This piece of information is currently not used. Revert this
pull request in the future to add back the default mirror
session information into the configuration database.
Signed-off-by: Shu0T1an ChenG <shuche@microsoft.com>
[build_debian] Generate checksum of ASIC config files
* Adds script to generate checksums for ASIC config files
* Adds step to build_debian that copies ASIC config checksum into SONiC filesystem
Signed-off-by: Danny Allen daall@microsoft.com
Submodule src/sonic-utilities 4f72e14..11b4cf1:
> [fast-reboot] Check if ASIC config has changed before warm reboot (#621)
> [neighbor_advertiser]: Change the ICMPv6 type to 135 (#629)
> [acl_loader]: Fix show mirror_session error (#580)
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
There is a very low possibility that qsfp_status exists when opening it but doesn't when reading it a bit later. If this occurs an exception is raised.
However, this should be treated as "not presence" rather than causing an exception, which can be achieved by putting it into try block.
Fixed errors in the following files to resolve build failures
- docker-ptf-nephos.mk\docker-syncd-nephos.mk\libsaithrift-dev.mk\rules.mk
- Upgrade sai.mk for support sai_1.4.1 and upgrade sdk version to 3.0.0
radv should be left alone during warm restart of swss. Otherwise it will
announce departure and cause hosts to lose default gateway.
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
ndisc6 gathers a few diagnostic tools for IPv6 networks including:
- ndisc6, which performs ICMPv6 Neighbor Discovery in userland,
- rdisc6, which performs ICMPv6 Router Discovery in userland,
- rltraceroute6, a UDP/ICMP IPv6 implementation of traceroute,
- tcptraceroute6, a TCP/IPv6-based traceroute implementation,
- tcpspray6, a TCP/IP Discard/Echo bandwidth meter,
- addrinfo, easy script interface for hostname and address resolution,
- dnssort, DNS sorting script.
Signed-off-by: Guohan Lu <gulv@microsoft.com>
- Improve smbus reliability for all platforms
- Delay processing of the reboot cause to reduce critical path
- Add support of get_change_event for PSUs
* fix sfpd initialize issue
* fix review comments
* rephrase the output log
* fix retry counter
* change the retry time to 10, means set max waiting time 1024s
* fix mlnx-sfpd init flow with new solution
* [mlnx-sfpd] address comments
1. wait for 5 seconds * 30 times, 150 seconds totally. use constant wait time for each retry.
2. use try/except structure so that error can be handled in a graceful way
* [mlnx-sfpd] wait 5 seconds after SDK_DAEMON_READY_FILE exists to make sure SDK is fully up.
* [mlnx-sfpd]simplify initialization by using deinitialize on initializing failure
Present: Servers are listed in the same order as in redis-db
Fix: Save the sort o/p, hence use sorted list to write into pam.d's conf.
As well convert priority to integer for use by sort.
Submodule src/sonic-sairedis 54c8e78..992cdc0:
> Do not store invalid OIDs from FDB notification into ASIC DB (#503)
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
* [service dependent] describe non-warm-reboot dependency outside systemctl
When dependency was described with systemctl, it will kick in all the time,
including under warm reboot/restart scenarios. This is not what we always
want. For components that are capable of warm reboot/start, they need to
describe dependency in service files.
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
* [service] teamd service should not require swss service
Adding require swss will cause teamd to be killed by systemctl when swss
stops. This is not what we want in warm reboot.
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
* refactoring code
* rename functions to match other functions in the file
when device disk is small, do not unzip dockerfs.tar.gz on disk.
keep the tar file on the disk, unzip to tmpfs in the initrd phase.
enabled this for 7050-qx32
Signed-off-by: Guohan Lu <gulv@microsoft.com>
* [Mellanox/mlnx-platform-api] enable mellanox's platform-api to be loaded as a whole.
* [chassis] update reboot-cause handling code to adapt the hw-management currently running on 201811
* [chassis]handle the case that reboot cause file can be any dir matching pattern "hwmonX".
The race condition could happen like this:
When an interface is enslaved into the port channel immediately after
it is created, the order of creating the ifinfo and linking the ifinfo to
the port is not guaranteed.
Please check the patch commit message to get full details.
Signed-off-by: Shu0T1an ChenG <shuche@microsoft.com>
* [warm reboot] save configuration after warm reboot
After warm reboot, save a copy of in memory database to config_db.json,
upgrade procedure might have removed config_db.json to force new image
to reload minigraph. However, reload minigraph is skipped during warm
reboot. Missing config_db.json would cause device to fault in next
non-upgrading cold/fast reboot.
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
* Update finalize-warmboot.sh