Meet the requirement for the MUX_CABLE table that IPv6 loopbacks have a /128 prefix
Note that this change only affects the MUX_CABLE table, all other tables continue to use the loopback address provided in minigraph.
Signed-off-by: Lawrence Lee <lawlee@microsoft.com>
Changes in this update:
37695c8 [show]: Use TCP Connection For Muxcable Commands (#1371)
8119ba2 Validations checks while creating and deleting a Portchannel (#1326)
3df267e [config] Fix Breakout mode option and BREAKOUT_CFG table check method (#1270)
9bd709b [show] Fix show arp in case with FDB entries, linked to default VLAN (#1357)
bc2d27e [generate_dump]: fix syntax error
signed-of-by: Tamer Ahmed <tamer.ahmed@microsoft.com>
Currently FRR is send Prefix with VNI information to FPMSYNCD. This PR allows FRR to send RMAC with EVPN Type5 prefix to fpmsyncd. This is a temp fix. This patch will be removed once neighorch is ready to handle the Prefix and ARP (containing RMAC) separately.
[ci]: download artifacts from master branch (#768)
Do not create fabric port if mapping is not available (#769)
[syncd] Comparison logic log also current attr value on set operation (#763)
Add fabric port test to vslib (#737)
[ci]: use sonicbld pool (#766)
[tests] Remove exit command blocking all tests to run (#765)
[vslib]: adapt macsec sai 1.7.1 (#755)
Add support for SAI_SWITCH_ATTR_AVAILABLE_IPMC_ENTRY needed by CRM (#756)
Signed-off-by: Danny Allen <daall@microsoft.com>
Fix#5026
There is a race condition between zebra server accepts connections and bgpd tries to connect. Bgpd has a chance to try to connect before zebra is ready. In this scenario, bgpd will try again after 10 seconds and operate as normal within these 10 seconds. As a consequence, whatever bgpd tries to sent to zebra will be missing in the 10 seconds. To avoid such a scenario, bgpd should start after zebra is ready to accept connections.
Avoid sonic-cfggen crashing when a server does not have a configured loopback address in the minigraph
Signed-off-by: Lawrence Lee <lawlee@microsoft.com>
When building the sonic-slave-buster docker container, the node.js package is
installed to meet the requirements of the Azure DevOPs pipleline
build. Recently this install of node.js has been failing.
This commit fixes that build break by upgrading the
sonic-slave-buster build to install version 14.x of node.js which is the
current LTS version for buster.
**- Why I did it**
On the Mellanox platform, reboot cause is fetched from some certain sysfs which is created by the hw-management service. So determine-reboot-cause service shall start after hw-management, otherwise it could fail due to the related sysfs is not available yet.
**- How I did it**
Add a patch to the hw-management service to make sure determine-reboot-cause service should start after it.
Signed-off-by: Kebo Liu <kebol@nvidia.com>
**- Why I did it**
- The thermalctld daemon on the Pmon docker requires support from the thermal manager API.
**- How I did it**
- Removed the old function for detecting a faulty fan.
- Removed the old function for detecting excess temperature.
- Implement thermal_manager APIs based on ThermalManagerBase
- Implement thermal_conditions APIs based on ThermalPolicyConditionBase
- Implement thermal_actions APIs based on ThermalPolicyActionBase
- Implement thermal_info APIs based on ThermalPolicyInfoBase
- Add thermal_policy.json
Accton util applies lsmod to check if drivers are installed.
But lsmod may return error on startup and skip module installation.
Signed-off-by: Brandon Chuang <brandon_chuang@edge-core.com>
It's been reported that accton fan monitor process keeps consuming memory after few days.
The amount of memory occupied increases in linear and never leased.
Signed-off-by: roy_lee <roy_lee@edge-core.com>
In order to build up device hierachy, PSU and module thermals are no longer child of chassis. PSU thermal belongs to PSU objects and SFP thermals belong to SFP object now. Need align this change in platform.json. Move thermal objects to correct parent device
* [warm boot finalizer] only wait for enabled components to reconcile
Define the component with its associated service. Only wait for components that have associated service enabled to reconcile during warm reboot.
