1. add the console port in install.conf
2. update the ag9032v2a configuration file
3. add the default_sku in ag9032v2a
Signed-off-by: hans-tseng <hans.tseng@deltaww.com>
Issue Overview
shutdown flow
For any shutdown flow, which means all dockers are stopped in order, pmon docker stops after syncd docker has stopped, causing pmon docker fail to release sx_core resources and leaving sx_core in a bad state. The related logs are like the following:
INFO syncd.sh[23597]: modprobe: FATAL: Module sx_core is in use.
INFO syncd.sh[23597]: Unloading sx_core[FAILED]
INFO syncd.sh[23597]: rmmod: ERROR: Module sx_core is in use
config reload & service swss.restart
In the flows like "config reload" and "service swss restart", the failure cause further consequences:
sx_core initialization error with error message like "sx_core: create EMAD sdq 0 failed. err: -16"
syncd fails to execute the create switch api with error message "syncd_main: Runtime error: :- processEvent: failed to execute api: create, key: SAI_OBJECT_TYPE_SWITCH:oid:0x21000000000000, status: SAI_STATUS_FAILURE"
swss fails to call SAI API "SAI_SWITCH_ATTR_INIT_SWITCH", which causes orchagent to restart. This will introduce an extra 1 or 2 minutes for the system to be available, failing related test cases.
reboot, warm-reboot & fast-reboot
In the reboot flows including "reboot", "fast-reboot" and "warm-reboot" this failure doesn't have further negative effects since the system has already rebooted. In addition, "warm-reboot" requires the system to be shutdown as soon as possible to meet the GR time restriction of both BGP and LACP. "fast-reboot" also requires to meet the GR time restriction of BGP which is longer than LACP. In this sense, any unnecessary steps should be avoided. It's better to keep those flows untouched.
summary
To summarize, we have to come up with a way to ensure:
shutdown pmon docker ahead of syncd for "config reload" or "service swss restart" flow;
don't shutdown pmon docker ahead of syncd for "fast-reboot" or "warm-reboot" flow in order to save time.
for "reboot" flow, either order is acceptable.
Solution
To solve the issue, pmon shoud be stopped ahead of syncd stopped for all flows except for the warm-reboot.
- How I did it
To stop pmon ahead of syncd stopped. This is done in /usr/local/bin/syncd.sh::stop() and for all shutdown sequence.
Now pmon stops ahead of syncd so there must be a way in which pmon can start after syncd started. Another point that should be taken consideration is that pmon starting should be deferred so that services which have the logic of graceful restart in fast-reboot and warm-reboot have sufficient CPU cycles to meet their deadline.
This is done by add "syncd.service" as "After" to pmon.service and startin /usr/local/bin/syncd.sh::wait()
To start pmon automatically after syncd started.
* Remove the divide by 4 operation to the under the hood SAI
This is to avoid the need and thus the confusion for application program to know
the mmu internal architecture
This change must have support from SAI change to reach the correct
config
Signed-off-by: Wenda <wenni@microsoft.com>
* Relegate the divide by 4 operation to the under the hood SAI for egress
lossless pool
Extend to 7060 and 6100
Signed-off-by: Wenda <wenni@microsoft.com>
* Add more TH/TH2 hwskus
Signed-off-by: Wenda Ni <wenni@microsoft.com>
* Update config test
Signed-off-by: Wenda Ni <wenni@microsoft.com>
* Add TH2 ingress lossy profile
Signed-off-by: Wenda Ni <wenni@microsoft.com>
* Move the divide by 4 operation to SAI internal
Signed-off-by: Wenda Ni <wenni@microsoft.com>
* [bcm SAI] Upgrade Broadcom SAI to version 3.5.3.1-15
- Broadcom SAI 3.5 GA release 20190924.
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
slave.mk: add SONIC_PLATFORM_API_PY2 as dependency of host
sonic_debian_extension.j2: install sonic_daemon_base and Mellanox-specific sonic_platform on host
mlnx-platform-api.mk: export mlnx_platform_api_py2_wheel_path for sonic_debian_extension.j2
sonic-daemon-base.mk: export daemon_base_py2_wheel_path for sonic_debian_extension.j2
daemon_base.py: hind unnecessary dependency of swss_common on host
Orchagent is crashing on the latest SONiC images. Issue #458
is raised to track the problem. Dynamic port breakout
commit 6f40933d3d introduced
this regression. One of the recommendation that we received
was to disable the loopback and mgmt ports in bcm config.
