermal object on xcvrs
misc fixes
- Why I did it
To include latest fixes and new functionality
SAI
1. Temporary WA for query enum capabilities for tunnel peer mode, to not return P2P
2. sai debug dump returns while last extra dump is running
3. open inner SRC and DST IP for ECMP / LAG general hash objects
4. tunnel peer mode returns hard coded
5. tunnel decap dscp mode
6. support default tunnel src ip
7. failure to add a port to a LAG in VLANs configured with flood_ctrl
8. Add P2P peer mode for IP in IP tunnels
9. Add per port IP counters
10. Clean up VXLAN srcport static (XML) functionality, as only dynamic (API) is in use
11. Fix enum capabilities of native hash fields
12. sai_acl_db_group_ptr usage
13. Clean QoS config of the LAG when all members was removed (bug
SDK/FW
1. Fixed bug in recovery mechanism in case of I2C error when trying to access the XSFP module.
2. On the NVIDIA Spectrum-2 switch, when receiving a packet with Symbol Errors on ports that are configured to cut-thought mode, a pipeline might get stuck.
3. On the Spectrum-2 and Spectrum-3 switch, if you enable ECN marking and the port is in split mode, traffic sent to the port under congestion (for example, when connecting two ports with a total speed of 50GbE to a single 25GbE port) is not marked.
4. Modifying existing entry/Adding new one when switch is at its maximum capacity (full by maximum allowed entries from any type such as routes, FDB, and so forth), will fail with an error.
5. When many ports are active (e.g., 70 ports up), and the configuration of shared buffer is applied on the fly, occasionally, the firmware might get stuck.
6. When a system has more than 256 ACL rules, on rare occasion, removing/adding rules may cause some ACL rules not to work.
7. On SN2201 system, on RJ45 port, the link might appear in 'down' state even if it operations properly.
8. Layer 4 port information is not initialized for BFD packet event. To address the issue, remote peer UDP port information was added in BFD packet event.
9. When setting LAG as a SPAN analyzer, the distributor mode of the LAG members was not taken into account. It may happen that the LAG member with distributor mode disabled will be set as a SPAN analyzer port.
- How I did it
Updated SDK/SAI submodule and relevant makefiles with the required versions.
- How to verify it
Build an image and run tests from "sonic-mgmt".
Signed-off-by: Volodymyr Samotiy <volodymyrs@nvidia.com>
Why I did it
To bring in the following fixes:
Revert temporary fix added to disable SA equal DA drops
CS00012273013 - [7.1][J2, J2c+] Disable SA Equals DA trap on DNX
CS00012274222 - How to block the voq for given destination port for a flow from a remote mod-id
CS00012275381 - SAI_INGRESS_PRIORITY_GROUP_STAT_PACKETS is incremented for port's PG's even if there are no traffic sent to that PG
CS00012274433 - Local Fault and Remote Fault are not polled by linkscan thread
How I did it
Merged above fixes to SAI code
How to verify it
Validated by running the basic sanity tests on XGS and DNX chassis platforms including
fib/test_fib.py
decap/test_decap.py
drop_counters/test_drop_counters.py
arp/test_arpall.py
- Why I did it
To include latest fixes and new functionality
* SAI
1. Temporary WA for query enum capabilities for tunnel peer mode, to not return P2P
2. sai debug dump returns while last extra dump is running
3. open inner SRC and DST IP for ECMP / LAG general hash objects
4. tunnel peer mode returns hard coded
5. tunnel decap dscp mode
6. support default tunnel src ip
7. failure to add a port to a LAG in VLANs configured with flood_ctrl
8. Add P2P peer mode for IP in IP tunnels
9. Add per port IP counters
10. Clean up VXLAN srcport static (XML) functionality, as only dynamic (API) is in use
11. Fix enum capabilities of native hash fields
12. sai_acl_db_group_ptr usage
13. Clean QoS config of the LAG when all members was removed (bug
* SDK/FW
1. Fixed bug in recovery mechanism in case of I2C error when trying to access the XSFP module.
2. On the NVIDIA Spectrum-2 switch, when receiving a packet with Symbol Errors on ports that are configured to cut-thought mode, a pipeline might get stuck.