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
**- Why I did it**
Earlier today we found a bug in the SONiC TSA implementation.
TSC shows incorrect output (see below) in case we have a route-map which contains TSA route-map as a prefix.
```
admin@str-s6100-acs-1:~$ TSC
Traffic Shift Check:
System Mode: Not consistent
```
The reason is that TSC implementation has too loose regexps in TSA utilities, which match wrong route-map entries:
For example, current TSC matches following
```
route-map TO_BGP_PEER_V4 permit 200
route-map TO_BGP_PEER_V6 permit 200
```
But it should match only
```
route-map TO_BGP_PEER_V4 permit 20
route-map TO_BGP_PEER_V4 deny 30
route-map TO_BGP_PEER_V6 permit 20
route-map TO_BGP_PEER_V6 deny 30
```
**- How I did it**
I fixed it by using egrep with `^` and `$` regexp markers which match begin and end of the line.
**- How to verify it**
1. Add follwing entry to FRR config:
```
str-s6100-acs-1#
str-s6100-acs-1# conf t
str-s6100-acs-1(config)# route-map TO_BGP_PEER_V4 permit 200
str-s6100-acs-1(config-route-map)# end
```
2. Use the TSC command and check output. It should show normal.
```
admin@str-s6100-acs-1:~$ TSC
Traffic Shift Check:
System Mode: Normal```
**- Why I did it**
To enable running Pytest unit tests before building the Python 3 sonic-platform-common package
**- How I did it**
- Add Python 3 sonic-config-engine package as a dependency of Python 3 sonic-platform-common package (needed for both runtime and unit tests)
- No longer disable unit tests when building Python 3 sonic-platform-common package
The only Python code in the SwSS package, restore_neighbors.py, was recently converted to Python 3 and most dependencies were updated as part of #6207. However, the SwSS makefile still listed the Python 2 version of the swsscommon package as a dependency. This caused Python 2-related packages to be installed in containers unnecessarily.
Update sonic-linux-kernel pointer to pick up new commits:
- Backport patches to increase critical threshold for ASIC and validate transceiver temperature a7c1af7c44edde90dff49d672071139043bcdb65 548e8e0be4
- [ci]: Set up CI with Azure Pipelines 548e8e0be49692050ea4071d5e9945816bc5aacc a7c1af7c44
Signed-off-by: Kebo Liu <kebol@nvidia.com>
1. Fixes the missing DPKG file for gbsyncd-vs package
2. Fixes the softlink issue on the Platform-common and ztp package
3. Fixes the PYTHNON_DEBS list is missing for DBG dockers.
Fixed swi-tools code to work with `python3`
Updated the version of swi-tools downloaded by the `sonic-slave-buster/Dockerfile.j2`
Other Dockerfiles still use the `python2` version, though swi-tools is not used within the stretch builder.
* Fix py3 version changed even version control enabled issue
* Add some comments and simplify the script
* Add the comment to explain how to get the not hooked command
- Improve random number generation during early Sonic initialization by providing SW updates to Linux entropy value.
- Improve handling of platform In-Band management port
This commit provides the following updates to the Nokia ixs7215 platform
1. The Marvell Armada-38x SOC requires SW assistance to improve the system
entropy value available early on in the Sonic boot sequence.
2. The Nokia ixs7215 platform does not have a dedicated Out-Of-Band (OOB) mgmt
port and thus requires additional logic to optionally support configuring
front panel port 48 as an In-Band mgmt port. This commit provides additional
logic to manage and maintain the operation of this In-Band mgmt port.
fix platform driver breakage due to python3 upgrade and fix load minigraph errors with config load_minigraph -y
**- How I did it**
added python3-smbus to the pmon docker template since the previous was python2 specific
fixed additional "ord" python2 specific code
fixed the jinja templates used by qos reload - the template logic required data to be parsed
**- How to verify it**
run "show platform XXX" commands and verify output
run "sudo config load_minigraph -y" and verify configuration
run "show interfaces XXX" and verify output
Co-authored-by: Carl Keene <keene@nokia.com>
Centec syncd have beend upgraded to buster, docker-syncd-centec-rpc do not need generate stretch based docker.
