These devices will not reliabily report the proper devid and vendorid
when reading it is read directly from the pci config space.
It can be read but shouldn't be compared against some fixed value like
the one stored in pcie.yaml.
Since this makes pcied unhappy, the simplest path forward is to just
remove this device from monitoring.
Provide platform-components.json for Clearwater2 and Wolverine
These files are needed for fwutil platform sonic-mgmt tests to pass.
Fix PikeZ platform_components.json
Co-authored-by: Patrick MacArthur <pmacarthur@arista.com>
Co-authored-by: Andy Wong <andywong@arista.com>
Why I did it
The 720DT-48S platform has variants with different chassis names, and these need to all be included in platform_components.json to ensure that sonic-mgmt platform_tests/fwutil/test_fwutil.py::test_fwutil_show passes
How I did it
Updated platform_components.json with the variant names for 720DT-48S.
How to verify it
Ran aforementioned testcase and verified that it passes on the different variants.
Why I did it
This is to fix test_forward_ip_packet_with_0xffff_chksum_tolerant test failure on 720DT-48S. IP packets with checksum set to 0xffff will be forwarded with the same checksum on this platform, instead of updating to the correct value.
How I did it
Add bcm config sai_verify_incoming_chksum=0 so that checksum is updated instead of being left unchanged when checksum is 0xffff. Note that packets with invalid checksum are still dropped with this config.
Why I did it
Added to allow test_crm_route to pass; the test tries to add a /126 ipv6 route and this change is required in order for the count of available routes to be updated correctly.
Why I did it
Add components data for sonic-mgmt testing
How I did it
Update platform.json and add platform_components.json
How to verify it
Ran sonic-mgmt tests (test_chassis and test_component)
Why I did it
Content of platform.json was outdated and some platform_tests/api of sonic-mgmt were failing.
How I did it
Added the necessary values to platform.json
How to verify it
Running platform_tests/api of sonic-mgmt should yield 100% passrate.
Port index 22 is associated with phy23_config.json, then same port index 22 in phy24_config.json may cause gearbox port creation error. Port Ethernet22 maps to index 23.
* Why I did it
Followup to #10656. This change adds the remaining configs for the 720DT-48S platform.
* How I did it
Adds the following:
gearbox_config.json and other gearbox-related config files, to enable traffic on external PHY ports (Ethernet0-23)
sensors.conf
pcie.yaml
Also add missing facts in platform.json
* How to verify it
show interfaces status shows links up on interfaces Ethernet0-23
traffic flows with no errors on interfaces Ethernet0-23
Note: above testing depends on Add gbsyncd container for broncos #11154 and [orchagent]: Enhance initSaiPhyApi sonic-swss#2367, as well as having the appropriate PAI driver.
Co-authored-by: Samuel Angebault <staphylo@arista.com>
Added initial set of config files to allow for booting and partial traffic testing in SONiC on the 720DT-48S.
How to verify it
- Switch boots
- show interfaces status shows links up on interfaces Ethernet24-51
- Traffic flows with no errors on interfaces Ethernet24-51