Add a patch in ifupdown2 such that if DHCP is used for an interface, and
the policy setting sets dhcp-wait to no (meaning don't wait for dhclient
to acquire an IP address), then don't check to see if the interface has
a new IP address, since dhclient will still be working.
Fixes#8512.
Signed-off-by: Saikrishna Arcot <sarcot@microsoft.com>
This change introduces 3 columns in the port_config.ini file.
These are coreId, corePortId and numVoq.
The ports for inband and recirc were also renamed properly.
*To run VNET route consistency check periodically.
*For any failure, the monit will raise alert based on return code.
Signed-off-by: Volodymyr Samotiy <volodymyrs@nvidia.com>
Why I did it
Update sonic-utilities submodule to include below commits:
29f4a16 Global and Interface commands for IPv6 Link local address enhancements (#1159)
a99d56d Improve config error handling on version_info (#1760)
5002745 Load the database global_db. (#1752)
Signed-off-by: Suvarna Meenakshi <sumeenak@microsoft.com>
Enable fib_multipath_use_neigh for v4
https://www.kernel.org/doc/Documentation/networking/ip-sysctl.txt
Why I did:
This is helpful if the neighbor are not directly connected then Kernel forward to unreachable neighbor option. With this option forwarding using neighbor state to be valid.
For gearbox support on arista_7280cr3mk, the following commit in sonic-sairedis is needed:
2021-07-21 c20321c Kamil Cudnik: [meta] Allow objects with the same key exist on different switches (#865)
Fix for sonic-cfggen exception during platform string read during fresh install and start of sonic in multi asic, /var/run/redisX/ is created after database docker is started.
Why I did it
Support Nokia ixr7250E IMM and Supervisor cards
How I did it
Added modules x86_64-nokia_ixr7250e_sup-r0 and x86_64-nokia_ixr7250e_36x400g-r0 ../device/nokia directory.
Modified the platform/broadcom/one-image.mk to include NOKIA_IXR7250_PLATFORM_MODULE
Modified the platform/broadcom/rule.mk to include the platform-module-nokia.mk
Why I did it
The SFP1 port was disabled in the default configuration.
How I did it
This commit enables the 10G front port for usage.
This was done using a DX030 together with an Arista switch using bcmsh and phy diag xe0 dsc to figure out what lane mappings make sense.
Validated on Celestica Seastone2 DX030.
How to verify it
Own a Celestica DX030
Connect the front SFP1 port to something.
It works :-)
You can do tcpdump -i Ethernet128 -n and you will see both incoming and outgoing LLDP.
Update SDK\FW version to 4.4.3320\2008.3324. This version contains:
New Features:
* Add support for Fast Boot for SN3800
Bug Fixing:
* In some cases, when the total number of allocations exceeds the resource limit, an error can occur due to incorrect resource release procedure. This issue is most likely to affect the following resources: flow counters, ACL actions, PBS, WJH filter, Tunnels, ECMP containers, MC (L2 &L3)
* On Spectrum systems, when using Async Router API with IPV6, an error message in the log regarding failing to remove ECMP container may show up. This error is not functional and can be safely ignored.
* On Spectrum-2 systems and above, when using warm boot, setting max_bridge_num to a value greater than 1968 will cause an error and potential crash.
* Some Molex cables do not support speed after reboot
Signed-off-by: Dror Prital <drorp@nvidia.com>
Co-authored-by: Zhi Yuan (Carl) Zhao <zyzhao@arista.com>
Why I did it
To support dynamic port breakout Broadcom configurations on Arista platforms.
How I did it
Updated platform.json for platforms and added new hwsku, Broadcom config, and hwsku.json for dynamic port breakout usage.
The name of the new hwsku name used is very similar to the platform name (platform x86_64-arista_7050_qx32s hwsku Arista-7050QX-32S) as the flex hwsku is meant to be the default in the future.
How to verify it
Boot up device with the new hwsku, interfaces are up.
Change hwsku.json with new default breakout mode and reload device, breakout will have successfully been applied.
with state of tdport from previous warm-reboot.
In case LAG was down before reboot, lacp->wr is not cleared.
