* Updated default ECN settings for T2 chassis (#14388)
Why I did it
Update ECN settings for T2 chassis
How I did it
Updated qos config file to load these settings during switch bootup
How to verify it
Verified on line card on T2 chassis
* Fix for test failures
* Test case failures
* test case fix
Why I did it
Update cable length for uplink/downlink ports for chassis and and update PG/pool headroom size accordingly.
Work item tracking
17880812
How I did it
Updated cable length as well as buffer config in HWSKU files.
Why I did it
When reboot the chassis by issuing "sudo reboot" on Supervisor card. The internal midplane communication xe0 should be shutdown to avoid double reboot on the linecard.
Added a udev link rule to disable the autoneg on AMD xgbe port Xe0 and Xe1 and make the setting in sync with the peer Broadcom greyhound ports.
How I did it
Modify the Nokia-7250IXRE specific reboot script on the Supervisor card to shutdown the internal interface xe0. Also move reboot linecard code to the top of the script to make sure the notification has been send to Linecard before shutdown the xe0 interface.
Introduced a new rule 80-net-by-driver.link to disable the autoneg on the AMD size. This change requires the latest NDK which contains the change to set the autoneg on the xe0 and xe1 port on the Greyhound.
Signed-off-by: mlok <marty.lok@nokia.com>
Why I did it
Add support for SFP refactor on Nokia-7215 Marvell armhf platform.
Platform: armhf-nokia_ixs7215_52x-r0
HwSKU: Nokia-7215
ASIC: marvell
Port Config: 48x1G + 4x10G (SFP+)
How I did it
Modify sfp.py to support SFP refactor optoe driver and platform.json to facilitate proper OC test completion.
How to verify it
Build armhf target for Nokia-7215 and verify proper Xcvrd and SFP refactor operation.
Why I did it
autoneg is not supported in the previous release 202012 on Nokia-7215 platform. To migrate to the 202205 image with autoneg support, we need to disable the autoneg to allow the link to be up when issue load minigraph. This requires to change the autoneg setting to be off in the port_config.ini file.
How I did it
Modify the port_config.ini to set the autoneg off.
How to verify it
Running the new image, with load mingraph.xml, execute "show int autonet status" should show autoneg disabled
Why I did it
To bring in the following fixes:
Revert temporary fix added to disable SA equal DA drops
CS00012273013 - [7.1][J2, J2c+] Disable SA Equals DA trap on DNX
CS00012274222 - How to block the voq for given destination port for a flow from a remote mod-id
CS00012275381 - SAI_INGRESS_PRIORITY_GROUP_STAT_PACKETS is incremented for port's PG's even if there are no traffic sent to that PG
CS00012274433 - Local Fault and Remote Fault are not polled by linkscan thread
How I did it
Merged above fixes to SAI code
How to verify it
Validated by running the basic sanity tests on XGS and DNX chassis platforms including
fib/test_fib.py
decap/test_decap.py
drop_counters/test_drop_counters.py
arp/test_arpall.py
Why I did it
Update the Nokia-7215 device data which is required by the new version of the Marvell SAI 1.10.2-2 to fix the syncd crash issue.
How I did it
Update the device data in folder device/nokia/armhf-nokia_ixs7215_52x-r0 /Nokia-7215.
How to verify it
With this PR, syncd should be running fine. Syncd should not crash.
Signed-off-by: mlok <marty.lok@nokia.com>
changed the platform device name under nokia directory; we now need to specify marvell armhf/arm64 to provide more accurate platform identity. otherwise onie discovery won't recognize the asic being installed.
Why I did it
when we load images using onie discovery, the process was failing because of marvell ASIC mismatch
How I did it
replace the platform asic with marvell-armhf under 7215
How to verify it
load a new image using http server and verify that the image can be loaded successfully
What/Why I did:
Issue1: By setting up of ipvlan interface in interface-config.sh we are not tolerant to failures. Reason being interface-config.service is one-shot and do not have restart capability.