3. On the Spectrum-2 and Spectrum-3 switch, if you enable ECN marking and the port is in split mode, traffic sent to the port under congestion (for example, when connecting two ports with a total speed of 50GbE to a single 25GbE port) is not marked.
5. Modifying existing entry/Adding new one when switch is at its maximum capacity (full by maximum allowed entries from any type such as routes, FDB, and so forth), will fail with an error.
6. When many ports are active (e.g., 70 ports up), and the configuration of shared buffer is applied on the fly, occasionally, the firmware might get stuck.
7. When a system has more than 256 ACL rules, on rare occasion, removing/adding rules may cause some ACL rules not to work.
8. On SN2201 system, on RJ45 port, the link might appear in 'down' state even if it operations properly.
9. Layer 4 port information is not initialized for BFD packet event. To address the issue, remote peer UDP port information was added in BFD packet event.
10. When setting LAG as a SPAN analyzer, the distributor mode of the LAG members was not taken into account. It may happen that the LAG member with distributor mode disabled will be set as a SPAN analyzer port.
- How I did it
Updated SDK/SAI submodule and relevant makefiles with the required versions.
- How to verify it
Build an image and run tests from "sonic-mgmt".
Signed-off-by: Volodymyr Samotiy <volodymyrs@nvidia.com>
Why I did it
why
In order to apply different config across different platform, and use the code with a unified format, reuse syncd init script to init saiserver.
How I did it
how
Reuse syncd init script
How to verify it
Test
Test in DUT s6000 and dx010 with sonic 202205
Why I did it
Advance SAI Redis head pointer
How I did it
changes:
sonic-net/sonic-sairedis@cf679e7sonic-net/sonic-sairedis@8d6688e
[202205][Submodule][SAI]Advance SAI head pointer sonic-sairedis#1185 sonic-net/sonic-sairedis@66f2961
remove parameter --skip_error, which removed from [202205][Submodule][SAI]Advance SAI head pointer sonic-sairedis#1185
How to verify it
local image build
This PR is to backport #13100 to the 202205 branch since can not be cleanly cherry-picked.
Following code to judge whether a process is running inside a docker could get stuck on the simx platform
subprocess.Popen(["docker", "--version"],
stdout=subprocess.PIPE,
stderr=subprocess.STDOUT,
universal_newlines=True)
When it gets stuck, the config-chassisdb service can not be successfully started, thus the system can not be booted up.
root@sonic:/# service config-chassisdb status
config-chassisdb.service - Config chassis_db
Loaded: loaded (/lib/systemd/system/config-chassisdb.service; enabled; vendor preset: enabled)
Active: activating (start) since Thu 2022-12-15 09:23:02 UTC; 29min ago
Main PID: 571 (config-chassisd)
Tasks: 14 (limit: 9501)
Memory: 132.4M
CGroup: /system.slice/config-chassisdb.service
├─571 /bin/bash /usr/bin/config-chassisdb
├─575 /usr/bin/python3 /usr/local/bin/sonic-cfggen -H -v DEVICE_METADATA.localhost.platform
├─602 /bin/sh -c sudo decode-syseeprom -m
├─603 sudo decode-syseeprom -m
├─607 /usr/bin/python3 /usr/local/bin/decode-syseeprom -m
├─616 /bin/sh -c docker --version 2>/dev/null
└─617 docker --version
- How I did it
Use an alternative way to implement this function and issue can be avoided:
docker_env_file = '/.dockerenv'
return os.path.exists(docker_env_file) is False
- How to verify it
run regression on real hardware and simx platform.
Why I did it
In order to prevent the sonic-mgmt/tests/platform_tests/sfp/test_sfputil.py test failing on the log analyzer step.
The mentioned test is performing the sfputil reset EthernetX for every interface on the SONiC switch, this action will flap the SFP device status (INSTERTED -> REMOVED -> INSTERTED).
The SONiC XCVRD daemon will catch this SFP device status change (because it is monitoring the presence status of the cable).
To judge the cable presence status, currently, we are still leveraging to read the first bytes of the EEPROM, and the EEPROM could be not ready at some moment and the SONiC XCVRD daemon will print the error log to Syslog:
ERR pmon#xcvrd: Error! Unable to read data for 'xx' port, page 'xx' offset 128, rc = 1, err msg: Sending access register
How I did it
Change logging severity from ERR to WARNING
Signed-off-by: Vadym Hlushko <vadymh@nvidia.com>
Why I did it
To bring the following fixes:
Applied customer patch for limited port breakout support in rel_ocp_sai_7_1.
