Signed-off-by: Stepan Blyschak stepanb@nvidia.com
This PR is part of SONiC Application Extension
Depends on #5938
- Why I did it
To provide an infrastructure change in order to support SONiC Application Extension feature.
- How I did it
Label every installable SONiC Docker with a minimal required manifest and auto-generate packages.json file based on
installed SONiC images.
- How to verify it
Build an image, execute the following command:
admin@sonic:~$ docker inspect docker-snmp:1.0.0 | jq '.[0].Config.Labels["com.azure.sonic.manifest"]' -r | jq
Cat /var/lib/sonic-package-manager/packages.json file to verify all dockers are listed there.
Fix#7364
99-default.link - was always in SONiC, but previous systemd (<247) had an issue and it did not work due to issue systemd/systemd#3374. Now systemd 247 works.
However, such policy overrides teamd provided mac address which causes teamd netdev to use a random mac
address. Therefore, needs to be disabled.
Signed-off-by: Stepan Blyschak <stepanb@nvidia.com>
#### Why I did it
To build flashrom properly with dependency tracking.
#### How I did it
Moved flashrom code from platform/broadcom/sonic-platform-modules-dell/tools directory to src/flashrom directory.
At the end, flashrom_0.9.7_amd64.deb package is build which will be installed in the devices.
- Support compile sonic arm image on arm server. If arm image compiling is executed on arm server instead of using qemu mode on x86 server, compile time can be saved significantly.
- Add kernel argument systemd.unified_cgroup_hierarchy=0 for upgrade systemd to version 247, according to #7228
- rename multiarch docker to sonic-slave-${distro}-march-${arch}
Co-authored-by: Xianghong Gu <xgu@centecnetworks.com>
Co-authored-by: Shi Lei <shil@centecnetworks.com>
Signed-off-by: vedganes <vedavinayagam.ganesan@nokia.com>
Changes for setting platfrom specific lag id boundary id in the chassis
app db. The platfrom specific lag id boundaries are supplied via
chassisdb.conf. The lag_id_start and lag_id_end boundary values sourced
from this file are set in chassis app db which will be used by lag id
allocator to allocate unique lag id in atomic fashion
- Why I did it
I made the docker_img_ctl.j2 applicable for more dockers (including application extensions dockers) by adding an option not to mount tmpfs on /tmp/ and /var/tmp/. In some applications /tmp/ is a different docker volume which can't be tmpfs.
Also, I added and ability to pass REPO[:TAG]|[@digest]/IMAGE_ID instead of just REPO name.
- How I did it
Modified docker_img_ctl.j2 and docker makefiles.
- How to verify it
Run it on the switch.
- Why I did it
To allow SONiC Package Migration during SONiC-2-SONiC upgrade we need to start docker daemon in chroot-ed environment in new SONiC filesystem.
Later this script will be used to start dockerd in chroot environment on SONiC
- How I did it
Install a docker service script into /usr/lib/docker/ in SONiC filesystem.
- How to verify it
Install SONiC image on the switch, mount squashfs to some directory, mount overlay rw layer over squashfs, mount procfs and sysfs, mount docker library. Start the docker using:
root@sonic:~$ /usr/lib/docker/docker.sh start
Signed-off-by: Stepan Blyshchak <stepanb@nvidia.com>
Why I did it
We skip install of CNI plugin, as we don't need. But this leaves node in "not ready" state, upon joining master.
To fix, we copy this dummy .conf file in /etc/cni/net.d
How I did it
Keep this file in /usr/share/sonic/templates and copy to /etc/cni/net.d upon joining k8s master.
How to verify it
Upon configuring master-IP and enable join, watch node join and move to ready state.
You may verify using kubectl get nodes command
SONiC Package Manager will require to auto-generate the start script using that template. For that, we need this template to be recorded in SONiC filesystem.
Signed-off-by: Stepan Blyshchak <stepanb@nvidia.com>
- Why I did it
Group all SONiC services together and able to manage them together. Will be used in config reload command as much simpler and generic way to restart services.
