* Add new device CIG CS6436-56P
* Delete minigraph.xml
It isn't necessary in the current system, just delete it
* Update qos.json.j2
* Update port_config.ini
Add the speed column. The cmd to show interface status as:
root@switch1:~# show interface status
Interface Lanes Speed MTU Alias Oper Admin Type Asym PFC
----------- --------------- ------- ----- ------------ ------ ------- ------ ----------
Ethernet0 8 25G 9100 Ethernet1/1 up up SFP N/A
Ethernet1 9 25G 9100 Ethernet2/1 up up SFP N/A
Ethernet2 10 25G 9100 Ethernet3/1 down down N/A N/A
Ethernet3 11 25G 9100 Ethernet4/1 down down N/A N/A
Ethernet4 12 25G 9100 Ethernet5/1 down down N/A N/A
Ethernet5 13 25G 9100 Ethernet6/1 down down N/A N/A
Ethernet6 14 25G 9100 Ethernet7/1 down down N/A N/A
Ethernet7 15 25G 9100 Ethernet8/1 down down N/A N/A
Ethernet8 16 25G 9100 Ethernet9/1 down down N/A N/A
Ethernet9 17 25G 9100 Ethernet10/1 down down N/A N/A
Ethernet10 18 25G 9100 Ethernet11/1 down down N/A N/A
Ethernet11 19 25G 9100 Ethernet12/1 down down N/A N/A
Ethernet12 20 25G 9100 Ethernet13/1 down down N/A N/A
Ethernet13 21 25G 9100 Ethernet14/1 down down N/A N/A
Ethernet14 22 25G 9100 Ethernet15/1 down down N/A N/A
Ethernet15 23 25G 9100 Ethernet16/1 down down N/A N/A
Ethernet16 32 25G 9100 Ethernet17/1 down down N/A N/A
Ethernet17 33 25G 9100 Ethernet18/1 down down N/A N/A
Ethernet18 34 25G 9100 Ethernet19/1 down down N/A N/A
Ethernet19 35 25G 9100 Ethernet20/1 down down N/A N/A
Ethernet20 40 25G 9100 Ethernet21/1 down down N/A N/A
Ethernet21 41 25G 9100 Ethernet22/1 down down N/A N/A
Ethernet22 42 25G 9100 Ethernet23/1 down down N/A N/A
Ethernet23 43 25G 9100 Ethernet24/1 down down N/A N/A
Ethernet24 48 25G 9100 Ethernet25/1 down down N/A N/A
Ethernet25 49 25G 9100 Ethernet26/1 down down N/A N/A
Ethernet26 50 25G 9100 Ethernet27/1 down down N/A N/A
Ethernet27 51 25G 9100 Ethernet28/1 down down N/A N/A
Ethernet28 56 25G 9100 Ethernet29/1 down down N/A N/A
Ethernet29 57 25G 9100 Ethernet30/1 down down N/A N/A
Ethernet30 58 25G 9100 Ethernet31/1 down down N/A N/A
Ethernet31 59 25G 9100 Ethernet32/1 down down N/A N/A
Ethernet32 64 25G 9100 Ethernet33/1 down down N/A N/A
Ethernet33 65 25G 9100 Ethernet34/1 down down N/A N/A
Ethernet34 66 25G 9100 Ethernet35/1 down down N/A N/A
Ethernet35 67 25G 9100 Ethernet36/1 down down N/A N/A
Ethernet36 68 25G 9100 Ethernet37/1 down down N/A N/A
Ethernet37 69 25G 9100 Ethernet38/1 down down N/A N/A
Ethernet38 70 25G 9100 Ethernet39/1 down down N/A N/A
Ethernet39 71 25G 9100 Ethernet40/1 down down N/A N/A
Ethernet40 72 25G 9100 Ethernet41/1 down down N/A N/A
Ethernet41 73 25G 9100 Ethernet42/1 down down N/A N/A
Ethernet42 74 25G 9100 Ethernet43/1 down down N/A N/A
Ethernet43 75 25G 9100 Ethernet44/1 down down N/A N/A
Ethernet44 76 25G 9100 Ethernet45/1 down down N/A N/A
Ethernet45 77 25G 9100 Ethernet46/1 down down N/A N/A
Ethernet46 78 25G 9100 Ethernet47/1 down down N/A N/A
Ethernet47 79 25G 9100 Ethernet48/1 down down N/A N/A
Ethernet48 84,85,86,87 100G 9100 Ethernet49/1 up up QSFP28 N/A
Ethernet49 80,81,82,83 100G 9100 Ethernet50/1 up up QSFP28 N/A
Ethernet50 92,93,94,95 100G 9100 Ethernet51/1 down down N/A N/A
Ethernet51 88,89,90,91 100G 9100 Ethernet52/1 down down N/A N/A
Ethernet52 108,109,110,111 100G 9100 Ethernet53/1 down down N/A N/A
Ethernet53 104,105,106,107 100G 9100 Ethernet54/1 down down N/A N/A
Ethernet54 116,117,118,119 100G 9100 Ethernet55/1 down down N/A N/A
Ethernet55 112,113,114,115 100G 9100 Ethernet56/1 down down N/A N/A
root@switch1:~#
Backport of
54f137c105
According to 6.4.15 of IEEE 802.1AX-2014, Figure 6-22, the state that the
port is selected moves MUX state from DETACHED to ATTACHED.
But ATTACHED state does not mean that the port can send and receive user
frames. COLLECTING_DISTRIBUTION state is the state that the port can send
and receive user frames. To move MUX state from ATTACHED to
COLLECTING_DISTRIBUTION, the partner state should be sync as well as the
port selected.