Revert "Merged PR 7224850: SAI7.1_DNX: Temp workaround for Nexthop Group Scale Issue(CS00012251649)".
backport SONIC-67662 to SAI7.1:JR2C ECMP partition for NHgroup members.
How I did it
Updated SAI code with the fixes above.
How to verify it
Run the SONiC and SAI test with the SAI pipeline.
Why I did it
Update Marvell armhf sai debian version. Includes supports for,
Autoneg
Everflow
How to verify it
Compile and load SONiC armhf bin
Signed-off-by: rajkumar38 <rpennadamram@marvell.com>
Why I did it
smartctl tool is available only in PMON docker. Hence, the tool may be not accessible incase PMON docker goes down.
Using iSMART_64 tool to fetch the SSD firmware version and device model information.
How I did it
Replacing smartctl with iSMART_64.
1d53bf4 Skip platform NDK health check two times in watchdog.sh
d68297c Added code to shutdown the channel after the grpc call also fixed the show fp-status command
0769efe Impelemented the module API to return the correct eeprom info for fabric card.
171569c Remove explicit logger identifier for transceiver module operations; use inherited id
6c4d651 Corrected the log messages for firmware install
Signed-off-by: mlok <marty.lok@nokia.com>
Why I did it
enable sai-ptf logger in sai_adapter to log all the sai api invcations
How I did it
add build parameter to enable the sai-ptf logger when build sai PRC
How to verify it
local build test
test the generated sai_adapter
test with pipeline
Signed-off-by: richardyu-ms <richard.yu@microsoft.com>
Why I did it
Move armhf syncd docker compilation to bullseye.
How I did it
compile syncd docker for armhf platform using below commands,
NOJESSIE=1 NOSTRETCH=1 NOBUSTER=1 BLDENV=bullseye make configure PLATFORM=marvell-armhf PLATFORM_ARCH=armhf
NOJESSIE=1 NOSTRETCH=1 NOBUSTER=1 BLDENV=bullseye make target/docker-syncd-mrvl.gz
How to verify it
upgrade the syncd docker and verify ports are up.
Signed-off-by: rajkumar38 <rpennadamram@marvell.com>
cherry-pick #12761
Make syncd rpc docker which supports sai-ptf v2
Part of previous PR #11610
local bulild the target
NOSTRETCH=y NOJESSIE=y make configure PLATFORM=broadcom NOSTRETCH=y NOJESSIE=y ENABLE_SYNCD_RPC=y SAITHRIFT_V2=y make target/docker-syncd-brcm-rpcv2.gz NOSTRETCH=y NOJESSIE=y ENABLE_SYNCD_RPC=y SAITHRIFT_V2=y make target/docker-saiserverv2-brcm.gz
Signed-off-by: richardyu-ms <richard.yu@microsoft.com>
Signed-off-by: richardyu-ms <richard.yu@microsoft.com>
add partial reboot cause support for linecards
add watchdog support for linecards
add power draw information for chassis
properly implement Chassis.get_port_or_cage_type
fix pcieutil on chassis with powered off cards
fix watchdog-control.service crash
misc fixes and cleanups
* Build docker-gbsyncd-broncos image
* Correct typo in LIBSAI_BRONCOS_URL_PREFIX
* Update docker-gbsyncd-broncos/Dockerfile.j2
* Enable debug shell support on docker-gbsyncd-broncos
* Include bcmsh in docker-gbsyncd-broncos
Why I did it
In docker-gbsyncd-broncos image, enable debug shell support for BRCM broncos PHY.
How I did it
How to verify it
Note: need enable attr SAI_SWITCH_ATTR_SWITCH_SHELL_ENABLE support in BCM PAI library
# bcmsh
Press Enter to show prompt.
Press Ctrl+C to exit.
NOTICE: Only one bcmsh or bcmcmd can connect to the shell at same time.