Scenario: For example if let's say database service goes in fail state then interface-services also gets failed because of dependency check but later database service gets restart but interface service will remain in stuck state and the ipvlan interface nevers get created.
Solution: Moved all the logic in database service from interface-config service which looks more align logically also since the namespace is created here and all the network setting (sysctl) are happening here.With this if database starts we recreate the interface.
Issue 2: Use of IPVLAN vs MACVLAN
Currently we are using ipvlan mode. However above failure scenario is not handle correctly by ipvlan mode. Once the ipvlan interface is created and ip address assign to it and if we restart interface-config or database (new PR) service Linux Kernel gives error "Error: Address already assigned to an ipvlan device." based on this:https://github.com/torvalds/linux/blob/master/drivers/net/ipvlan/ipvlan_main.c#L978Reason being if we do not do cleanup of ip address assignment (need to be unique for IPVLAN) it remains in Kernel Database and never goes to free pool even though namespace is deleted.
Solution: Considering this hard dependency of unique ip macvlan mode is better for us and since everything is managed by Linux Kernel and no dependency for on user configured IP address.
Issue3: Namespace database Service do not check reachability to Supervisor Redis Chassis Server.
Currently there is no explicit check as we never do Redis PING from namespace to Supervisor Redis Chassis Server. With this check it's possible we will start database and all other docker even though there is no connectivity and will hit the error/failure late in cycle
Solution: Added explicit PING from namespace that will check this reachability.
Issue 4:flushdb give exception when trying to accces Chassis Server DB over Unix Sokcet.
Solution: Handle gracefully via try..except and log the message.
The following changes are provided to support bullseye and the latest master
branch content.
- Accommodate relocated fan and thermal sysfs entries in bullseye
- Add support for chassis and PSU HW revision
Why I did it
Fix platform issues introduced by the bullseye kernel upgrade.
How I did it
Minor fixes to Nokia ixs7215 platform code
How to verify it
Execute the following CLI commands
show platform summary
show platform fan
show platform temperature
Added midplane_subnet in chassisdb.conf for interfaces-config.sh to create midplane interface in multi-asic namespaces.
Signed-off-by: Sakthivadivu Saravanaraj <sakthivadivu.saravanaraj@nokia.com>
Why I did it
Updated the BCM config recommended by Broadcom for Nokia-IXR7250E-36x400G
How I did it
Updated the BCM config file
How to verify it
Verified running the image with this BCM config in Nokia-IXR7250E-36x400G and ensured that the syncd container was stable, ports were up and passing the traffic.
Signed-off-by: Sakthivadivu Saravanaraj <sakthivadivu.saravanaraj@nokia.com>
This commit more fully declares the HW capabilities of the Nokia-7215
platform. For example, support for the threshold values associated with each
thermal sensor is described. The intent here is to inform the sonic-mgmt
platform test cases of which HW features are supported.
This commit must align with PR# 4521 within the sonic-mgmt git repo which is
currently under review. Any changes to that PR will need to be reflected in
this commit.
-- Based on the new BCM configuration, Modify the portcoreid for the front panel port in the port_config.ini for line card Nokia-IXR7250e-36x400G
-- Correct the pcie.pmal file
-- Update the platform_ndk.json with new field "update-asic-pvt"
-- Add chassis-internal-intf to chassisdb.conf
-- update platform_reboot
Signed-off-by: mlok <marty.lok@nokia.com>
#### Why I did it
Add platform_asic file to each platform folder in sonic-device-data package. The file content will be used as the ground truth of mapping from PLATFORM_STRING to switch ASIC family.
One use case of the mapping is to prevent installing a wrong image, which targets for other ASIC platforms. For example, currently we have several ONIE images naming as sonic-*.bin, it's easy to mistakenly install the wrong image. With this mapping built into image, we could fetch the ONIE platform string, and figure out which ASIC it is using, and check we are installing the correct image.
After this PR merged, each platform vendor has to add one mandatory text file `device/PLATFORM_VENDOR/PLATFORM_STRING/platform_asic`, with the content of the platform's switch ASIC family.
