Why I did it
autoneg is not supported in the previous release 202012 on Nokia-7215 platform. To migrate to the 202205 image with autoneg support, we need to disable the autoneg to allow the link to be up when issue load minigraph. This requires to change the autoneg setting to be off in the port_config.ini file.
How I did it
Modify the port_config.ini to set the autoneg off.
How to verify it
Running the new image, with load mingraph.xml, execute "show int autonet status" should show autoneg disabled
Why I did it
To bring in the following fixes:
Revert temporary fix added to disable SA equal DA drops
CS00012273013 - [7.1][J2, J2c+] Disable SA Equals DA trap on DNX
CS00012274222 - How to block the voq for given destination port for a flow from a remote mod-id
CS00012275381 - SAI_INGRESS_PRIORITY_GROUP_STAT_PACKETS is incremented for port's PG's even if there are no traffic sent to that PG
CS00012274433 - Local Fault and Remote Fault are not polled by linkscan thread
How I did it
Merged above fixes to SAI code
How to verify it
Validated by running the basic sanity tests on XGS and DNX chassis platforms including
fib/test_fib.py
decap/test_decap.py
drop_counters/test_drop_counters.py
arp/test_arpall.py
Why I did it
Update the Nokia-7215 device data which is required by the new version of the Marvell SAI 1.10.2-2 to fix the syncd crash issue.
How I did it
Update the device data in folder device/nokia/armhf-nokia_ixs7215_52x-r0 /Nokia-7215.
How to verify it
With this PR, syncd should be running fine. Syncd should not crash.
Signed-off-by: mlok <marty.lok@nokia.com>
changed the platform device name under nokia directory; we now need to specify marvell armhf/arm64 to provide more accurate platform identity. otherwise onie discovery won't recognize the asic being installed.
Why I did it
when we load images using onie discovery, the process was failing because of marvell ASIC mismatch
How I did it
replace the platform asic with marvell-armhf under 7215
How to verify it
load a new image using http server and verify that the image can be loaded successfully
What/Why I did:
Issue1: By setting up of ipvlan interface in interface-config.sh we are not tolerant to failures. Reason being interface-config.service is one-shot and do not have restart capability.
Scenario: For example if let's say database service goes in fail state then interface-services also gets failed because of dependency check but later database service gets restart but interface service will remain in stuck state and the ipvlan interface nevers get created.
Solution: Moved all the logic in database service from interface-config service which looks more align logically also since the namespace is created here and all the network setting (sysctl) are happening here.With this if database starts we recreate the interface.
Issue 2: Use of IPVLAN vs MACVLAN
Currently we are using ipvlan mode. However above failure scenario is not handle correctly by ipvlan mode. Once the ipvlan interface is created and ip address assign to it and if we restart interface-config or database (new PR) service Linux Kernel gives error "Error: Address already assigned to an ipvlan device." based on this:https://github.com/torvalds/linux/blob/master/drivers/net/ipvlan/ipvlan_main.c#L978Reason being if we do not do cleanup of ip address assignment (need to be unique for IPVLAN) it remains in Kernel Database and never goes to free pool even though namespace is deleted.
Solution: Considering this hard dependency of unique ip macvlan mode is better for us and since everything is managed by Linux Kernel and no dependency for on user configured IP address.
Issue3: Namespace database Service do not check reachability to Supervisor Redis Chassis Server.
Currently there is no explicit check as we never do Redis PING from namespace to Supervisor Redis Chassis Server. With this check it's possible we will start database and all other docker even though there is no connectivity and will hit the error/failure late in cycle
Solution: Added explicit PING from namespace that will check this reachability.
Issue 4:flushdb give exception when trying to accces Chassis Server DB over Unix Sokcet.
Solution: Handle gracefully via try..except and log the message.
The following changes are provided to support bullseye and the latest master
branch content.
- Accommodate relocated fan and thermal sysfs entries in bullseye
- Add support for chassis and PSU HW revision
Why I did it
Fix platform issues introduced by the bullseye kernel upgrade.
