- Why I did it
Update hw-mgmt to a new version to pick up support for the SN4600C A1 system.
- How I did it
Update the pointer of the hw-mgmt submodule
Update the hw-mgmt version number
Remove the staled code patch to hw-mgmt userspace code.
- How to verify it
Run platform regression on Mellanox platforms.
Signed-off-by: Kebo Liu <kebol@nvidia.com>
- Why I did it
To have an ability to use PRM sniffer.
- How I did it
Enabled the option in configure flags.
- How to verify it
Built and ran on switch. Enabled the feature in runtime and checked the sniffer recording.
Signed-off-by: Stepan Blyschak <stepanb@nvidia.com>
Backport https://github.com/Azure/sonic-buildimage/pull/9259 to 202012
#### Why I did it
Nvidia platform API does not support set LED to orange.
#### How I did it
Allow user to set LED to orange
#### How to verify it
Manual test
Why I did it
Arista did not update db with eeprom info. Previous PR had issues that were reverted.
How I did it
Had Arista eeprom class inherit the class that has method to update db. Updated platform API methods for Arista 202012.
How to verify it
In redis-cli the keys and values can be seen. Can use sonic-mgmt testing to verify behavior, and see the chassis platform API methods have not regressed.
- Why I did it
Support zero buffer profiles
1. Add buffer profiles and pool definition for zero buffer profiles
2. Support applying zero profiles on INACTIVE PORTS
3. Enable dynamic buffer manager to load zero pools and profiles from a JSON file
- How I did it
Add buffer profiles and pool definition for zero buffer profiles
If the buffer model is static:
* Apply normal buffer profiles to admin-up ports
* Apply zero buffer profiles to admin-down ports
If the buffer model is dynamic:
* Apply normal buffer profiles to all ports
* buffer manager will take care when a port is shut down
Update buffers_config.j2 to support INACTIVE PORTS by extending the existing macros to generate the various buffer objects, including PGs, queues, ingress/egress profile lists
Originally, all the macros to generate the above buffer objects took active ports only as an argument.
Now that buffer items need to be generated on inactive ports as well, an extra argument representing the inactive ports need to be added.
To be backward compatible, a new series of macros are introduced to take both active and inactive ports as arguments
The original version (with active ports only) will be checked first. If it is not defined, then the extended version will be called.
Only vendors who support zero profiles need to change their buffer templates
Enable buffer manager to load zero pools and profiles from a JSON file:
The JSON file is provided on a per-platform basis
It is copied from platform/<vendor> folder to /usr/share/sonic/temlates folder in compiling time and rendered when the swss container is being created.
To make code clean and reduce redundant code, extract common macros from buffer_defaults_t{0,1}.j2 of all SKUs to two common files:
One in Mellanox-SN2700-D48C8 for single ingress pool mode
The other in ACS-MSN2700 for double ingress pool mode
Those files of all other SKUs will be symbol link to the above files
Update sonic-cfggen test accordingly:
* Adjust example output file of JSON template for unit test
* Add unit test in for Mellanox's new buffer templates.
- How to verify it
Regression test.
Unit test in sonic-cfggen
Run regression test and manually test.
Signed-off-by: stephens <stephens@nvidia.com>
- Why I did it
To include latest fixes.
1. On CMIS modules, after low power configuration, the firmware waited for the module state to be ModuleReady instead of ModuleLowPower causing delays.
2. When connecting Spectrum devices with optical transceivers that support RXLOS, remote side port down might cause the switch firmware to get stuck and cause unexpected switch behavior.
3. On rare occasions, when working with port rates of 1GbE or 10GbE and congestion occurs, packets may get stuck in the chip and may cause switch to hang.
4. When ECMP has high amount of next-hops based on VLAN interfaces, in some rare cases, packets will get a wrong VLAN tag and will be dropped.
5. Using SN4600C with copper or optics loopback cables in NRZ speeds, link may raise in long link up times ( up to 70 seconds).
6. When connecting SN4600C to SN4600C after Fastboot in 50GbE No_FEC mode with a copper cable, the link up time may take ~20 seconds.
- How I did it
Updated SDK submodule and relevant makefiles with the required versions.
- How to verify it
Build an image and run tests from "soni-mgmt".
Signed-off-by: Volodymyr Samotiy <volodymyrs@nvidia.com>
- Why I did it
This is to update the common sonic-buildimage infra for reclaiming buffer.
