Removing explicit libyang plugin path settings. Libyang debian package installs the extensions in standard location.
Libyang debian package installs the extensions in standard location as per build time configuration (install prefix is set in patch/libyang.patch). If plugin directory is not set, libyang explicitly searches the plugins in LYEXT_PLUGINS_DIR which is populated during build. The plugins are installed in LYEXT_PLUGINS_DIR itself through debian package installation.
$ grep -nr LYEXT_PLUGINS_DIR src/
src/plugin_config.h.in:18:#define LYEXT_PLUGINS_DIR "@EXTENSIONS_PLUGINS_DIR_MACRO@" /**< directory with YANG extension plugins */
src/plugins.c:420: pluginsdir = LYEXT_PLUGINS_DIR;
Due to linux create hwmonN node number, N isn't fixed. So modify to use "" to let thermal.py can correct sysfs. For example, use /sys/bus/i2c/devices/55-0048/hwmon/hwmon/temp1_input to instead of /sys/bus/i2c/devices/55-0048/hwmon/hwmon4/temp1_input
This patch upgrade the kernel from version
4.9.0-9-2 (4.9.168-1+deb9u3) to 4.9.0-11-2 (4.9.189-3+deb9u2)
Co-authored-by: rajendra-dendukuri <47423477+rajendra-dendukuri@users.noreply.github.com>
Fix the issue of incorrectly skipping the convertfs hook when fast-reboot from EOS, by adding an extra kernel cmdline param "prev_os" to differentiate fast-reboot from EOS and from SONiC.
This is because we still do disk conversion for fast reboot from eos to sonic, like format the disk.
* [database] Implement the auto-restart feature for database container.
Signed-off-by: Yong Zhao <yozhao@microsoft.com>
* [database] Remove the duplicate dependency in service files. Since we
already have updategraph ---> config_setup ---> database, we do not need
explicitly add database.service in all other container service files.
Signed-off-by: Yong Zhao <yozhao@microsoft.com>
* [event listener] Reorganize the line 73 in event listener script.
Signed-off-by: Yong Zhao <yozhao@microsoft.com>
* [database] update the file sflow.service.j2 to remove the duplicate
dependency.
Signed-off-by: Yong Zhao <yozhao@microsoft.com>
* [event listener] Add comments in event listener.
Signed-off-by: Yong Zhao <yozhao@microsoft.com>
* [event listener] Update the comments in line 56.
Signed-off-by: Yong Zhao <yozhao@microsoft.com>
* [event listener] Add parentheses for if statement in line 76 in event listener.
Signed-off-by: Yong Zhao <yozhao@microsoft.com>
* [init_cfg.json] Add a new table CONTAINER_FEATURE.
Signed-off-by: Yong Zhao <yozhao@microsoft.com>
* [init_cfg.json] Update the content of table CONTAINER_FEATURE.
Signed-off-by: Yong Zhao <yozhao@microsoft.com>
* [init_cfg.json] Use the template to generate the table
CONTAINER_FEATURE.
Signed-off-by: Yong Zhao <yozhao@microsoft.com>
* [init_cfg.json] Add a new table FEATURE.
Signed-off-by: Yong Zhao <yozhao@microsoft.com>
* [init_cfg.json] Change the order of container names according to
alphabetical order.
Signed-off-by: Yong Zhao <yozhao@microsoft.com>
* [init_cfg.json] Change the dhcp_relay container name and add rest-api.
Signed-off-by: Yong Zhao <yozhao@microsoft.com>
Before the fix:
lldpcli configure ports Ethernet96 lldp portidsubtype local 'Eth1/1' description 50G|sonic1|Eth1/3/2
bash: sonic1: command not found
bash: Eth1/3/2: No such file or directory
After fix:
lldpcli configure ports Ethernet96 lldp portidsubtype local 'Eth1/1' description '50G|sonic1|Eth1/3/2'
run successfully.
Signed-off-by: Zhenggen Xu <zxu@linkedin.com>
Modify get_psu_presence(). Move read() and close() to "try: ... except IOError:" To avoid when read
port present sysfs fail. This exception will let sfputil.py to exit. So "sfputil show eeprom" can't show other port status.
Changed logic for building frr. Previously we used latest commit in the FRR_BRANCH. Now the buildsystem will use a tag to identify a commit for building. New approach will let us to update sonic-frr without corrupting building sonic-buildimage.
- Fix for Azure/sonic-buildimage#4095
- Exit status from failed make command(action) didnt reached parent target because the make command is inside the "for" loop.
- Only the exit status of the last command in the last iteration of the for loop is read by parent target.
- This is the reason why dpkg-buildpackage ignored the make error.
- Fixed the issue with help of "set -e".
- Added support for Thermal event in Last Reboot Reason "show reboot-cause" command.
- Added support for sending log message in case of thermal shutdown.
sonic NOTICE root: Shutting down due to over temperature (40 degree, 30 degree, 34 degree)
- What I did
Ported a fix from libteam master to our master.
Fixes#4070Fixes#3649
- How I did it
Applied patch jpirko/libteam@c723737 from upstream.
- How to verify it
Build image for your DUT and warm-reboot your DUT 10 times. Check that all PortChannels are up and no error messages in teamd.log
The snmp tool is required for interacting with certain type
of PDU hosts in platform PSU/power related testing. This
change is to have the snmp tool pre-built in the sonic-mgmt
docker image.
Signed-off-by: Xin Wang <xinw@mellanox.com>
* Changes in sonic-buildimage for the NAT feature
- Docker for NAT
- installing the required tools iptables and conntrack for nat
Signed-off-by: kiran.kella@broadcom.com
* Add redis-tools dependencies in the docker nat compilation
* Addressed review comments
* add natsyncd to warm-boot finalizer list
* addressed review comments
* using swsscommon.DBConnector instead of swsssdk.SonicV2Connector
* Enable NAT application in docker-sonic-vs
567191f [sairedis] Add knob to disable recording statistics API calls (#547)
8513506 Create Switch and SwitchContainer classes (#549) …
e991281 Update .gitignore (#551)
84b0eed [sairedis] Skip recording GET operations on AVAILABLE attributes (#550) …
634e4e3 [meta] Return OBJECT_IN_USE when removing port is in use (#553)
2961bd3 [syncd] Fix rpc server flag condition (#557)
as the current kdump installation is searching for grub path, and ARM arch (marvell-armhf) are dependent on uboot, these changes has to be addressed. For now skipping kdump installation on ARM
Co-authored-by: lguohan <lguohan@gmail.com>
Implement classes IpmiSensor, IpmiFru to obtain platform sensors information for Platform2.0 APIs in DellEMC Z9264 platform.
Add a new file ipmihelper.py with the implementation for IpmiSensor, IpmiFru classes.