It was helpful in fixing the issue but not the ideal solution.
It works on qfx5210 as the loopback and management configurations
are not applicable.
While the orchagent crash is being debugged, we need this commit
to fix the issue in qfx5210 platform. This patch can be reversed
once the correct fix for the orchagent is identified.
Signed-off-by: Ciju Rajan K <crajank@juniper.net>
* add config.bcm for hlx
* modify config.bcm path for hlx
* Delete hx4-cel-hbtn-48x1G+4x10G.config.bcm
* add config.bcm and path
* update led for cxp
* Add new device data for dx010
* [SNMP] management VRF SNMP support
This commit adds SNMP support for Management VRF using l3mdev.
The patch included provides VRF support, there is no single
"listendevice" configuration, rather multiple agentaddress
config options can each have their own "interface" to bind to
using "ip%interface". The snmpd.conf file is accordingly
generated using the snmp.yml file and redis database info.
Adding below the comments of SNMP patch 1376
--------------------------------------------
Since the Linux kernel added support for Virtual Routing
and Forwarding (VRF) in version 4.3
(Note: these won't compile on non-linux platforms)
https://www.kernel.org/doc/Documentation/networking/vrf.txt
Linux users could not use snmpd in its current form to
bind specific listening IP addresses to specific VRF
devices. A simplified description of a VRF inteface
is an interface that is a master (a container of sorts)
that collects a set of physicalinterfaces to form a
routing table.
This set of two patches (one for V5-7-patches and one
for V5-8-patches branches) is almost identical to patch
single "listendevice" configuration. Rather, multiple
agentAddress config options can each have their own
"interface" to bind to using the <ip>%<interface>
syntax.</interface></ip>
-------------------------------------------
Signed-off-by: Harish Venkatraman <harish_venkatraman@dell.com>
Commits on Sep 10, 2019
[config] Add commands to remove BGP neighbor configuration (#625) da5cc8c
Commits on Sep 12, 2019
[config] Reset failed status of all SONiC services, whether or not th… b943d67
Commits on Sep 13, 2019
[warm-reboot]: Do not clean up mirror session state database (#639) cbcdc82
Commits on Sep 17, 2019
Add SSD Health CLI utility (#587) 065414a
Fixed config Asym PFC CLI. (#632) c1c53f5
Signed-off-by: Nazarii Hnydyn <nazariig@mellanox.com>
Commits on Aug 15, 2019
[sonic_sfp] Fix global name about sfp module is not defined (#53) 04014b6
Commits on Aug 20, 2019
[xcvrd] Fix crashing due to missing fields of some module types (#54) c011c73
Remove duplicated sonic_eeprom and create symlink (#55) 087593e
Commits on Sep 10, 2019
[sfp_base] Raise exceptions (previously was incorrectly returning the… c21507e
Added new API to interact with the platform components (#60) 33b037d
Signed-off-by: Nazarii Hnydyn <nazariig@mellanox.com>
This commit adds NTP support for management VRF using L3mdev. Config vrf add
mgmt will enable management VRF, enslave the eth0 device to the master device
mgmt, stop ntp service in default, restart interfaces-configs and restart ntp
service in mgmt-vrf context. Requirement and design are covered in mgmt vrf
design document.
Signed-off-by: Harish Venkatraman <harish_venkatraman@dell.com>
Introduce a new "sflow" container (if ENABLE_SFLOW is set). The new docker will include:
hsflowd : host-sflow based daemon is the sFlow agent
psample : Built from libpsample repository. Useful in debugging sampled packets/groups.
sflowtool : Locally dump sflow samples (e.g. with a in-unit collector)
In case of SONiC-VS, enable psample & act_sample kernel modules.
VS' syncd needs iproute2=4.20.0-2~bpo9+1 & libcap2-bin=1:2.25-1 to support tc-sample
tc-syncd is provided as a convenience tool for debugging (e.g. tc-syncd filter show ...)