- How I did it
Add services to sonic.target
- How to verify it
Together with Azure/sonic-utilities#1199
config reload -y
Signed-off-by: Stepan Blyshchak <stepanb@nvidia.com>
- Why I did it
The pcie configuration file location is under plugin directory not under platform directory.
#6437
- How I did it
Move all pcie.yaml configuration file from plugin to platform directory.
Remove unnecessary timer to start pcie-check.service
Move pcie-check.service to sonic-host-services
- How to verify it
Verify on the device
* Add *MUX_CABLE_TABLE* to set of tables to clear on SWSS start, which
will clear HW_MUX_CABLE_TABLE and MUX_CABLE_TABLE
* Order swss to start before pmon to ensure that DBs are cleared before
xcvrd (running inside pmon) starts and re-populates the tables
Signed-off-by: Lawrence Lee <lawlee@microsoft.com>
Fix marvell-armhf build break
The azure-storage package depends on the cryptography package. Newer
versions of cryptography require the rust compiler, the correct version
for which is not readily available in buster. Hence we pre-install an
older version here to satisfy the azure-storage dependency.
Note: This is not a problem for other architectures as pre-built versions
of cryptography are available for those. This sequence can be removed
after upgrading to debian bullseye.
**- Why I did it**
To support FW upgrade on init.
**- How I did it**
Change timeout value
**- How to verify it**
I manually changed ASIC and Gearbox FW followed by hard reset in order for FW upgrade to take place on init.
Signed-off-by: liora <liora@nvidia.com>
- Why I did it
To move ‘sonic-host-service’ which is currently built as a separate package to ‘sonic-host-services' package.
- How I did it
- Moved 'sonic-host-server' to 'src/sonic-host-services' and included it as part of the python3 wheel.
- Other files were moved to 'src/sonic-host-services-data' and included as part of the deb package.
- Changed build option ‘INCLUDE_HOST_SERVICE’ to ‘ENABLE_HOST_SERVICE_ON_START’ for enabling sonic-hostservice at boot-up by default.
[multi_asic][vs]: Add dependency in teamd service to start after topology service.
- Why I did it
In multi-asic VS, topology service is run after database service to set up the internal asic topology.
swss and syncd have a dependency to start after topology service is run so that the interfaces are moved to right namespace and created in the right namespace. In case of multi-asic vs, during the initial boot up, when there is no configuration added, teamd service starts and swss/syncd do not start as topology service does not start. Upon loading configuration using config_db or minigraph, swss and sycnd start up , but teamd is not restarted as swss is not stopped and started. This causes teamd to be in a bad state and requires a reload of config.
- How I did it
Add dependency in teamd service to start after topology service is completed.
- How to verify it
No change in single asic vs or platform.
No change in multi-asic regular image.
Change only in multi-asic VS. Bring up a multi-asic VS image without any configration, teamd service will fail to start due to dependency failure. Load minigraph, start topology service, load configuration, ensure all services come up.
Signed-off-by: SuvarnaMeenakshi <sumeenak@microsoft.com>
Following changes were done for ebtables:
- Support for Multi-asic platforms. Ebtable filters are installed in namespace for multi-asic and not host. On Single asic installed on host.
- For Multi-asic platforms we don't want to install on host otherwise Namespace-to-Namespace communication does not happens since ARP Request are not forwarded.
- Updated to use text file to restore ebtables rules then the binary format. Rules are restore as part of Database docker init instead of rc.local
- Removed the ebtable service files for buster as not needed as filters are restored/installed as part of database docker init.
All the binaries are pre-installed with ebtables* binary are same as ebatbles-legacy-*
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
The Portchannels were not getting cleaned up as the cleanup activity was taking more than 10 secs which is default docker timeout after which a SIGKILL will be send.