How I did it
Minor fixes to Nokia ixs7215 platform code
How to verify it
Execute the following CLI commands
show platform summary
show platform fan
show platform temperature
Added midplane_subnet in chassisdb.conf for interfaces-config.sh to create midplane interface in multi-asic namespaces.
Signed-off-by: Sakthivadivu Saravanaraj <sakthivadivu.saravanaraj@nokia.com>
Why I did it
Updated the BCM config recommended by Broadcom for Nokia-IXR7250E-36x400G
How I did it
Updated the BCM config file
How to verify it
Verified running the image with this BCM config in Nokia-IXR7250E-36x400G and ensured that the syncd container was stable, ports were up and passing the traffic.
Signed-off-by: Sakthivadivu Saravanaraj <sakthivadivu.saravanaraj@nokia.com>
This commit more fully declares the HW capabilities of the Nokia-7215
platform. For example, support for the threshold values associated with each
thermal sensor is described. The intent here is to inform the sonic-mgmt
platform test cases of which HW features are supported.
This commit must align with PR# 4521 within the sonic-mgmt git repo which is
currently under review. Any changes to that PR will need to be reflected in
this commit.
-- Based on the new BCM configuration, Modify the portcoreid for the front panel port in the port_config.ini for line card Nokia-IXR7250e-36x400G
-- Correct the pcie.pmal file
-- Update the platform_ndk.json with new field "update-asic-pvt"
-- Add chassis-internal-intf to chassisdb.conf
-- update platform_reboot
Signed-off-by: mlok <marty.lok@nokia.com>
#### Why I did it
Add platform_asic file to each platform folder in sonic-device-data package. The file content will be used as the ground truth of mapping from PLATFORM_STRING to switch ASIC family.
One use case of the mapping is to prevent installing a wrong image, which targets for other ASIC platforms. For example, currently we have several ONIE images naming as sonic-*.bin, it's easy to mistakenly install the wrong image. With this mapping built into image, we could fetch the ONIE platform string, and figure out which ASIC it is using, and check we are installing the correct image.
After this PR merged, each platform vendor has to add one mandatory text file `device/PLATFORM_VENDOR/PLATFORM_STRING/platform_asic`, with the content of the platform's switch ASIC family.
I will update https://github.com/Azure/SONiC/wiki/Porting-Guide after this PR is merged.
You can get a list of the ASIC platforms by `ls -b platform | cat`. Currently the options are
```
barefoot
broadcom
cavium
centec
centec-arm64
generic
innovium
marvell
marvell-arm64
marvell-armhf
mellanox
nephos
p4
vs
```
Also support
```
broadcom-dnx
```
#### How I did it
#### How to verify it
Test one image on DUT. And check the folders under `/usr/share/sonic/device`
Depends on Azure/sonic-utilities#1626
Depends on Azure/sonic-swss#1754
QOS tables in config db used ABNF format i.e "[TABLE_NAME|name] to refer fieldvalue to other qos tables.
Example:
Config DB:
"Ethernet92|3": {
"scheduler": "[SCHEDULER|scheduler.1]",
"wred_profile": "[WRED_PROFILE|AZURE_LOSSLESS]"
},
"Ethernet0|0": {
"profile": "[BUFFER_PROFILE|ingress_lossy_profile]"
},
"Ethernet0": {
"dscp_to_tc_map": "[DSCP_TO_TC_MAP|AZURE]",
"pfc_enable": "3,4",
"pfc_to_queue_map": "[MAP_PFC_PRIORITY_TO_QUEUE|AZURE]",
"tc_to_pg_map": "[TC_TO_PRIORITY_GROUP_MAP|AZURE]",
"tc_to_queue_map": "[TC_TO_QUEUE_MAP|AZURE]"
},
This format is not consistent with other DB schema followed in sonic.
And also this reference in DB is not required, This is taken care by YANG "leafref".
Removed this format from all platform files to consistent with other sonic db schema.
Example:
"Ethernet92|3": {
"scheduler": "scheduler.1",
"wred_profile": "AZURE_LOSSLESS"
},
Dependent pull requests:
#7752 - To modify platfrom files
#7281 - Yang model
Azure/sonic-utilities#1626 - DB migration
Azure/sonic-swss#1754 - swss change to remove ABNF format
Why I did it
Support Nokia ixr7250E IMM and Supervisor cards
How I did it
Added modules x86_64-nokia_ixr7250e_sup-r0 and x86_64-nokia_ixr7250e_36x400g-r0 ../device/nokia directory.
