Signed-off-by: Dror Prital <drorp@nvidia.com>
* [Mellanox] Update FW version to 2008.3218 (#8079)
Update FW version to 2008.3218, fixing the following issues:
- 50G/100G links that are operationally down before warm-reboot are not coming up after warm-reboot
- 50G/100G links with admin shut / no shut commands are not coming up after warm-reboot
In the multi asic platforms all the ASIC are advertising the same IPv6 /64 network from Loopback4096.
Therefore, the IPv6 loopback address of backend asic is not learnt on the frontend asic.
Change this to advertise the Loopback4096 address as /128
In upgrade scenarios, where config_db.json is not carry forwarded to new image, it could be left w/o TACACS credentials.
Added a service to trigger 5 minutes after boot and restore TACACS, if /etc/sonic/old_config/tacacs.json is present.
How I did it
By adding a service, that would fire 5 mins after boot.
This service apply tacacs if available.
How to verify it
Upgrade and watch status of tacacs.timer & tacacs.service
You may create /etc/sonic/old_config/tacacs.json, with updated credentials
(before 5mins after boot) and see that appears in config & persisted too.
Why I did it
7050 S4Q31 mmu configuration is missing ALPM configurations, causing not enough memory reserved for routes. Orchagent crashes on a nightly testbed with 6400 route entries.
How I did it
Add the missing ALPM configurations.
How to verify it
Load the configuration on testbed and verified new configuration exists and no more crash.
Signed-off-by: Ying Xie ying.xie@microsoft.com
33f370f890c525512668583a7f4e231415b28738 (HEAD -> 201911, origin/201911)
[vnet/vxlan] Add support of multiple mappers for the VxLAN tunnel
(#1753)
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
- Why I did it
Update FW version to 2008_3110 fixing SN3800 specific warm boot scenario:
1. Disable interface
2. Warm Boot
3. Enable Interface --> link will remain down.
- How I did it
Use new FW that contains the fix for the problem mentioned above
- How to verify it
Run the scenario mentioned above and make sure that the link is up after warm boot
Signed-off-by: Dror Prital <drorp@nvidia.com>
Encounter error during "config-setup boot" if the updategraph is enabled.
How I did it
Correct the code inside the config-setup script.
Remove the space between the assignment operator.
How to verify it
Remove the /etc/sonic/config_db.json and reboot the device.
Originally, it will return following error after boot up.
rv: command not found
After modification, it can correctly parse the status of updategraph without error.
LED_PROC_INIT_SOC variable was incorrectly referenced as LED_SOC_INIT_SOC. Introduced in #5483
Rather than fixing the typo, I decided to simplify the script, removing the need for the conditional altogether by moving the bcmcmd call inside the conditional which checks for the presence of LED_SOC_INIT_SOC.
This PR contains the following changes
Original Arista-7050-QX-32S sku (32x40G ports) has been renamed to Arista-7050QX32S-Q32
Arista-7050-QX-32S is symlinked to Arista-7050QX-32S-S4Q31 (4x10G, 31x40G ports)
Signed-off-by: Neetha John <nejo@microsoft.com>
Signed-off-by: Neetha John <nejo@microsoft.com>
Why I did it
Need proper MMU and Qos settings for Arista-7050QX-32S-S4Q31
How I did it
Updated the settings based on Arista-7050-QX-32S
09457e524797bd988e011e24250a5e5c942bfdf2 (HEAD -> 201911, origin/201911)[tunneldecaporch] Set default MTU for the overlay loopback interface (#1756)
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
#### Why I did it
1. Update pg_profile_lookup.ini with 2000m cable supported
2. Update buffer configuration for t1 with uplink cable 2000m
- For SN3800 platform:
- C64:
- t0: 32 100G down links and 32 100G up links.
- t1: 56 100G down links and 8 100G up links with 2 km cable.
- D112C8: 112 50G down links and 8 100G up links.
- D24C52: 24 50G down links, 20 100G down links, and 32 100G up links.
- D28C50: 28 50G down links, 18 100G down links, and 32 100G up links.
- For SN2700 platform:
- D48C8: 48 50G down links and 8 100G up links
- C32:
- t0: 16 100G down links and 16 100G up links.
- t1: 24 100G down links and 8 100G up links with 2 km cable.
Signed-off-by: Stephen Sun <stephens@nvidia.com>
#### How I did it
#### How to verify it
Run QoS regression test
#### Why I did it
Microsoft reported occasional daemon crashes on devices running 201911. On close inspection it was due to PMBus reads failing on IOError on very rare occasions.
#### How I did it
Add try/except block on performing reads on PMBus GPIOs.
Co-authored-by: Zhi Yuan (Carl) Zhao <zyzhao@arista.com>
Why I did it
To recover the SSD upgrade state in case, if ONIE-uninstall or ssd_fw_upgrade folder got deleted.
To handle newer SSD version(S21506G - 3IE GPIO7 low devices).
Also correcting the error messages for non-upgraded S6100s.
#### Why I did it
The label for PSU related sensors on the Spectrum-2 platform is not aligned with the physical location of the PSU.
#### How I did it
Update the label in the sensor conf file for those relevant platforms
Signed-off-by: Kebo Liu <kebol@nvidia.com>