BRCM:> help
help
List of available commands
- h or help => Print command menu
- l => Print list of active ports on the PHY
- ps <port_id> <options> => Print port status
<options> => 1 -> Link status
=> 2 -> Link training failure status
=> 3 -> Link training RX status
=> 4 -> PRBS lock status
=> 5 -> PRBS lock loss status
- rd <port_id> <addr> <no of registers to read> => Read register contents
- wr <port_id> <addr> <data> => Write register data
- rrd <lanemap> <if_side> <addr> <no of registers to read> => Raw read register contents using lanemap and if_side (line = 0, system = 1)
- rwr <lanemap> <if_side> <addr> <data> => Raw write register data using lanemap and if_side (line = 0, system = 1)
- fw or firmware => Print firmware version of the PHY
- pd or port_dump <port_id> <flags> => Dump port status
- eyescan <port_id> => Display eye scan
- fec_status <port_id> => Get fec status of the port
- polarity <lanemap> <if_side> <TX polarity> <RX Polarity> => Set TX and RX polarity
<lanemap> => 0xF, 0xFF, or 0xFFFF based on number of lanes
<if_side > => Line = 0, System = 1
<TX/RX Polarity> =>_TX/RX Polarity bitmap of all lanes
Each bit represents a lane number.
E.g. Lane 0's polarity value (0 or 1) is populated in Bit 0.
- polarity <lanemap> <if_side> => Print TX and RX polarity
- lb <port_id> <lb_value> => Enable loopback on the port
lb_value = 0 -> Disable, 1 -> PHY, 2 -> MAC
- lb <port_id> => Print loopback configuration of the port
- prbs <port_id> <options> <val> => Set/Get PRBS configuration
<options> => 1 -> Get PRBS state and polynomial
2 -> Set PRBS Polynomial, <val> - PRBS Polynomial
Please refer to phy/chip documentation for valid values
3 -> Enable PRBS
<val> => 0 Disable PRBS
1 Enable both PRBS Transmitter and Receiver
2 Enable PRBS Receiver
3 Enable PRBS Transmitter
exit or q => Exit the diagnostic shell
- Why I did it
Update SN2201 dynamic minimum fan speed table according to data provided by the thermal team.
- How I did it
Update the thermal table in device_data.py
- How to verify it
Run platform related regression
Signed-off-by: Kebo Liu <kebol@nvidia.com>
- Why I did it
Update SDK/FW version - 4.5.3186/2010_3186 in order to have the following changes:
New functionality:
1. Added support for 6.5W (Class 8) in ports 49-50, 53-54, 57-58, and 61-62 on SN4600 system
Fix the following issues:
1. On very rare occasion (~1/100K), during I2C transaction with MMS1V50-WM and MMS1V90-WR modules on SN4700 system, the module may send unexpected stop which violate the I2C specification, possibly affecting the link up flow
2. When running 1GbE speeds on SN4600 system, the port remained active while peer side was closed
3. While toggling the cable with ‘sfputil lpmode on/off’, error msg like “ERR pmon#xcvrd: Receive PMPE error event on module 1: status {X} error type {y}” could be received
4. When toggling many ports of the Spectrum devices while raising 10GbE link up and link maintenance is enabled, the switch may get stuck and may need to be rebooted
5. When trying to reconfigure the Flex Parser header and Flex transition parameters after ISSU, the switch will returned an error even if the configuration was identical to that done before performing the ISSU
6. While moving from lossless to lossy mode while shared headroom was used, reduction of the shared headroom can only be done prior to pool type change and when shared headroom is not utilized
7. SLL configuration is missing in SDK dump
8. If TTL_CMD_COPY is used in Encap direction for a packet with no TTL, then the value passed in the ttl data structure will be used if non-zero (default 255 if zero)
9. PCI calibration changes from a static to a dynamic mechanism
10. Layer 4 port information is not initialized for BFD packet event. To address the issue, remote peer UDP port information was added in BFD packet event
11. SDK returned error when FEC mode is set on twisted pair, when FEC was set to None
- How I did it
Update pointer for the SDK/FW
- How to verify it
Run regression tests
Signed-off-by: dprital <drorp@nvidia.com>
Why I did it
Change the path of sonic submodules that point to "Azure" to point to "sonic-net"
How I did it
Replace "Azure" with "sonic-net" on all relevant paths of sonic submodules