- How I did it
Render zero_profiles.j2 to zero_profiles.json for vendors that support reclaiming buffer
The zero profiles will be referenced in PR [Reclaim buffer] Reclaim unused buffers by applying zero buffer profiles #8768 on Mellanox platforms and there will be test cases to verify the behavior there.
Rendering is done here for passing azure pipeline.
Load zero_profiles.json when the dynamic buffer manager starts
Generate inactive port list to reclaim buffer
Signed-off-by: Stephen Sun <stephens@nvidia.com>
- Why I did it
When PSU is powered off, the PSU is still on the switch and the air flow is still the same. In this case, it is not necessary to set FAN speed to 100%.
- How I did it
When PSU is powered of, don't treat it as absent.
- How to verify it
Adjust existing unit test case
Add new case in sonic-mgmt
1. CS00012211718 [4.3] Pfcwd getting continuously triggered/restored when pause frames are sent continuously to both queues of a port (TD2/Th/Th2/TD3) MSFT Default
Preliminary tests look fine. BGP neighbors were all up with proper routes programmed
interfaces are all up
Manually ran the following test cases on 7050CX3 (TD3) T0 DUT and all passed:
```
fib/test_fib.py
vxlan/test_vxlan_decap.py
fdb/test_fdb.py
decap/test_decap.py
ipfwd/test_dip_sip.py
ipfwd/test_dir_bcast.py
acl/test_acl.py
vlan/test_vlan.py
platform_tests/test_reboot.py
```
This is to pick up BRCM SAI 4.3.5.1-7 fixes which contains the following fixes:
1. CS00012209390: SONIC-50037, Used SAI_SWITCH_ATTR_QOS_DSCP_TO_TC_MAP as a default decap map for IPinIP tunnels.
2. CS00012212995: SONIC-50948 SAI_API_QUEUE:_brcm_sai_cosq_stat_get:1353 egress Min limit get failed with error Invalid parameter
3. SONIC-51583: Fixed acl group member creation failure with priority of -1
4. CS00012215744:SONIC-51395 [TH, TH2] WB 3.5 to 4.3 fails at APPLY_VIEW while setting SAI_PORT_ATTR_EGRESS_ACL
5. SONIC-51638: SDK-249337 ERROR: AddressSanitizer: heap-buffer-overflow in _tlv_print_array
Preliminary tests look fine. BGP neighbors were all up with proper routes programmed
interfaces are all up
Manually ran the following test cases on 7050CX3 (TD3) T0 DUT and all passed:
```
fib/test_fib.py
vxlan/test_vxlan_decap.py
fdb/test_fdb.py
decap/test_decap.py
ipfwd/test_dip_sip.py
ipfwd/test_dir_bcast.py
acl/test_acl.py
vlan/test_vlan.py
platform_tests/test_reboot.py
```
This is to pick up BRCM SAI 4.3.5.1-6 fixes which contains the following fixes:
1. CS00012213351 SONIC-50679: [TH, TH2] Warm-reboot from 3.5 to 4.3 fails due to null objects discovered
2. CS00012182162: SONIC-49805 TD3 MMU config profile optimization changes
3. CS00012210826:SONIC-50205/760c60fc: Should read MMU_INTFI_MMU_PORT_TO_MMU_QUEUES_FC_BKP for TH3
Preliminary tests looks fine. BGP neighbors were all up with proper routes programmed
interfaces are all up
Manually ran the following test cases on 7050CX3 (TD3) T0 DUT and all passed:
```
fib/test_fib.py
vxlan/test_vxlan_decap.py
fdb/test_fdb.py
decap/test_decap.py
ipfwd/test_dip_sip.py
ipfwd/test_dir_bcast.py
acl/test_acl.py
vlan/test_vlan.py
platform_tests/test_reboot.py
```
* [Nokia ixs7215] Platform API fixes
This commit delivers the following fixes
- Fix bug preventing access to second PSU eeprom
- Fix bug preventing updates to front panel PSU status led
- Fix SFP reset test case failure
* Fix LGTM alert
Co-authored-by: Zhi Yuan (Carl) Zhao <zyzhao@arista.com>
Why I did it
The previous PR #8914 was reverted due to crashing the 202012 syseepromd.
How I did it
Tested the 202012 image with change and fixed the disparity between master and 202012.
How to verify it
Run the built image on the dut and syseepromd will not crash, and in redis-cli can fetch the eeprom information.
Why I did it
Sujin noticed that Arista eeprom platform API cannot update the redis database. Although Arista and Guohan believe that database update logic should be part of the daemon, it is easy enough to implement the fix for Arista for now.
