Commit Graph

213 Commits

Author SHA1 Message Date
mssonicbld
b812e562c8
[minigraph] remove number of lanes check for changing speed from 400G to 100G and set speed setting before lane reconfiguration (#15721) (#16054) 2023-08-07 03:24:30 +08:00
Zhijian Li
90dc056824 Update the defination of acl table type BMCDATA and BMCDATAV6 (#15385)
Why I did it
Update the definition of acl table type BMCDATA and BMCDATAV6 in minigraph parser.

Work item tracking
Microsoft ADO (number only): 24101023
How I did it
Update the definition of acl table type BMCDATA and BMCDATAV6 in minigraph parser.

How to verify it
Ran unittest to verify this update:
2023-06-26 16:41:02 +08:00
Prince Sunny
f75116ab7a
Create default Vxlan and Vnet configs (#13409)
* Create default Vxlan and Vnet configs for ToRs with Appliance Resource type
2023-06-14 16:07:46 -07:00
abdosi
3a098cfdea
Update AclInterface and Management Interfaces parsing for multi-asic case (#14952)
* AclInterface and Management Interfaces are parsed on finding first valid node for it.
Above logic works for multi-asic scenarios where ACL Interface and Management Interfaces are present in DPG order {Host, Asicx, Asicy} but not when DPG is in {Asicx, Asicy, Host} order.
2023-06-02 16:04:14 -07:00
Guilt
a73d443c1d
[CI][doc][build] Trim src folder files trailing blanks (#15162)
- Run pre-commit tox profile to trim all trailing blanks
- Use several commits with a per-folder based strategy
  to ease their merge

Issue #15114

Signed-off-by: Guillaume Lambert <guillaume.lambert@orange.com>
2023-05-24 10:01:43 -07:00
Yaqiang Zhu
c69d71af1c
[minigraph] Add rack_mgmt_rack parse support in minigraph.py (#15064)
Why I did it
We need to store information of power shelf in config_db for SONiC MX switch. Current minigraph parser cannot parse rack_mgmt_map field.

Work item tracking
Microsoft ADO (number only): 22179645
How I did it
Add support for parsing rack_mgmt_map.
2023-05-20 09:25:21 -07:00
abdosi
b5b5883c27
[minigraph.py]: Updated Static Route Minigraph Attribute property (#14951)
What I did:
Updated Static Route Attribute in Minigraph. NGS Minigraph has define semantics of static route differently.
See below for differences:-

Microsoft ADO: 17956325

Before

<AssociatedTo>8.0.0.1/32</AssociatedTo>
<Address>192.168.1.2,192.168.2.2</Address>
<AttachTo>PortChannel40,PortChannel50</AttachTo>

Now:

<Address>8.0.0.1</Address>
<AttachTo>PortChannel40,192.168.1.2;PortChannel50,192.168.2.2</AttachTo>

Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
2023-05-19 11:49:10 -07:00
abdosi
b7d04b6bd5
[minigraph]: Enhancement to minigraph parsing for chassis/multi-asic use case (#14243)
Following changes are done:    

Added Support where if asic configuration is not present in minigraph sonic-cfggen do not error out but instead process it gracefully. 

Use Case: In Supervisor we have number of asic are define as max possible but in minigraph configuration of only valid/available asics only are present. Without this change load_minigraph fails.

Microsoft ADO: 17956325

Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
2023-05-18 10:57:16 -07:00
anamehra
ab7bcb43b7
[minigraph.py]: Enable 400G to 100G/40G speed change via minigraph for all platforms (#14736)
There are chassis-packet and Single asic platforms which support this 400G to 100G/40G speed change via config.
Enabling this feature for all platforms which can support this. Keeping it enabled for all does not affect the platforms
which do not support this feature yet.

Signed-off-by: anamehra anamehra@cisco.com
2023-05-05 13:52:40 -07:00
Zhijian Li
77728f5e36
[minigraph-parser] Support ACL interface type BmcData in minigraph parser (#14703)
* Support ACL interface type BmcData in minigraph parser

