* [TPID CONFIG]TPID attribute Yang model and default TPID for Minigraph to configDB Changes
* Fixed alignment spacing issue, removed length and convert to use tpid_type typedef for both LAG and PORT tpid attribute, added description in port and portchannel leaf for the tpid attribute
Make sure Everflow always gets classified as Mirror table and not as Control Plane on multi-asic platforms.
Why I did:
In Multi-asic platforms we generate Everflow acl table data from minigraph for both host and namespace.
It is possible in multi-asic minigraph if there are no external port-channel (Only Router Port IP Interface) then Everflow table will have no binded interface in host and will gets classified as Control Plane ACL while in namespace gets classified as Mirror Table.
For ACL Rule generation we read global db as source of truth for acl table information and so for everflow rule generation if tables gets classified as Control plane we can generate rules with invalid action causing orchagent to throw runtime error.
How I did:
If the table is attach to erspan interface in minigraph then it always gets classified as mirror table.
Parse the value `AutoNegotiation` element from the `LinkMetadata` section of minigraph file. If the element is present, an `autoneg` key will be added to the port in the `PORT` table of Config DB with a value of either `off` or `on`
If an `autoneg` value is present in port_config.ini, the value from the minigraph will take precedence, overriding that value.
Also remove `AutoNegotiation` and `EnableAutoNegotiation` elements from the `DeviceInfo` section, as we will use this data in the `LinkMetadata` section to determine whether to enable auto-negotiation for a port.
1. Made the command next-hop-self force only applicable on back-end asic bgp. This is done so that BGPL iBGP session running on backend can send e-BGP learn nexthop. Back end asic FRR is able to recursively resolve the eBGP nexthop in its routing table since it knows about all the connected routes advertise from front end asic.
2. Made all front-end asic bgp use global loopback ip (Loopback0) as router id and back end asic bgp use Loopbacl4096 as ruter-id and originator id for Route-Reflector. This is done so that routes learnt by external peer do not see Loopback4096 as router id in show ip bgp <route-prerfix> output.
3. To handle above change need to pass Loopback4096 from BGP manager for jinja2 template generation. This was missing and this change/fix is needed for this also https://github.com/Azure/sonic-buildimage/blob/master/dockers/docker-fpm-frr/frr/bgpd/templates/dynamic/instance.conf.j2#L27
4. Enhancement to add mult_asic specific bgpd template generation unit test cases.
* Initial commit for BGP internal neighbor table support.
> Add new template named "internal" for the internal BGP sessions
> Add a new table in database "BGP_INTERNAL_NEIGHBOR"
> The internal BGP sessions will be stored in this new table "BGP_INTERNAL_NEIGHBOR"
* Changes in template generation tests with the introduction of internal neighbor template files.
Issue was because we were relying on port_alias_asic_map dictionary
but that dictionary can't be used as alias name format has changed.
Fix the port alias mapping as what is needed.
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
Jinja2 templates rendered using Python 3 interpreter, are required
to conform with Python 3 new semantics.
singed-off-by: Tamer Ahmed <tamer.ahmed@microsoft.com>
Natural sorting of SONiC config gen output consumes lot of CPU cycles.
The sole use of natsorted was to make test comparison easier and so,
the natsorting logic is now relocated to the test suite. As a result
sonic-cfggen gained nearly 1 sec per call since we no longer import
natsorted module!
singed-off-by: Tamer Ahmed <tamer.ahmed@microsoft.com>
Signed-off-by: Arvindsrinivasan Lakshmi Narasimhan arlakshm@microsoft.com
The following common APIs are added for multi ASIC
- an API to check if a given port is a internal or external port
- an API to check if a given port-channel is internal or external
- an API to check if a bgp-session is internal or external
- an API to connect to the config and other dbs in the a given namespace
- added common APIs to the sonic_py_common library.
- update the sample port-config.ini with role column and add corresponding test to verify the ports configuration is - generated properly.
Resubmitting the changes for (#4825) with fixes for sonic-bgpcdgd test failures
Signed-off-by: Arvindsrinivasan Lakshmi Narasimhan <arlakshm@microsoft.com>
* Loopback IP changes for multi ASIC devices
multi ASIC will have 2 Loopback Interfaces
- Loopback0 has globally unique IP address, which is advertised by the multi ASIC device to its peers.
This way all the external devices will see this device as a single device.
- Loopback4096 is assigned an IP address which has a scope is within the device. Each ASIC has a different ip address for Loopback4096. This ip address will be used as Router-Id by the bgp instance on multi ASIC devices.
This PR implements this change for multi ASIC devices
Signed-off-by: Arvindsrinivasan Lakshmi Narasimhan <arlakshm@microsoft.com>
* The following changes for multi-npu platforms are done
- Set the type in device_metadata for asic configuration to be same as host
- Set the admin-status of internal bgp sessions as up
Signed-off-by: Arvindsrinivasan Lakshmi Narasimhan <arlakshm@microsoft.com>
* [sonic-buildimage] updated minigraph for ACL Table data and ACL Interface
binding update for multu-npu platform based on subrole as "Frontend" or
"Backend". For backend npu no ACL table is associated. For frontend npu
only front-panel interface are associated.
Updated with test case and fix typo in sample-mingraph for npu
Address Review comments
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
* Fixed the logic as per preview comment. Interface Filter logic
only applies to Everflow/Mirror tables.
* Address Review Comments.
* Changes for LLDP for Multi NPU Platoforms:-
a) Enable LLDP for Host namespace for Management Port
b) Make sure Management IP is avaliable in per asic namespace
needed for LLDP Chassis configuration
c) Make sure chassis mac-address is correct in per asic namespace
d) Do not run lldp on eth0 of per asic namespace and avoid chassis
configuration for same
e) Use Linux hostname instead from Device Metadata for lldp chassis
configuration since in multi-npu platforms device metadata hostname
will be differnt
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
* Address Review Comment with following changes:
a) Use Device Metadata hostname even in per namespace conatiner.
updated minigraph parsing for same to have hostname as system
hostname and add new key for asic name
b) Minigraph changes to have MGMT_INTERFACE Key in per asic/namespace
config also as needed for LLDP for setting chassis management IP.
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
* Address Review Comments
- Changes to minigraph.py to parse minigraph.xml of a multi asic platform
- Changes to portconfig.py to parse additional column "asic_port_name" in
port_config.ini
- Add a new option -n to sonic-cfggen for multi asic platforms
- Add unit tests for config generation for multi asic platforms
Signed-off-by: SuvarnaMeenakshi <sumeenak@microsoft.com>
Signed-off-by: Arvindsrinivasan Lakshmi Narasimhan <arlakshm@microsoft.com>