In lacp_event_watch_port_flush_data we incremented nr_of_tdports and add
tdport to lacp->wr.state. In case lacp->wr.state already had this tdport
we do not set new state for tdport but appened a new item in
lacp->wr.state. In case we preformed warm-reboot and PortChannel member
was down, after reboot PortChannel member became up next warm-reboot
will initialize teamd with PortChannel member in down state.
Fix this issue by calling stop_wr_mode() when LAG was down. This was probably intended but missed.
#### Why I did it
To fix an issue seen in warm-reboot-sad test cases.
#### How I did it
I fixed it in SONiC libteam patch that adds warm-reboot support. Details in commit description.
#### How to verify it
Run warm-reboot-sad test on t0-56 topology.
#### Why I did it
Use a predefined variable to get vendor information when the swss docker container is created
#### How I did it
Use `{{ sonic_asic_platform }}` instead of `$SONIC_CFGGEN -y /etc/sonic/sonic_version.yml -v asic_type`
#### How to verify it
Manually test.
#### Why I did it
The values of the syseeprom were not valid
#### How I did it
I took the correct hexdump values from a real switch and created this hex file again
#### How to verify it
decode-syseeprom will display the new values
If branch exist already, today FRR build fails. Branch may exist on rebuild.
With this PR, we will Checkout branch gracefully if branch exists already.
Signed-off-by: Praveen Chaudhary<pchaudhary@linkedin.com>
Master/202012 image size grew quite a bit. 3.7G harddrive can no longer hold one image and safely upgrade to another image. Every bit of harddrive space is precious to save now.
Also sh syntax seemingly changed, [ condition ] && action was a legit syntax in 201911 branch but it is an error when condition not met with 202012 or later images. Change the syntax to if statement to avoid the issue.
Signed-off-by: Ying Xie ying.xie@microsoft.com
Deliver sfputil support for sfputil show eeprom and sfputil reset along with some component test case fixes
Co-authored-by: Carl Keene <keene@nokia.com>
Fix#7968
Issue is detected on SONiC.20201231.11
In test_static_route.py::test_static_route_ecmp static routes are configured, but neighbors are not resolved after config reload even after 10 minutes.
It looks like the arp_update script is starting to ping when Vlan1000 is not fully configured.
When issue is reproduced, stuck ping6 process is observed in swss container :
USER PID %CPU %MEM VSZ RSS TTY STAT START TIME COMMAND
root 180 0.1 0.0 6296 1272 pts/0 S 17:03 0:03 ping6 -I Vlan1000 -n -q -i 0 -c 1 -W 0 ff02::1
And when arp_update script successfully resolves neighbors, we observe sleep 300 instead of ping process
When using dpkg with the --root flag to install a deb package in a
chroot, dpkg checks to see if the users and groups specified in the
/var/lib/dpkg/statoverride file are valid. The problem is, it checks
against the host system's /etc/passwd and /etc/group files, instead of
/etc/passwd and /etc/group inside the chroot.
In the slave image for Buster, cron appears to have been automatically
installed, and so the crontab group existed. This doesn't appear to be
true for Bullseye, so explicitly install it. This makes sure that the
crontab group exists on the slave image itself.
Also install the mock python 3 package, this is needed by some test.
Signed-off-by: Saikrishna Arcot <sarcot@microsoft.com>
In version 3.0.0, If a broadcast address is specified in
/etc/network/interfaces, then when ifup is run, it will fail with an
error saying `'str' object has no attribute 'packed'`. This appears to
be because it expects all attributes for an interface to be "packable"
into a compact binary representation. However, it doesn't actually
convert the broadcast address into an IPNetwork object (other addresses
are handled).
Therefore, convert the broadcast address it reads in from a str to an
IPNetwork object.
Also explicitly specify the scope of the loopback address in
/etc/network/interfaces as host scope. Otherwise, it will get added as
global scope by default. As part of this, use JSON to parse ip's output
instead of text, for robustness.
Signed-off-by: Saikrishna Arcot <sarcot@microsoft.com>
The start template script that this value is used in will determine what
network namespace to use, and will add --net=host if it needs to run in
the host namespace.