* Support ACL interface type BmcData in minigraph parser

* add unittest

* Add a global dict for storing the defination of custom acl tables
2023-04-26 16:07:38 -07:00
vdahiya12
9e2d457a42
[minigraph] add support for changing T1 ports speed from 400G to 100G and vice-versa (#14505)
Open
[minigraph] add support for changing T1 ports speed from 400G to 100G and vice-versa
#14505
vdahiya12 wants to merge 9 commits into sonic-net:master from vdahiya12:dev/vdahiya/minigraph_parser
Conversation 10
Commits 9
Checks 18
Files changed 5
Conversation
vdahiya12
@vdahiya12 vdahiya12 commented 2 weeks ago • 
On SONiC T1 cisco 8101 HwSku, the speed changes are done from 400G to 100G needs to be supported on 400G ports.
To enable this, along with speed change the port lanes need to be changed. This PR has the changes to update the port lanes when such speed change happens.
Basically if Banwidth in minigraph.xml intends to enable a 100G speed on a 400G port, then the appropriate lane change and speed change needs to be invoked in mingraph parser
Example if port_config.ini dicatates the speed to be 400G and minigraph has 100G speed, then this changeneeds to be accommodated

# name         lanes                                      alias   index  speed    channel
Ethernet96     1536,1537,1538,1539,1540,1541,1542,1543    etp12    12       400000     0
 <DeviceLinkBase>
        <ElementType>DeviceInterfaceLink</ElementType>
        <EndDevice>ARISTA01T2</EndDevice>
        <EndPort>Ethernet1</EndPort>
        <StartDevice>Device-8101-01</StartDevice>
        <StartPort>etp12</StartPort>
        <Bandwidth>100000</Bandwidth>
      </DeviceLinkBase>
These platforms today have 400g port with 8 serdes lines, and 100g will operate with 4 serdes lane. When the port speed changes from 400G to 100G the first 4 lanes will be used for 100G port.

Signed-off-by: vaibhav-dahiya <vdahiya@microsoft.com>
2023-04-19 01:23:19 -07:00
Neetha John
ab097788d5
[qos] Update RDMA-CENTRIC lossy profile to use static threshold for Th devices (#14372)
Why I did it
For better accounting purposes, updating the ingress lossy traffic profile to use static threshold. This change is only intended for Th devices using RDMA-CENTRIC profiles

How I did it
Update the buffer templates for Th devices in RDMA-CENTRIC folder to use the correct threshold

How to verify it
Verified the changes manually on a Th device.
Existing unit tests render Th template from the RDMA-CENTRIC folder. Updated the expected output to use the correct threshold
2023-03-23 09:31:06 -07:00
Marty Y. Lok
836d65d616
[EVERFLOW][ACL_ATBLE] Fix for everflow ACL_TABLE in config_db not having the routed ports when no -ASIC in the asic_port_name (#13532)
Why I did it
After the renaming of the asic_port_name in port_config.ini file (PR: #13053 ), the asic_ifname in port_config.ini is changed from '-ASIC<asic_id>' to just port. Example: 'Eth0-ASIC0' to 'Eth0'.

However, with this change a config_db generated via config load_minigraph would cause the EVERFLOW and EVERFLOWV6 tables under ACL_TABLE to not have any of non-LAG front panel interfaces. This was causing the EVERFLOW suite to fail.

How I did it
In parse_asic_external_neigbhors in minigraph.py there was a check that the asic_name.lower() (like asic0) is present in the port_alias_asic_map. However with -ASIC removed from the asic_ifname, the port_alias_asic_map would not have the asic_name and thus any non-LAG neighbor would not be included.

Fix was the ignore the asic name change as the port_alias_asic_map is already only looking for ports in just the same asic as asic_name.

How to verify it
Execute "config load_minigraph" with the mingraph which is generated by sonic-mgmt gen-minigraph script. And confirm ono-lag interface are present in the Everfloe table in the config_dbs.

Signed-off-by: mlok <marty.lok@nokia.com>
2023-03-13 10:58:32 -07:00
Arvindsrinivasan Lakshmi Narasimhan
da1526ce01
[chassis][voq] 400g to100g speed changes for chassis linecards (#13935)
On SONiC VoQ chassis, the speed changes are done from 400G to 100G needs to be supported on 400G linecards.
To enable this, along with speed change the port lanes need to be changed. This PR has the changes to update the port lanes when such speed change happens.

This PR is intended only for VoQ chassis linecards. These platforms today have 400g port with 8 serdes lines, and 100g will operate with 4 serdes lane. When the port speed changes from 400G to 100G the first 4 lanes will be used for 100G port.

Platforms which support 2x50g PAM4 or support 100G PAM4 serdes or other combinations are not handled in the PR.

