Commit Graph

11 Commits

Author SHA1 Message Date
andywongarista
372a7c85c5
[Arista] Update ip packet checksum when set to 0xffff on 720DT-48S (#13088)
Why I did it
This is to fix test_forward_ip_packet_with_0xffff_chksum_tolerant test failure on 720DT-48S. IP packets with checksum set to 0xffff will be forwarded with the same checksum on this platform, instead of updating to the correct value.

How I did it
Add bcm config sai_verify_incoming_chksum=0 so that checksum is updated instead of being left unchanged when checksum is 0xffff. Note that packets with invalid checksum are still dropped with this config.
2022-12-17 13:47:05 -08:00
Jing Kan
272f61d0f1
[Arista 720DT] Create SKU alias Arista-720DT-G48S4 (#12905) 2022-12-02 18:53:02 +08:00
andywongarista
e7f4da5823
[Arista] Enable ipv6 128b lpm on 720DT-48S (#12832)
Why I did it
Added to allow test_crm_route to pass; the test tries to add a /126 ipv6 route and this change is required in order for the count of available routes to be updated correctly.
2022-11-29 11:20:50 +08:00
andywongarista
2f46689a05
[Arista] Add components for 720DT-48S (#12217)
Why I did it
Add components data for sonic-mgmt testing

How I did it
Update platform.json and add platform_components.json

How to verify it
Ran sonic-mgmt tests (test_chassis and test_component)
2022-10-03 13:53:34 +08:00
Junhua Zhai
63c14d2e9e
[PikeZ] Update port alias in Arista-720DT-48S (#12086)
Fix #12037, by following HLD https://github.com/sonic-net/SONiC/blob/master/doc/sonic-port-name.md.
2022-09-20 20:04:14 +08:00
Samuel Angebault
f2c9a3584d
[Arista] Fix content of platform.json for DCS-720DT-48S (#11855)
Why I did it
Content of platform.json was outdated and some platform_tests/api of sonic-mgmt were failing.

How I did it
Added the necessary values to platform.json

How to verify it
Running platform_tests/api of sonic-mgmt should yield 100% passrate.
2022-08-29 10:45:24 +08:00
andywongarista
1b83e418f8
Enable AN for Ethernet24-47 (#11839)
Enable port AN ON explicitly and then port will become (oper status) UP. Somehow those ports AN are not default ON in bcm sdk.
2022-08-26 09:30:11 +08:00
Junhua Zhai
abda50c791
Correct port index in Arista-720DT-48S/phy24_config.json (#11699)
Port index 22 is associated with phy23_config.json, then same port index 22 in phy24_config.json may cause gearbox port creation error. Port Ethernet22 maps to index 23.
2022-08-17 12:48:40 +08:00
Jiahua Wang
7683ff5791
[arista]: Add sai_mdio_access_clause22=1 in td3x2-a720dt-48s-flex.config.bcm (#11303)
Add sai_mdio_access_clause22=1 in td3x2-a720dt-48s-flex.config.bcm

Signed-off-by: Jiahua Wang <jiahua.wang@broadcom.com>
2022-07-27 10:04:40 -07:00
andywongarista
07dbc149df
[Arista] Add missing configs for 720DT-48S (#11362)
* Why I did it
Followup to #10656. This change adds the remaining configs for the 720DT-48S platform.

* How I did it
Adds the following:
gearbox_config.json and other gearbox-related config files, to enable traffic on external PHY ports (Ethernet0-23)
sensors.conf
pcie.yaml
Also add missing facts in platform.json

* How to verify it
show interfaces status shows links up on interfaces Ethernet0-23
traffic flows with no errors on interfaces Ethernet0-23
Note: above testing depends on Add gbsyncd container for broncos #11154 and [orchagent]: Enhance initSaiPhyApi sonic-swss#2367, as well as having the appropriate PAI driver.

Co-authored-by: Samuel Angebault <staphylo@arista.com>
2022-07-20 11:36:16 +08:00
andywongarista
6e0559d5fa
[Arista] Add initial support for 720DT-48S (#10656)
Added initial set of config files to allow for booting and partial traffic testing in SONiC on the 720DT-48S.

How to verify it
- Switch boots
- show interfaces status shows links up on interfaces Ethernet24-51
- Traffic flows with no errors on interfaces Ethernet24-51