Commit Graph

12 Commits

Author SHA1 Message Date
Prince Sunny
dd4d2a75f0
[Broadcom] Set hierarchical ecmp levels to 2 (#7370)
Set hierarchical ecmp level to 2 instead of 3. Based on CS00011833367, ecmp level must be set to 2.
This is already handled for TH2 platforms. Change is required only for TD3

Co-authored-by: Ubuntu <prsunny@prince-vm.vzw1i4tqyeburcdz5lrgulxi2c.yx.internal.cloudapp.net>
2021-04-21 13:22:52 -07:00
vmittal-msft
02cc486511
Remove dummy MMU profiles for Arista-7050CX3-32S-C32 and Arista-7050CX3-32S-D48C8 (#6785) 2021-02-17 11:45:00 -08:00
Vaibhav Hemant Dixit
a7ba1b8b43
Add the 10G ports with updated speed (#6699)
Port_config update for hwsku 7050CX3-32S-C3 - add two 10G ports.
This change is added to fix issue of "PortsOrch initialization failure" seen by previous removal of these 10G ports.
Tested on the device with new minigraph, and the PortsOrch initialization failure is not seen.
2021-02-05 19:34:17 -08:00
gechiang
c98e8d6690
[BCM Config] Update TD3 bcm.config files to use ISSU capable premium CANCUN 6.4.1 (#6651) 2021-02-02 21:48:26 -08:00
Vaibhav Hemant Dixit
580666a406
[arista]: 7050CX3-32S-C32: Remove unused 10G ports and update speed (#6638)
port_config.ini for HWSKU Arista-7050CX3-32S-C32 has missing speed column and duplicated lanes.
The incorrect speed causes issues in Orchagent RESTARTCHECK as the below task remains as the remaining item during swss shutdown.
2021-02-02 11:26:36 -08:00
Tamer Ahmed
284c2738e8
[sonic-device-data]: Update BRCM Tunnel/ECMP Parameter For 7050cx3 SKUs (#6415)
Update Tunnel and ECMP parameters for brcm 7050cx3 48x50G+8x100G and 32x100G SKUs.

signed-off-by: Tamer Ahmed <tamer.ahmed@microsoft.com>
2021-01-29 14:15:48 -08:00
Ying Xie
1ba583cb46
[TD3] add dummy MMU configuration for Arista-7050CX3-32S-D48C8 (#5950)
Need A mmu configuration to get the device going without generating lots of warnings.

Similar to dummy MMU configuration for Arista-7050CX3-32S-C32, this configuration will need to be updated with correct numbers. This MMU configuration is copied from 7060 comparable hwsku.

Signed-off-by: Ying Xie <ying.xie@microsoft.com>
2020-11-17 19:01:39 -08:00
Ying Xie
6a8ebef449
[Arista 7050cx3] add dummy MMU configurations for Arista-7050CX3-32S-C32 (#5798)
- Why I did it
On Arista-7050CX3-32S-C32, there are constant stream of errors like following.

Nov 3 21:56:24.415190 str2-7050cx3-acs-06 NOTICE swss#orchagent: :- registerInWdDb: No lossless TC found on port Ethernet68

Which causes:

loganalyzer to claim test failed.
leaving the system without MMU configuration. Which couldn't be good for any IO test.
- How I did it
Added these MMU configuraions are copied from another platform and guaranteed to be incorrect for hwsku Arista-7050CX3-32S-C32.

Adding them so that we have A MMU configuration and the system won't throw a whole bunch of errors and leave MMU unconfigured. The correct MMU configuration will come later.

This configuration is definitely not suitable for testing system performance or QoS behavior.

Signed-off-by: Ying Xie ying.xie@microsoft.com

- How to verify it
Test will have chance to pass. Ran a few test that would fail otherwise.
2020-11-09 13:27:36 -08:00
abdosi
a6a10f05b7
In SAI 3.5 by default we are supporting 256 Group with 64 Memeber each. (#5400)
However in SAI 3.7 default behaviout got changes to 128 Group and 128
    Memeber each.

    This change is to make sure we are using same ECMP Group/Memeber Per
    Group for 3.7 also so that behaviour is consistent.

Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
2020-09-22 11:21:12 -07:00
abdosi
b6efb49817
Update bcm soc property bcm_num_cos from 8 to 10 (#5314)
as needed by SAI 3.7 and above. Without this change
Warmboot fails from 3.5 to 3.7 as Braodcoam Datastructure
gets corrupted after warm-boot.

Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
2020-09-04 07:40:17 -07:00
Samuel Angebault
de4fa1874a
[arista]: remove the soc property disabling sram scan (#4623) 2020-05-20 12:44:48 -07:00
Samuel Angebault
64500e143b [Arista] Update drivers and boot script (#3959)
* Update arista driver submodule

* Add support for 7260CX3-64E in boot0

* Refactor boot0 platform specific definition

Make it easier to manage new sku

* Add support for 7050CX3-32S in boot0

Just contains the required boot0 information

* Add basic plugin support for DCS-7050CX3-32S

* Add port config for Arista-7050CX3-32S-C32

Co-authored-by: yurypm <yurypm@arista.com>
Co-authored-by: byu343 <byu@arista.com>
2020-01-17 10:44:49 -08:00