**- What I did**
#### wheel package Makefiles
- wheel package Makefiles for sonic-yang-mgmt package.
#### libyang Python APIs:
- python APIs based on libyang
- functions to load/merge yang models and Yang data files
- function to validate data trees based on Yang models
- functions to merge yang data files/trees
- add/set/delete node in schema and data trees
- find data/schema nodes from xpath from the Yang data/schema tree in memory
- find dependencies
- dump the data tree in json/xml
#### Extension of libyang Python APIs:
-- Cropping input config based on Yang Model.
-- Translate input config based on Yang Model.
-- rev Translate input config based on Yang Model.
-- Find xpath of port, portleaf and a yang list.
-- Find if node is key of a list while deletion if yes, then delete the parent.
Signed-off-by: Praveen Chaudhary pchaudhary@linkedin.com
Signed-off-by: Ping Mao pmao@linkedin.com
* [device][accton]: Update for AS5835-54T
* [device][accton]: Update for AS5835-54T to delete its config.bcm off-loading to the self-brought up of the Broadcom SAI version, 3.5.2.3 due to SONiC not supported.
* [device][accton]: Add config.bcm for AS5835-54T
* Ran config_checker passed on our config.bcm, however, we off-loaded the needed MV2 SDK config setting to our self-brought up SAI libraries due to the compatibility of config_check among SONiC different branches.
[-] help_cli_enable=1
[-] ifp_inports_support_enable=1
[-] memlist_enable=1
[-] port_flex_enable=1
[-] reglist_enable=1
* [device][accton]: Update config.bcm for AS5835-54T based on the latest config_checker
Co-authored-by: Polly Hsu <pollyhsu2git@gmail.com>
- What I did
1. Rename the config.bcm to th2-as7816-64x25G-48x100G_row1.config.bcm,
due to that it just allow 1st row of TH2 to be breakout
2. Add port_flex_enable to support dynamic port breakout.
3. Remove the loopback port due to it would make syncd terminate.
=> The port_config.ini doesn't include the loopback ports.
When portsorch start, it would compare the ports in SDK and port_config.ini.
Portsorch would remove the loopback ports due to the loopback ports didn't been defined in port_config.ini
But the broadcom SAI doesn't support remove port for th2.
So it would return fail and syncd would terminate.
- How I did it
- How to verify it
Run with the new SONiC image and syncd would not terminate
Signed-off-by: chiourung_huang <chiourung_huang@edge-core.com>
- bug fix : Fixed an issue which the nps ko file was not loaded due to the wrong service file name
- Optimize the code to reduce changes due to the kernel upgrade
- Remove nephos ko file loaded in swss.service.j2 because it has loaded at syncd.service.j2
* Adding new BGP peer groups PEER_V4_INT and PEER_V6_INT. The internal BGP sessions
will be added to this peer group while the external BGP sessions will be added
to the exising PEER_V4 and PEER_V6 peer group.
* Check for "ASIC" keyword in the hostname to identify the internal neighbors.
* The following changes for multi-npu platforms are done
- Set the type in device_metadata for asic configuration to be same as host
- Set the admin-status of internal bgp sessions as up
Signed-off-by: Arvindsrinivasan Lakshmi Narasimhan <arlakshm@microsoft.com>
* Changes to support config-setup service for multi-npu
platforms. For Multi-npu we are not supporting as of
now config initializtion and ZTP. It will support creating
config db from minigraph or using config db from previous
file system
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
* Address Review Comments.
* Address Review comments
* Address Review Comments of using pyhton based config load_minigraph/
config save/config reload from shell scripts so that we don't duplicate
code. Also while running from shell we will skip stop/start services
done by those commands.
* Updated to use python command so no code duplication.
For detecting transceiver change events through xcvrd in DellEMC S6000, S6100 and Z9100 platforms.
- In S6000, rename 'get_transceiver_change_event' in chassis.py to 'get_change_event' and return appropriate values.
- In S6100, implement 'get_change_event' through polling method (poll interval = 1 second) in chassis.py (Transceiver insertion/removal does not generate interrupts due to a CPLD bug)
- In Z9100, implement 'get_change_event' through interrupt method using select.epoll().
* [ntp] enable/disable NTP long jump according to reboot type
- Enable NTP long jump after cold reboot.
- Disable NTP long jump after warrm/fast reboot.
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
* fix typo
* further refactoring
* use sonic-db-cli instead
lldpmgrd listens for changes to the PORT table in the CONFIG_DB and APP_DB in order to handle alias/description config change. It checks if port is up or down by looking into the oper-status for in APP_DB PORT TABLE. If it cannot find it in the App DB, it will log error.
During initializing, it is possible that there is a port change in CONFIG_DB and but the not ready in APP_DB.
The change here is to only log error in is_port_up() after port init done.
Fix is_mgmt_vrf_enabled when MGMT_VRF_CONFIG is not present the config (#885)
Changes to support acl-loader command for multi-npu platforms. (#908)
Stop/Start restapi server upon config reload (#911)
[fanshow] Add column drawer name and led status to output of show
platform(#991)
[MultiDB] use sonic-db-cli instead of redis-cli in new added codes
(#907)
[show] Add `ntpstat` output to `show ntp` (#861)
[config] Log invocation of config commands to syslog (#259)
Remove dependency on click-default-group package (#903)
[config] Add 'interface transceiver' subgroup with 'lpmode' and 'rese…'
(#904)
[show] Add 'errors' and 'rates' subcommands to 'show interfaces
count…(#900)
[config] Support load_minigraph command for multi NPU platform (#896)
[Vnet] Fix NameError for 'swsssdk' and align output (#902)