In function lacp_port_actor_update(), only INFO_STATE_SYNCHRONIZATION
should be set to the actor.state when the port is selected.
INFO_STATE_COLLECTING and INFO_STATE_DISTRIBUTING should be set to false
with ATTACHED mode and set to true when INFO_STATE_SYNCHRONIZATION of
partner.state is set.
In function lacp_port_should_be_{enabled, disabled}(), we also need to
check the INFO_STATE_SYNCHRONIZATION bit of partner.state.
Signed-off-by: Hangbin Liu <liuhangbin@gmail.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
* [dockers]: Upgrade SNMP docker to stretch build
* Removed patch-> 0003-CHANGES-BUG-2743-snmpd-crashes-when-receiving-a-GetN.patch
* update platform-common submodule
* adding PyYAML package to stretch dockerfile
* Installing redis package via pip in stretch dockerfile
* again updating platform-common submodule
* revert back the snmpd version to 5.7.3+dfsg-1.5
* upgrading the snmpd version to 5.7.3+dfsg-1.7+deb9u1 with openssl backport support
* update sonic-snmpagent submodule
* purge libdpkg-perl package in Dockerfile
* revert back the snmpd version to 5.7.3+dfsg-1.5
* minor change in series file
SONiC is a heavy writer to /var/log partition, we noticed that this
behavior causes certain flash drive to become read-only over time.
To avoid this issue, we mount /var/log parition on these devices as
tmpfs.
- Mount /var/log as tmpfs
- /var/log default size is 128M
- Adjust size according to existing var-log.ext4 file size.
- Adjust size to between 5% to 10% of total memory size.
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
* Updated Makefile infrastructure to build debug images.
As a sample, platform/broadcom/docker-orchagent-brcm.mk is updated to add a docker-orchagent-brcm-dbg.gz target.
Now "BLDENV=stretch make target/docker-orchagent-brcm-dbg.gz" will build the debug image.
This debug image can be used in any linux box to inspect core file. If your module's external dependency can be suitably mocked, you my even manually run it inside.
"docker run -it --entrypoint=/bin/bash e47a8fb8ed38"
You may map the core file path to this docker run.
* Dropped the regular binary using DBG_PACKAGES and a small name change to help readability.
* Tweaked the changes to retain the existing behavior w.r.t INSTALL_DEBUG_TOOLS=y.
When this change ('building debug docker image transparently') is extended to all dockers, this flag would become redundant. Yet, there can be some test based use cases that rely on this flag.
Until after all the dockers gets their debug images by default and we switch all use cases of this flag to use the newly built debug images, we need to maintain the existing behavior.
After warm reboot is done, we need to disable warm reboot flag and
tear down anything setup for warm reboot and persisted across.
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
sonic-sairedis:
e8cb879 Make object list deterministic when iterating (#438)
5486f97 Ignore ACL_COUNTER bytes and packets during comparison logic (#443)
b138ff9 Notify OA about exception and process only restart query events (#437)
0974a43 Set MTU value on created tap device for virtual switch (#436)
e2f50e8 Increase eth buffer size to 16k for virtual switch (#435)
79fb388 [bfn] Ged rid of ld_preload. Link against libsai only (#429)
2e47b78 Remove MAC alignment WA for Mellanox platforms. (#430)
e1354fe Add pre match to comparison logic and unittests (#423)
18a5ebb Drop FDB notifications if they contain invalid OIDs (#428)
sonic-swss-common:
8af58ad sonic-swss-common: Add vxlan macros to schema (#269)
76837bf Make class Select support batch read from selectables (#270)
4cf643e Add multiple fields hdel support (#267)
a710529 Update PFC_WD table name in CONFIG_DB (#266)
3c452c1 Update README.md (#268)
sonic-swss:
e329dbd Survive pfc watchdog storm action across warm-reboot (#794)
sonic-utilities:
6ee0aea (HEAD, origin/master, origin/HEAD) [config]: Change the order of interface commands (#504)
5ae30d2 [show vlan brief] Support 'alias' interface naming mode (#497)
bafebf9 Update neighbor advertiser (#498)
fa90083 [clear/main.py]: clear ndp command. (#450)
65f69e4 [show interface neighbor expected] Support 'alias' interface naming mode (#495)
aae39e7 updated show ipv6 interface for alias mode (#493)
170fed9 [warm-reboot] initialize warm reboot state table before warm rebooting (#492)
06cd99f Allow config shutdown and startup operations on valid PortChannel interface names (#474)
98cdebb [show ip interface] Add support for 'alias' interface naming mode (#486)
5f1de81 [show] Add serial numbers/uptime/hwinfo to 'show version' output (#488)
e78a866 [route_check] Move scripts under scripts/ directory, add to setup.py (#489)
d347527 Change PFC watchdog CONFIG_DB table name from PFC_WD_TABLE to PFC_WD (#475)
Signed-off-by: Wenda Ni <wenni@microsoft.com>
There are some platforms with less powerful CPU/hard-drive could take
longer to get ready for BGP. For these platforms, 240 seconds would be
a safer threshold.
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
When adding a lag member dynamically after system boots up, teamd
port priv change handler could re-entrant itself and causing adding
operation to fail.
While handling PORT_CHANGE event, teamd_per_port.c port priv change
handler was called, it will then call runner_lacp to add port to lag,
the later causes IFINFO_CHANGE to be notified and calls the priv change
handler again, this re-entrance would cause runner_lacp port_added to
be called again and messes up with the previous adding sequence. Then
fails the lag member adding operation.
Prevent per port priv change handler re-entrance solves the problem.
Signed-off-by: Ying Xie <ying.xie@microsoft.com>