This commit will convert the existing file system of flash drive on Arista switches from VFAT to EXT4 in the booting of SONiC. It will take the whole flash and therefore remove the recovery partition. There is a check in the script making sure that the conversion operation will not happen on a non-Arista switch or if the existing file system is not VFAT.
* Build improvements
Fix dependencies
Add configuration options
Automatically build sonic-slave
* Set default number of jobs to 1
* Auto generate target/debs directory
Signed-off-by: marian-pritsak <marianp@mellanox.com>
* Automatically remove sonic-slave container after exit
* Silence clean-logs
* Add SONIC_CLEAN_TARGETS to clean
* Use second expansion for clean dependencies
* Avoid creating empty log files
Remove log file on flush instead of writing empty string
* Put dpkg install inside lock
Use same lock as debian install targets do to avoid
race condition in dpkg installation
* Remove redirect to log from docker save
* Add .platform dependency to all and clean targets
* Remove header and footer from clean targets
* Disable messages for SONIC_CLEAN_TARGETS
* Exit with error if dpkg-buildpackage fails
* Set new location for debs in build_debian.sh
* Add recipe for docker-database
* Update redis version to 3.2.4
* Add support for p4 platform
* Add recipe for snmpd
* Add slave targets to phony and make all target default
* Remove build.sh from thrift
* Add versioning to team, nl, hiredis and initramfs
* Change sonic-slave to support snmpd build from sources
* Remove src/tenjin
* Add recipe for lldpd
* Add recipe for mpdecimal
* Remove hiredis directory on rebuild
* Add recipe for Mellanox hw management
* Remove generic image from all targets for Mellanox
* Add support for python wheels
* Add lldp and snmp dockers
* Sync docker-database to include libjemalloc
* Fix asyncsnmp variable name
* Change default build configuration
Redirect output to log files by default
Set number of jobs to nproc value
Do not print dependencies
Fix logging to print log of failed job into console
* Use docker inspect to check if sonic-slave image exists
* Use config in slave.mk directly
* Disable color output by default
* Remove sswsdk dependency from lldp and snmp dockers
* Fix comment in py wheels install targets
* Add dependency between two versions of sswsdk
* Add containers to mellanox platform
lldp, snmp and database containers
* Add recipe for team docker
* Add team docker to mellanox platform
* Encrypt password passed to build_debian.sh
* Update mellanox SAI version
Make version and revision setting only in main recipe
* Fix error handling in makefiles
As makefiles use .ONESHELL we should add -e
option to shell options in order to exit after any command fails
* Add recipe for platform monitor image
* Add platfotm monitor to mellanox targets
* Ignore submodules when building base image
This change disables DAD (IPv6's Duplicate Address Detection). DAD
protects against IP address conflicts. The way it works is that after
an address is added to an interface, the operating system uses the
Neighbor Discovery Protocol to check if any other host on the network
has the same address. If it finds a neighbor with the same address,
the address is removed from the interface.
The problem here is that the time waiting for DAD to be done is fairly
long and because that we set the host interface operating status to be
down at first, the port cannot exchange the Neighbor Discovery Protocol
and DAD will time out. The host interface is only brought up after we
have received the port admin status up notification from the kernel,
which happens only after the DAD is done or times out. This makes the
whole host interfaces bringing up procedure very slow.
This the DAD is disabled. When it is disabled, addresses are immediately
usable. Without DAD, we need to make sure that the IPv6 addresses don't
have conflicts. For now, we have two IPv6 addresses. One is assigned
manually, which prevents conflicts at first. Another one is the IPv6
link-local address. It is derived from the MAC address and thus all the
link-local addresses are the same on one box. Because link-local addresses
are not used, it will not trigger issues even if they are the same.
* Automatic fw upgrade for mlnx platform
Implement script for firmware upgrade to required version
Add firmware binary and script to ops-syncd-mlnx container
Add pciutils and usbutils to sonic-generic.bin
* Update firmware installation message
It is possible to do both upgrade and downgrade
Change "Upgrading" to "Installing compatible version"
Signed-off-by: marian-pritsak <marianp@mellanox.com>