Fixes#6199
To check if it works out for this issue in 201911 ? #6503
This issue is significantly seen in master branch compared to 201911 because the Portchannel cleanup takes more time in master. Test on a DUT with 8 Port Channels.
master
admin@str-s6000-acs-8:~$ time sudo systemctl stop teamd
real 0m15.599s
user 0m0.061s
sys 0m0.038s
Sonic 201911.v58
admin@str-s6000-acs-8:~$ time sudo systemctl stop teamd
real 0m5.541s
user 0m0.020s
sys 0m0.028s
**- Why I did it**
This PR aims to monitor the running status of each container. Currently the auto-restart feature was enabled. If a critical process exited unexpected, the container will be restarted. If the container was restarted 3 times during 20 minutes, then it will not run anymore unless we cleared the flag using the command `sudo systemctl reset-failed <container_name>` manually.
**- How I did it**
We will employ Monit to monitor a script. This script will generate the expected running container list and compare it with the current running containers. If there are containers which were expected to run but were not running, then an alerting message will be written into syslog.
**- How to verify it**
I tested this feature on a lab device `str-a7050-acs-3` which has single ASIC and `str2-n3164-acs-3` which has a Multi-ASIC. First I manually stopped a container by running the command `sudo systemctl stop <container_name>`, then I checked whether there was an alerting message in the syslog.
Signed-off-by: Yong Zhao <yozhao@microsoft.com>
- Make PDDF code compliant with both Python 2 and Python 3
- Align code with PEP8 standards using autopep8
- Build and install both Python 2 and Python 3 PDDF packages
swss/teamd/syncd services were changed to always enabled
in commit fad481edc1 as a workaround
for not letting hostcfgd start service during the bootup process.
commit 317a4b3410 introduce
wait till full system bootup before updating feature states in hostcfgd.
Thus, workaround introduced in commit fad481ed can be removed
Signed-off-by: Guohan Lu <lguohan@gmail.com>
Signed-off-by: Prabhu Sreenivasan prabhu.sreenivasan@broadcom
What I did
Added support for snat, dnat and ipmc resources under CRM module.
How I did it
New feature NAT adds new resources snat_enty and dnat_entry that needs to be monitored. ipmc_entry tracks IP multicast resources used by switch.
How to verify it
sonic-utilities tests and crm spytest
* First cut image update for kubernetes support.
With this,
1) dockers dhcp_relay, lldp, pmon, radv, snmp, telemetry are enabled
for kube management
init_cfg.json configure set_owner as kube for these
2) Each docker's start.sh updated to call container_startup.py to register going up
As part of this call, it registers the current owner as local/kube and its version
The images are built with its version ingrained into image during build
3) Update all docker's bash script to call 'container start/stop/wait' instead of 'docker start/stop/wait'.
For all locally managed containers, it calls docker commands, hence no change for locally managed.
4) Introduced a new ctrmgrd service, that helps with transition between owners as kube & local and carry over any labels update from STATE-DB to API server
5) hostcfgd updated to handle owner change
6) Reboot scripts are updatd to tag kube running images as local, so upon reboot they run the same image.
7) Added kube_commands.py to handle all updates with Kubernetes API serrver -- dedicated for k8s interaction only.
Added source interface support for NTP.
Also made NTP start on Mgmt-VRF by default when configured.
**- How I did it**
1) Updated hostcfg to listen to global config NTP and NTP_SERVER tables and restart ntp when ever the configuration changes. NTP table includes source interface configuration.
2) The ntp script updated to by default start on Mgmt-VFT when configured.
Signed-off-by: Prabhu Sreenivasan <prabhu.sreenivasan@broadcom>
Fixes#5663
- Why I did it
It's currently possible for the SNMP timer to conflict with config reload (specifically if the timer triggers while config reload is stopping the SWSS service). config reload triggers SWSS to shutdown, which causes SNMP to shutdown, which conflicts with the SNMP timer causing SNMP to startup. See the linked issue for more details.