How I did it
Made Arista eeprom platform API inherit from TlvInfoDecoder, then write Arista's own visit_eeprom method.
Co-authored-by: Zhi Yuan (Carl) Zhao <zyzhao@arista.com>
Why I did it
Vaibhav Dahiya notified me that invalid fan speed policy was expecting an error raised in sonic-mgmt testing, but it was not raised.
This change will fix test_platform_info.py::test_thermal_control_load_invalid_value_json
How I did it
Add in the suggested code chunk to Arista platform submodule to raise ValueError when an invalid fan speed is set in thermal policy.
How to verify it
Vaibhav Dahiya has verified it through sonic-mgmt testing.
Co-authored-by: Zhi Yuan (Carl) Zhao <zyzhao@arista.com>
- Why I did it
Change thermal recover threshold from temp_trip_norm to temp_trip_high, so that thermal algorithm would set fan speed to minimum allowed earlier and save power.
- How I did it
Change thermal recover threshold from temp_trip_norm to temp_trip_high
- How to verify it
Manual test
Why I did it
To monitor the SSD health condition in DellEMC S6100 platform post upgrade.
A daemon is introduced to monitor the SSD every one hour.
To check for SSD status at boot time and at the time of cold-reboot.
All these changes are supported only for newer SSD firmware.
Porting changes from 201911 branch
Added a platform_reboot_pre_check script to prevent cold-reboot based on SSD status.
Depends on Azure/sonic-utilities#1788
DO NOT MERGE UNTIL ABOVE PR IS MERGED
How I did it
On branch s6100_ssd_202012
Changes to be committed:
(use "git restore --staged ..." to unstage)
modified: platform/broadcom/sonic-platform-modules-dell/debian/platform-modules-s6100.install
new file: platform/broadcom/sonic-platform-modules-dell/s6100/scripts/iSMART_64
new file: platform/broadcom/sonic-platform-modules-dell/s6100/scripts/platform_reboot_pre_check
modified: platform/broadcom/sonic-platform-modules-dell/s6100/scripts/s6100_platform.sh
new file: platform/broadcom/sonic-platform-modules-dell/s6100/scripts/s6100_ssd_mon.sh
new file: platform/broadcom/sonic-platform-modules-dell/s6100/scripts/s6100_ssd_upgrade_status.sh
new file: platform/broadcom/sonic-platform-modules-dell/s6100/scripts/soft-reboot_plugin
new file: platform/broadcom/sonic-platform-modules-dell/s6100/systemd/s6100-ssd-monitor.service
new file: platform/broadcom/sonic-platform-modules-dell/s6100/systemd/s6100-ssd-monitor.timer
new file: platform/broadcom/sonic-platform-modules-dell/s6100/systemd/s6100-ssd-upgrade-status.service
* [Nokia ixs7215] Miscellaneous platform API fixes
This commit delivers the following fixes for the Nokia ixs7215 platform
- Fix bug in a fan API error path
- Add support for setting the fan drawer led
- Add support for getting/setting the front panel PSU status led
- Add support for getting the min/max observed temperature value
* [Nokia ixs7215] code review changes: temperature min/max values
Why I did it
Power cycle test case fails for Z9332f in sonic-mgmt framework(#8605).
How I did it
Modified the platform API to return expected strings.
How to verify it
Power cycle the device and verify the reboot reason.
Run sonic-mgmt test_reboot script.
- Why I did it
Update SDK\FW version to 4.4.3326\2008.3326. This version contains:
New Features:
1. Add support for Fast Boot for SN3800
Bug Fixing:
1. In some cases, when the total number of allocations exceeds the resource limit, an error can occur due to incorrect resource release procedure. This issue is most likely to affect the following resources: flow counters, ACL actions, PBS, WJH filter, Tunnels, ECMP containers, MC (L2 &L3)
2. On Spectrum systems, when using Async Router API with IPV6, an error message in the log regarding failing to remove ECMP container may show up. This error is not functional and can be safely ignored.
3. On Spectrum-2 systems and above, when using warm boot, setting max_bridge_num to a value greater than 1968 will cause an error and potential crash.
4. Some Molex cables do not support speed after reboot
- How I did it
Update submodule and .mk files
- How to verify it
Verified by running regression tests that includes complete sonic-mgmt tests supported
Signed-off-by: Shlomi Bitton <shlomibi@nvidia.com>