Signed-off-by: Arvindsrinivasan Lakshmi Narasimhan <arlakshm@microsoft.com>
2023-02-23 21:41:58 -08:00
Saikrishna Arcot
3e316cbf24
Don't create the members@ array in config_db for PC when reading from minigraph (#13660)
Fixes #11873.

#### Why I did it

When loading from minigraph, for port channels, don't create the members@ array in config_db in the PORTCHANNEL table. This is no longer needed or used.

In addition, when adding a port channel member from the CLI, that member doesn't get added into the members@ array, resulting in a bit of inconsistency. This gets rid of that inconsistency.
2023-02-23 14:49:51 -08:00
judyjoseph
bc2cb46ec5
Voq Chassis: Add the Recirc ports to the INTERFACES table to make it routed intf (#13779)
* VOQ: Add the Recirc ports to the INTERFACES table to make it routed intf

* Add a test to cover Recir port generation in INTERFACE table
2023-02-21 11:35:38 -08:00
bingwang-ms
b03a65f331
Support both port name and alias in ACL table AttachTo attribute (#13444)
Why I did it
This PR is an enhancement of PR #13105
Because the input string of AttachTo for ACL table can appear in both port name group and port alias group, I added a logic to determine whether the string should be port name or port alias

If all the input strings belong to port name group, then we treat all of them as port name
If all the input strings belong to port alias, then we treat all of them as port alias
If all the input string belongs to both port alias group and port name group, we prefer port alias. The behavior is as before.
How I did it
Walk through all port names/alias in the input to make a decision.

How to verify it
Verified by adding UT.
2023-01-20 10:11:39 -08:00
bingwang-ms
22fcc760c4
[minigraph]: Support port name in ACL table AttachTo attribute (#13105)
Why I did it
This PR is to update minigraph.py to support both port alias and port name as input of AttachTo attribute of ACL table.
Before this change, only port alias is supported.

How I did it
Add a global variable to store port names
Search both port names and port alias wheh parsing the value of AttachTo.

How to verify it
Verified by a new unit test case test_minigraph_acl_attach_to_ports
Verified by copying the new minigraph.py to a testbed and run conflg load_minigraph.
2023-01-12 23:54:25 -08:00
abdosi
e1ba683635
Add lacp_key as auto in portchannel configuration when parsing minigraph (#12694)
Add lacp_key as auto in portchannel configuration when parsing minigraph
Needed as mention in issue: https://github.com/sonic-net/sonic-buildimage/issues/4009
2022-11-15 09:42:12 -08:00
isabelmsft
db7459787c
Add yang_config_validation to minigraph.py (#12504) 2022-10-27 20:57:06 -05:00
Neetha John
615f277701
[minigraph] Remove SLB and bgp monitor peers for storage backend (#12251)
Signed-off-by: Neetha John nejo@microsoft.com

Why I did it
slb and bgp mon peers are not needed for storage backend. These neighbor are present in the minigraph.

How I did it
After minigraph parsing, remove these neighbors if it is a storage backend device

How to verify it
Unit tests
Verified on the device that once these tables are removed, these peers don't show up in "show runningconfig bgp" output
2022-10-07 09:37:53 -07:00
jcaiMR
b34d94be1f
yang model table DEVICE_NEIGHBOR_METADATA creation (#11894)
* yang mode support for neighbor metadata

* add description in leaf node

* modify description
2022-09-13 10:07:17 +08:00
bingwang-ms
485edbfd67
Disable tunnel qos remap on KVM (#11735) 2022-08-16 07:50:04 +08:00
arlakshm
743625c2b4
[Chassis] parse 400g zr port config from minigraph (#11616)
Signed-off-by: Arvindsrinivasan Lakshmi Narasimhan arlakshm@microsoft.com

Why I did it
Generate the port configuration required 400G ZR port from minigraph.

How I did it
Add parse logic to get tx_power and laser_freq from LinkMetadata section of the minigraph.
Add UT for packet-chassis and voq chassis

How to verify it
UT
Signed-off-by: Arvindsrinivasan Lakshmi Narasimhan <arlakshm@microsoft.com>
2022-08-12 11:55:18 -07:00
bingwang-ms
5c0577d7d2
Automatically enable tunnel_qos_remap on T1 and T0 in DualToR deployment (#11508)
Why I did it
This PR is to backport PR #11056 and PR #11045 into master branch.
This PR is to enable tunnel_qos_remap on T1 and T0 in DualToR deployment.
On T1, we check the property DownstreamRedundancyTypes. On T0, we check the property RedundancyType.
tunnel_qos_remap is set to enabled if gemini is in DownstreamRedundancyTypes (on T1) or RedundancyType (on T0).