- How I did it
Including the After ordering dependency forces the SNMP timer to wait until SWSS finishes stopping, preventing the conflict. If there is an ordering dependency between two units (e.g. one unit is ordered After another), if one unit is shutting down while the other is starting up, the shutdown will always be ordered before the startup. In this case, that means that the SNMP timer is forced to wait for the SWSS shutdown to complete. Only then can the SNMP timer proceed. See here for more details.
It's important to note that the After dependency will not cause SWSS to be started when the SNMP timer fires (assuming that SWSS has not yet been started). The existing Requisite dependency in the SNMP service will also not cause SWSS to be started, instead it will cause the SNMP service to fail if SWSS is not active.
Signed-off-by: Lawrence Lee <lawlee@microsoft.com>
Install the 'wheel' package in host OS (along with python3 and python3-distutils which are also needed for building some Python packages) to eliminate error messages like the following:
```
Running setup.py bdist_wheel for watchdog: started
Running setup.py bdist_wheel for watchdog: finished with status 'error'
Complete output from command /usr/bin/python -u -c "import setuptools, tokenize;__file__='/tmp/pip-install-Qd3K08/watchdog/setup.py';f=getattr(tokenize, 'open', open)(__file__);code=f.read().replace('\r\n', '\n');f.close();exec(compile(code, __file__, 'exec'))" bdist_wheel -d /tmp/pip-wheel-0AHpMe --python-tag cp27:
usage: -c [global_opts] cmd1 [cmd1_opts] [cmd2 [cmd2_opts] ...]
or: -c --help [cmd1 cmd2 ...]
or: -c --help-commands
or: -c cmd --help
error: invalid command 'bdist_wheel'
----------------------------------------
Failed building wheel for watchdog
```
These error messages appear to have no impact on the image build, because the Python package seems to still get installed successfully afterward, just the building of a wheel package fails. Therefore, this is more of a cosmetic fix than an actual bug.
This is an addendum to https://github.com/Azure/sonic-buildimage/pull/6182.
Also upgrade pip and install more recent version of setuptools package via PyPI.
libxslt-dev and libz-dev are dependencies for lxml==4.6.1 which is required for pyangbind==0.8.1
lxml-4.6.2-cp37-cp37m-manylinux1_x86_64.whl is directly downloaded in amd64 whereas in arm this is built from lxml-4.6.2.tar.gz
Signed-off-by: Sabareesh Kumar Anandan <sanandan@marvell.com>
**- Why I did it**
To support dynamic buffer calculation.
This PR also depends on the following PRs for sub modules
- [sonic-swss: [buffermgr/bufferorch] Support dynamic buffer calculation #1338](https://github.com/Azure/sonic-swss/pull/1338)
- [sonic-swss-common: Dynamic buffer calculation #361](https://github.com/Azure/sonic-swss-common/pull/361)
- [sonic-utilities: Support dynamic buffer calculation #973](https://github.com/Azure/sonic-utilities/pull/973)
**- How I did it**
1. Introduce field `buffer_model` in `DEVICE_METADATA|localhost` to represent which buffer model is running in the system currently:
- `dynamic` for the dynamic buffer calculation model
- `traditional` for the traditional model in which the `pg_profile_lookup.ini` is used
2. Add the tables required for the feature:
- ASIC_TABLE in platform/\<vendor\>/asic_table.j2
- PERIPHERAL_TABLE in platform/\<vendor\>/peripheral_table.j2
- PORT_PERIPHERAL_TABLE on a per-platform basis in device/\<vendor\>/\<platform\>/port_peripheral_config.j2 for each platform with gearbox installed.