Co-authored-by: Xianghong Gu <xgu@centecnetworks.com>
In rare case can see that xcvrd failed due to "UnboundLocalError: local variable 'label_port' referenced before assignment"
Init "label_port" as None at the beginning of the function, to avoid the case that "label_port" not assigned.
Server IPv4 loopbacks do not always arrive with /32 prefix, which is a requirement for the MUX_CABLE table in config DB
Signed-off-by: Lawrence Lee <lawlee@microsoft.com>
Fix#119
when parallel build is enable, multiple dpkg-buildpackage
instances are running at the same time. /var/lib/dpkg is shared
by all instances and the /var/lib/dpkg/updates could be corrupted
and cause the build failure.
the fix is to use overlay fs to mount separate /var/lib/dpkg
for each dpkg-buildpackage instance so that they are not affecting
each other.
Signed-off-by: Guohan Lu <lguohan@gmail.com>
To make the peer switch hostname easily accessible from config DB. Add peer_switch field to DEVICE_METADATA table
Signed-off-by: Lawrence Lee <lawlee@microsoft.com>
* Enable telemetry for ARM64 by default
* [Centec]Upgrade Centec syncd docker to buster; libjemalloc2 have been installed in docker-base-buster, remove libjemalloc1 from docker-syncd-centec's Dockerfile.j2
Co-authored-by: Gu Xianghong <xgu@centecnetworks.com>
* Use 20 and 30 route-map entries instead of 2 and 3 for TSA
* Added support for dynamic "Allow list" default action.
Co-authored-by: Pavel Shirshov <pavel.contrib@gmail.com>
**- Why I did it**
This PR aims to monitor the running status of each container. Currently the auto-restart feature was enabled. If a critical process exited unexpected, the container will be restarted. If the container was restarted 3 times during 20 minutes, then it will not run anymore unless we cleared the flag using the command `sudo systemctl reset-failed <container_name>` manually.
**- How I did it**
We will employ Monit to monitor a script. This script will generate the expected running container list and compare it with the current running containers. If there are containers which were expected to run but were not running, then an alerting message will be written into syslog.
**- How to verify it**
I tested this feature on a lab device `str-a7050-acs-3` which has single ASIC and `str2-n3164-acs-3` which has a Multi-ASIC. First I manually stopped a container by running the command `sudo systemctl stop <container_name>`, then I checked whether there was an alerting message in the syslog.
Signed-off-by: Yong Zhao <yozhao@microsoft.com>
In scenario where upgrade gets config from minigraph, it could miss tacacs credentials as they are not in minigraph. Hence restore explicitly upon load-minigraph, if present.
- Why I did it
Upon boot, when config migration is required, the switch could load config from minigraph. The config-load from minigraph would wipe off TACACS key and disable login via TACACS, which would disable all remote user access. This change, would re-configure the TACACS if there is a saved copy available.
- How I did it
When config is loaded from minigraph, look for a TACACS credentials back up (tacacs.json) under /etc/sonic/old_config. If present, load the credentials into running config, before config-save is called.
- How to verify it
Remove /etc/sonic/config_db.json and do an image update. Upon reboot, w/o this change, you would not be able ssh in as remote user. You may login as admin and check out, "show tacacs" & "show aaa" to verify that tacacs-key is missing and login is not enabled for tacacs.
With this change applied, remove /etc/sonic/config_db.json, but save tacacs & aaa credentials as tacacs.json in /etc/sonic/. Upon reboot, you should see remote user access possible.