With Docker 20.10, if --net=host is specified twice in docker run, then
it errors out. Therefore, remove the explicit --net=host in the run
options setting and let the start template script specify it.
Signed-off-by: Saikrishna Arcot <sarcot@microsoft.com>
With a Bullseye base image, and PTF being based on Stretch, if there are
autogenerated files that are reused from the Bullseye build for Stretch,
then autoconf-based packages will fail. This is because the default set
of CFLAGS that dpkg passes in includes `-ffile-prefix-map=`, which is
not a supported flag with the GCC in Stretch. Then, when running `make
clean` in a Stretch environment, make will try to regenerate the
autoconf-based files with the cached set of CFLAGS from Bullseye. This
causes an error, since that flag is unknown.
To work around this, after each build, clean up all built objects and
autogenerated files. This makes sure that it is cleaned up in the same
environment as the build environment.
Note that this issue affects just autoconf packages. For apps using just
regular Makefiles, they will probably be fine (they'll still be cleaned
up as well).
Signed-off-by: Saikrishna Arcot <sarcot@microsoft.com>
strncpy calls need to be mindful about the destination buffer size
passed in and doing an explicit null termination.
Signed-off-by: Saikrishna Arcot <sarcot@microsoft.com>
This PR for submodule update adds the following commits
ce51894 [Y-Cable] add the definition inside setup.py to include sonic_y_cable.credo as a package (#211)
Signed-off-by: vaibhav-dahiya <vdahiya@microsoft.com>
Why I did it
[DPB] BGP_NEIGHBOR yang model causing DPB errors.
How I did it
Allowed the BGP_NEIGHBOR list with just IP as the key to allow the current BGP neighbor table in the community.
How to verify it
Built the SONIC YANG models.
d8ca31c (origin/master, origin/HEAD, master) [vnet/vxlan] Add support of multiple mappers for the VxLAN tunnel (#1843)
7280e19 [orchagent][ports] Add port reference increment / decrement to lag member add / remove flows (#1825)
0217b66 [nhg]: Add support for weight in nexthop group member. (#1853)
df96059 VOQ: Nexthop for remote VOQ LC should be created on inband OIF. (#1823)
8f7ea14 Code changes to support IPv6 Link local enhancements (#1463)
8674b3c Open record file in append mode (#1845)
Signed-off-by: Andriy Yurkiv <ayurkiv@nvidia.com>
Why I did it
Support to build armhf/arm64 platforms on arm based system without qemu simulator.
When building the armhf/arm64 on arm based system, it is not necessary to use qemu simulator.
How I did it
Build armhf on armhf system, or build arm64 on arm64 system, by default, qemu simulator will not be used.
When building armhf on arm64, and you have enabled armhf docker, then it will build images without simulator automatically. It is based how the docker service is run.
Docker base image change:
For amd64, change from debian:to amd64/debian:
For arm64, change from multiarch/debian-debootstrap:arm64- to arm64v8/debian:
For armhf, change from multiarch/debian-debootstrap:armhf- to arm32v7/debian:
See https://github.com/docker-library/official-images#architectures-other-than-amd64
The mapping relations:
arm32v6 --- armel
arm32v7 --- armhf
arm64v8 --- arm64
Docker image armhf deprecated info: https://hub.docker.com/r/armhf/debian, using arm32v7 instead.
* add hwsku.json for the Nokia-7215
* added required default_brkout_mode to hwsku as its not optional
* remove tabs from the file so spacing consistent
Co-authored-by: Carl Keene <keene@nokia.com>
Why I did it
fix the dx010 system eeprom unavailable issue
How I did it
enable the i2c slave 30ms timeout mechanism
How to verify it
i2cstress test in DX010 iSMT controller bus
Co-authored-by: nicwu-cel <nicwu@celestica.com>
#### Why I did it
New SN410 A1 system has a different sensor layout with A0 system, needs a new sensor conf file to support it.
#### How I did it
Since the SN4410 A1 system use exactly the same sensor layout as the SN4700 A1 system, so add a symbol link linking to the SN4700 A1 sensor conf file to reuse.
#### How to verify it
Run sensor test against the SN4410 A1 system;
Run platform related regression test against the SN4410 A1 system