- DEFAULT_LOSSLESS_BUFFER_PARAMETER and LOSSLESS_TRAFFIC_PATTERN in files/build_templates/buffers_config.j2
- Add lossless PGs (3-4) for each port in files/build_templates/buffers_config.j2
3. Copy the newly introduced j2 files into the image and rendering them when the system starts
4. Update the CLI options for buffermgrd so that it can start with dynamic mode
5. Fetches the ASIC vendor name in orchagent:
- fetch the vendor name when creates the docker and pass it as a docker environment variable
- `buffermgrd` can use this passed-in variable
6. Clear buffer related tables from STATE_DB when swss docker starts
7. Update the src/sonic-config-engine/tests/sample_output/buffers-dell6100.json according to the buffer_config.j2
8. Remove buffer pool sizes for ingress pools and egress_lossy_pool
Update the buffer settings for dynamic buffer calculation
python2 is end of life and SONiC is going to support python3. This PR is going to support:
1. Mellanox SONiC platform API python3 support
2. Install both python2 and python3 verson of Mellanox SONiC platform API or pmon and host side
ntp-systemd-wrapper file from files/image_config/ntp was not getting picked up. Added a line on sonic_debian_extension.j2 to copy over the file from files/image_config/ntp after installing the debian package.
Signed-off-by: Prabhu Sreenivasan <prabhu.sreenivasan@broadcom.com>
- Allow platform specific reboot script to be called after crash kernel has
finished copying the kernel vmcore
- Disable pcie advanced features when running crash kernel. This improves
reliability of the crash kernel to successfully create a vmcore and also
reboot
- Allow crash kernel to reboot if a panic is seen while it is generating a
vmcore
- Fix crash kernel to use the SONiC specific /usr/local/bin/reboot script
instead of the Linux reboot command /sbin/reboot
- Use sonic_platform as the kernel command line parameter to pass platform identifier string
Signed-off-by: Rajendra Dendukuri <rajendra.dendukuri@broadcom.com>
The service crash when the platform boots due to missing waits.
/usr/bin/database.sh tries to operate on a missing socket and fails.
We now wait for the chassis database to be ready the same way we do database.
Barefoot platform vendors' sonic_platform packages import the Python 'thrift' library. Previously, our custom-built package was being installed in the PMon container and host OS. However, we are only building a Python 2 version of that package, which was only intended for use with saithrift.
Fixes#6077
Under certain conditions, the sFlow service can start before
interface configurations are sucessfully applied. This will
cause hsflowd to get a socket error.
This fix ensures all interface configurations are successfully
applied before the sFlow service (hsflowd) starts.
During testing we saw this error from hsflowd if interface configs were not successfully applied before hsflowd started.
ERR sflow#hsflowd: socket sendto error: Network is unreachable
no FLOW samples can be seen. This can be consistently reproducible if you force sFlow service to start before interface-config.service.
Signed-off-by: Garrick He <garrick_he@dell.com>
Submodule updates include the following commits:
* src/sonic-utilities 9dc58ea...f9eb739 (18):
> Remove unnecessary calls to str.encode() now that the package is Python 3; Fix deprecation warning (#1260)
> [generate_dump] Ignoring file/directory not found Errors (#1201)
> Fixed porstat rate and util issues (#1140)
> fix error: interface counters is mismatch after warm-reboot (#1099)
> Remove unnecessary calls to str.decode() now that the package is Python 3 (#1255)
> [acl-loader] Make list sorting compliant with Python 3 (#1257)
> Replace hard-coded fast-reboot with variable. And some typo corrections (#1254)
> [configlet][portconfig] Remove calls to dict.has_key() which is not available in Python 3 (#1247)
> Remove unnecessary conversions to list() and calls to dict.keys() (#1243)
> Clean up LGTM alerts (#1239)
> Add 'requests' as install dependency in setup.py (#1240)
> Convert to Python 3 (#1128)
> Fix mock SonicV2Connector in python3: use decode_responses mode so caller code will be the same as python2 (#1238)
> [tests] Do not trim from PATH if we did not append to it; Clean up/fix shebangs in scripts (#1233)
> Updates to bgp config and show commands with BGP_INTERNAL_NEIGHBOR table (#1224)