I will update https://github.com/Azure/SONiC/wiki/Porting-Guide after this PR is merged.
You can get a list of the ASIC platforms by `ls -b platform | cat`. Currently the options are
```
barefoot
broadcom
cavium
centec
centec-arm64
generic
innovium
marvell
marvell-arm64
marvell-armhf
mellanox
nephos
p4
vs
```
Also support
```
broadcom-dnx
```
#### How I did it
#### How to verify it
Test one image on DUT. And check the folders under `/usr/share/sonic/device`
Depends on Azure/sonic-utilities#1626
Depends on Azure/sonic-swss#1754
QOS tables in config db used ABNF format i.e "[TABLE_NAME|name] to refer fieldvalue to other qos tables.
Example:
Config DB:
"Ethernet92|3": {
"scheduler": "[SCHEDULER|scheduler.1]",
"wred_profile": "[WRED_PROFILE|AZURE_LOSSLESS]"
},
"Ethernet0|0": {
"profile": "[BUFFER_PROFILE|ingress_lossy_profile]"
},
"Ethernet0": {
"dscp_to_tc_map": "[DSCP_TO_TC_MAP|AZURE]",
"pfc_enable": "3,4",
"pfc_to_queue_map": "[MAP_PFC_PRIORITY_TO_QUEUE|AZURE]",
"tc_to_pg_map": "[TC_TO_PRIORITY_GROUP_MAP|AZURE]",
"tc_to_queue_map": "[TC_TO_QUEUE_MAP|AZURE]"
},
This format is not consistent with other DB schema followed in sonic.
And also this reference in DB is not required, This is taken care by YANG "leafref".
Removed this format from all platform files to consistent with other sonic db schema.
Example:
"Ethernet92|3": {
"scheduler": "scheduler.1",
"wred_profile": "AZURE_LOSSLESS"
},
Dependent pull requests:
#7752 - To modify platfrom files
#7281 - Yang model
Azure/sonic-utilities#1626 - DB migration
Azure/sonic-swss#1754 - swss change to remove ABNF format
Why I did it
Support Nokia ixr7250E IMM and Supervisor cards
How I did it
Added modules x86_64-nokia_ixr7250e_sup-r0 and x86_64-nokia_ixr7250e_36x400g-r0 ../device/nokia directory.
Modified the platform/broadcom/one-image.mk to include NOKIA_IXR7250_PLATFORM_MODULE
Modified the platform/broadcom/rule.mk to include the platform-module-nokia.mk
Deliver sfputil support for sfputil show eeprom and sfputil reset along with some component test case fixes
Co-authored-by: Carl Keene <keene@nokia.com>
* add hwsku.json for the Nokia-7215
* added required default_brkout_mode to hwsku as its not optional
* remove tabs from the file so spacing consistent
Co-authored-by: Carl Keene <keene@nokia.com>
- Improve sonic-mgmt platform test suite pass rate
- Improve coverage of platform unit tests
- Provide platform specific reboot logic as per platform porting guide
- Fix bug due to pcie.yaml file being located in the wrong directory
- Why I did it
Enable platform API tests to run successfully by providing required test infrastructure files along with supporting changes.
- How I did it
Added platform.json along with supporting changes.
- Addition of pcie.yaml supporting pcied
- Addition of Real fan drawer support vs Virtual
- Removal of python2 wheel with support in place for python3
- supporting changes platform api tests
fix platform driver breakage due to python3 upgrade and fix load minigraph errors with config load_minigraph -y
**- How I did it**
added python3-smbus to the pmon docker template since the previous was python2 specific
fixed additional "ord" python2 specific code
fixed the jinja templates used by qos reload - the template logic required data to be parsed
**- How to verify it**
run "show platform XXX" commands and verify output
run "sudo config load_minigraph -y" and verify configuration
run "show interfaces XXX" and verify output
Co-authored-by: Carl Keene <keene@nokia.com>