* Add Broadcom config files for Arista-7050-QX32 and Arista-7050-Q16S64 SKUs under respective directories
* Remove 'serdes_firmware_mode_xe=0x1' line from Arista 7050 Broadcom config files
* [caclmgrd] Heuristically determine whether ACL is IPv4 or IPv6, use iptables/ip6tables accordingly
* Check all rules in table until we find one with a SRC_IP
* Revert "[serial watchdog] remove serial watchdog service dependency to rc.local (#1752)"
* Revert "[service] introducing serial port watchdog service (#1743)"
* [serial watchdog] remove serial watchdog service dependency to rc.local
When restarting this service in rc.local, the dependency causes an error
in syslog. Removing the dependency to mute the error log entry.
* remove lines with empty inputs
* Fix minigraph parser issue when handling LAG related ACL table configuration
* rephrase the warning message.
* pick up swss change in https://github.com/Azure/sonic-swss/pull/494
* 524685a 2018-05-14 | Ignore bridge port id in fdb consolidated event if value is NULL (#319) (origin/201803) [Kamil Cudnik]
* be0d9c3 2018-05-23 | Merge pull request #321 from yxieca/syncd [Ying Xie]
Signed-off-by: Guohan Lu <gulv@microsoft.com>
* [rc.local] refactor platform identification code to separate function
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
* [rc.local] infrastructure to take action according to installer.conf
* [serial port watchdog] add service to watch serial port processes
Monitor serial port processes. Kill ones stuck for too long.
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
* [rc.local] start watchdog on serial port specified by installer.conf
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
* Add noise config for PortChannel & EthernetInterface in simple-sample-graph.xml
* Add noise config for PORTCHANNEL_INTERFACE in simple-sample-graph.xml
Signed-off-by: Wenda <wenni@microsoft.com>
* Add noice config for DEVICE_NEIGHBOR in t0-sample-graph.xml
Add unit test against introducing ports not existing in port_config.ini
into DEVICE_NEIGHBOR
Signed-off-by: Wenda <wenni@microsoft.com>
* DeviceInterfaceLink in minigraph.xml can contain port not existing in
port_config.ini but contraining non-zero Bandwidth attribute
Add noice config in simple-sample-graph.xml to capture the case that
such a port is leaked into config_db.json
Signed-off-by: Wenda <wenni@microsoft.com>
* Protect PORTCHANNEL from ports not existing in port_config.ini
Signed-off-by: Wenda <wenni@microsoft.com>
* Protect PORTCHANNEL_INTERFACE from portchannels containing ports not
existing in port_config.ini
Signed-off-by: Wenda <wenni@microsoft.com>
* Protect DEVICE_NEIGHBOR from ports not existing in port_config.ini
Signed-off-by: Wenda <wenni@microsoft.com>
* Add noise config Ethernet1 in DeviceInterfaceLinks in simple-sample-graph.xml as it is in PortChannel1001
Signed-off-by: Wenda <wenni@microsoft.com>
* Add noise config Ethernet1 in DeviceInterfaceLinks in simple-sample-graph.xml as it is in PortChannel1001
Signed-off-by: Wenda <wenni@microsoft.com>
* Protect PORTCHANNEL from ports not existing in port_config.ini
Signed-off-by: Wenda <wenni@microsoft.com>
* Protect PORTCHANNEL_INTERFACE from portchannels containing ports not
existing in port_config.ini
Signed-off-by: Wenda <wenni@microsoft.com>
* Protect DEVICE_NEIGHBOR from ports not existing in port_config.ini
Signed-off-by: Wenda <wenni@microsoft.com>
* Correct space in minigraph.py
Signed-off-by: Wenda <wenni@microsoft.com>
* Does not allow non-port_config.ini port to get into the port list
Signed-off-by: Wenda <wenni@microsoft.com>
* Check PORTCHANNEL against PORT list only if port_config_file exists
Signed-off-by: Wenda <wenni@microsoft.com>
* Correct format
Signed-off-by: Wenda <wenni@microsoft.com>
* print warning when a port coming from DeviceInterfaceLink is not in
port_config.ini
Signed-off-by: Wenda <wenni@microsoft.com>
* Change Ethernet1 and 2 to fortyGigE0/1 and 2,respectively
Signed-off-by: Wenda <wenni@microsoft.com>
* Change Ethernet1 and 2 to fortyGigE0/1 and 2,respectively
Signed-off-by: Wenda <wenni@microsoft.com>
* print warning when ignoring ports, portchannels, portchannel interfaces, and
device neighbors
Update t0-sample-graph.xml with interface name 'fortyGigE0/2' and the
ACL_TABLE output
Signed-off-by: Wenda <wenni@microsoft.com>
* [fast-reboot]: support encoded & gzipped minigraph in fast reboot
Signed-off-by: Guohan Lu <gulv@microsoft.com>
* add acl.json and snmp.yml into fast-reboot
Signed-off-by: Guohan Lu <gulv@microsoft.com>
I took the original patch (bebb7a0) into 201803 branch need to also
adapt the patch since we do not have commit (d423841) in 201803 branch.
Signed-off-by: Guohan Lu <gulv@microsoft.com>