> [cli]: NAT show commands newline issue after migrated to Python3 (#1204)
> [doc]: Update Command-Reference.md (#1231)
> Added 'import sys' in feature.py file (#1232)
* src/sonic-py-swsssdk 9d9f0c6...1664be9 (2):
> Fix: no need to decode() after redis client scan, so it will work for both python2 and python3 (#96)
> FieldValueMap `contains`(`in`) will also work when migrated to libswsscommon(C++ with SWIG wrapper) (#94)
- Also fix Python 3-related issues:
- Use integer (floor) division in config_samples.py (sonic-config-engine)
- Replace print statement with print function in eeprom.py plugin for x86_64-kvm_x86_64-r0 platform
- Update all platform plugins to be compatible with both Python 2 and Python 3
- Remove shebangs from plugins files which are not intended to be executable
- Replace tabs with spaces in Python plugin files and fix alignment, because Python 3 is more strict
- Remove trailing whitespace from plugins files
Added new flag value 'always_enabled' for the state and auto-restart field of feature table
init_cfg.json is updated to initialize state field of database/swss/syncd/teamd feature and auto-restart field of database feature
as always_enabled
Once the state/auto-restart value is initialized as "always_enabled" it is immutable and cannot be change via feature config commands. (config feature..) PR#Azure/sonic-utilities#1271
hostcfgd will not take any action if state field value is 'always_enabled'
Since we have always_enabled field for auto-restart updated supervisor-proc-exit-listener
not to have special check for database and always rely on value from Feature table.
- Why I did it
Add reboot history to State db so that can be used telemetry service
- How I did it
Split the process-reboot-cause service to determine-reboot-cause and process-reboot-cause
determine-reboot-cause to determine the reboot cause
process-reboot-cause to parse the reboot cause files and put the reboot history to state db
Moved to sonic-host-service* packages
- How to verify it
Performed unit test and tested on DUT
Summary: Move teamd functions to a new service script
Motivation: To segregate teamd functions in one common place. fast-reboot script calls teamd functions that should ideally be replaced by a simple call to a service script.
Changes: New teamd service script and path modification from /usr/bin/teamd.sh to /usr/local/bin/teamd.sh
fast-reboot script (in sonic-utilities) modification (to use new teamd.sh to stop teamd) should follow soon after this change.
Verification: VS image tests.
Signed-off-by: Vaibhav Hemant Dixit <vaibhav.dixit@microsoft.com>
Co-authored-by: heidi.ou@alibaba-inc.com <heidi.ou@alibaba-inc.com>
Co-authored-by: Ying Xie <ying.xie@microsoft.com>
This change introduces PDDF which is described here: https://github.com/Azure/SONiC/pull/536
Most of the platform bring up effort goes in developing the platform device drivers, SONiC platform APIs and validating them. Typically each platform vendor writes their own drivers and platform APIs which is very tailor made to that platform. This involves writing code, building, installing it on the target platform devices and testing. Many of the details of the platform are hard coded into these drivers, from the HW spec. They go through this cycle repetitively till everything works fine, and is validated before upstreaming the code.
PDDF aims to make this platform driver and platform APIs development process much simpler by providing a data driven development framework. This is enabled by:
JSON descriptor files for platform data
Generic data-driven drivers for various devices
Generic SONiC platform APIs
Vendor specific extensions for customisation and extensibility
Signed-off-by: Fuzail Khan <fuzail.khan@broadcom.com>
* Remove 'backend' from device type strings so that backend devices ('BackEndToRRouter' and 'BackEndLeafRouter') are given the same cable lengths as regular device types.
Signed-off-by: Lawrence Lee <lawlee@microsoft.com>
Treat devices that are ToRRouters (ToRRouters and BackEndToRRouters) the same when rendering templates
Except for BackEndToRRouters belonging to a storage cluster, since these devices have extra sub-interfaces created
Treat devices that are LeafRouters (LeafRouters and BackEndLeafRouters) the same when rendering templates
Signed-off-by: Lawrence Lee <lawlee@microsoft.com>