Modified the platform/broadcom/one-image.mk to include NOKIA_IXR7250_PLATFORM_MODULE
Modified the platform/broadcom/rule.mk to include the platform-module-nokia.mk
Deliver sfputil support for sfputil show eeprom and sfputil reset along with some component test case fixes
Co-authored-by: Carl Keene <keene@nokia.com>
* add hwsku.json for the Nokia-7215
* added required default_brkout_mode to hwsku as its not optional
* remove tabs from the file so spacing consistent
Co-authored-by: Carl Keene <keene@nokia.com>
- Improve sonic-mgmt platform test suite pass rate
- Improve coverage of platform unit tests
- Provide platform specific reboot logic as per platform porting guide
- Fix bug due to pcie.yaml file being located in the wrong directory
- Why I did it
Enable platform API tests to run successfully by providing required test infrastructure files along with supporting changes.
- How I did it
Added platform.json along with supporting changes.
- Addition of pcie.yaml supporting pcied
- Addition of Real fan drawer support vs Virtual
- Removal of python2 wheel with support in place for python3
- supporting changes platform api tests
fix platform driver breakage due to python3 upgrade and fix load minigraph errors with config load_minigraph -y
**- How I did it**
added python3-smbus to the pmon docker template since the previous was python2 specific
fixed additional "ord" python2 specific code
fixed the jinja templates used by qos reload - the template logic required data to be parsed
**- How to verify it**
run "show platform XXX" commands and verify output
run "sudo config load_minigraph -y" and verify configuration
run "show interfaces XXX" and verify output
Co-authored-by: Carl Keene <keene@nokia.com>
Submodule updates include the following commits:
* src/sonic-utilities 9dc58ea...f9eb739 (18):
> Remove unnecessary calls to str.encode() now that the package is Python 3; Fix deprecation warning (#1260)
> [generate_dump] Ignoring file/directory not found Errors (#1201)
> Fixed porstat rate and util issues (#1140)
> fix error: interface counters is mismatch after warm-reboot (#1099)
> Remove unnecessary calls to str.decode() now that the package is Python 3 (#1255)
> [acl-loader] Make list sorting compliant with Python 3 (#1257)
> Replace hard-coded fast-reboot with variable. And some typo corrections (#1254)
> [configlet][portconfig] Remove calls to dict.has_key() which is not available in Python 3 (#1247)
> Remove unnecessary conversions to list() and calls to dict.keys() (#1243)
> Clean up LGTM alerts (#1239)
> Add 'requests' as install dependency in setup.py (#1240)
> Convert to Python 3 (#1128)
> Fix mock SonicV2Connector in python3: use decode_responses mode so caller code will be the same as python2 (#1238)
> [tests] Do not trim from PATH if we did not append to it; Clean up/fix shebangs in scripts (#1233)
> Updates to bgp config and show commands with BGP_INTERNAL_NEIGHBOR table (#1224)
> [cli]: NAT show commands newline issue after migrated to Python3 (#1204)
> [doc]: Update Command-Reference.md (#1231)
> Added 'import sys' in feature.py file (#1232)
* src/sonic-py-swsssdk 9d9f0c6...1664be9 (2):
> Fix: no need to decode() after redis client scan, so it will work for both python2 and python3 (#96)
> FieldValueMap `contains`(`in`) will also work when migrated to libswsscommon(C++ with SWIG wrapper) (#94)
- Also fix Python 3-related issues:
- Use integer (floor) division in config_samples.py (sonic-config-engine)
- Replace print statement with print function in eeprom.py plugin for x86_64-kvm_x86_64-r0 platform
- Update all platform plugins to be compatible with both Python 2 and Python 3
- Remove shebangs from plugins files which are not intended to be executable
- Replace tabs with spaces in Python plugin files and fix alignment, because Python 3 is more strict
- Remove trailing whitespace from plugins files