How I did it
The change is implemented in minigraph.py.

How to verify it
Verified by test_minigraph_case.py and 'test_j2files.py`.
2022-07-25 11:00:00 -07:00
Ying Xie
ae2f37e658
[minigraph] allow LibraPeeringLink to be dualtor indication as well (#11492)
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
2022-07-21 08:24:39 -07:00
abdosi
1e387f1189
Added Support for deployment_id parsing for Device Asic metadata (#11454)
What I did:
Added Support for deployment_id parsing for Device Asic metadata.

Why I did:-
Deployment Id is used in BGP docker for FRR template generation. For multi-asic platforms running in namespace without deployment id as key in DEVICE_METADATA FRR template generation fails. This change is needed after this #10154 where if deployment_id is none we don't update DEVICE_METADA dictionary.

How I verify:-
Added unit-test.
2022-07-18 07:10:13 -07:00
Neetha John
23308a345b
Minigraph parser changes to select mmu profiles based on SonicQosProfile attribute (#11429)
Signed-off-by: Neetha John <nejo@microsoft.com>

Why I did it
There is a need to select different mmu profiles based on deployment type

How I did it
There will be separate subfolders (RDMA-CENTRIC, TCP-CENTRIC, BALANCED) in each hwsku folder which contains deployment specific mmu and qos settings. SonicQosProfile attribute in the minigraph will be used to determine which settings to use. If that attribute is not present, the default settings that exist in the hwsku folder will be used
2022-07-13 15:25:28 -07:00
geogchen
5171589f4d
Add support to generate /e/n/i when there are multiple MGMT_INTERFACE (#11368)
Why I did it
Currently interfaces.j2 hardcodes to eth0 even when there are multiple interfaces in MGMT_INTERFACE. This change adds support to generate /e/n/i when there are multiple interfaces in MGMT_INTERFACE.

How I did it
By removing hardcoded eth0 when looping through MGMT_INTERFACE.

How to verify it
Verified through unit test.

Which release branch to backport (provide reason below if selected)
 201811
 201911
 202006
 202012
 202106
 202111
 202205
Description for the changelog
Link to config_db schema for YANG module changes
A picture of a cute animal (not mandatory but encouraged)
2022-07-12 14:55:15 -07:00
Neetha John
05ab004593
Minigraph parser changes for storage backend acl (#11221)
Signed-off-by: Neetha John nejo@microsoft.com

Why I did it
For storage backend, certain rules will be applied to the DATAACL table to allow only vlan tagged packets and drop untagged packets.

How I did it
Create DATAACL table if the device is a storage backend device
To avoid ACL resource issues, remove EVERFLOW related tables if the device is a storage backend device

How to verify it
Added the following unit tests
- verify that EVERFLOW acl tables is removed and DATAACL table is added for storage backend tor
- verify that no DATAACL tables are created and EVERFLOW tables exist for storage backend leaf
2022-07-06 10:27:05 -07:00
Longxiang Lyu
b9a7665662
[minigraph][dualtor] Support parsing soc_ip out of dpg (#11207)
Why I did it
To further support parse out soc_ipv4 and soc_ipv6 out of Dpg:

<DeviceDataPlaneInfo>
  <IPSecTunnels />
  <LoopbackIPInterfaces xmlns:a="http://schemas.datacontract.org/2004/07/Microsoft.Search.Autopilot.Evolution">
    <a:LoopbackIPInterface>
      <ElementType>LoopbackInterface</ElementType>
      <Name>HostIP</Name>
      <AttachTo>Loopback0</AttachTo>
      <a:Prefix xmlns:b="Microsoft.Search.Autopilot.NetMux">
        <b:IPPrefix>10.10.10.2/32</b:IPPrefix>
      </a:Prefix>
      <a:PrefixStr>10.10.10.2/32</a:PrefixStr>
    </a:LoopbackIPInterface>
    <a:LoopbackIPInterface>
      <ElementType>LoopbackInterface</ElementType>
      <Name>HostIP1</Name>
      <AttachTo>Loopback0</AttachTo>
      <a:Prefix xmlns:b="Microsoft.Search.Autopilot.NetMux">
        <b:IPPrefix>fe80::0002/128</b:IPPrefix>
      </a:Prefix>
      <a:PrefixStr>fe80::0002/128</a:PrefixStr>
    </a:LoopbackIPInterface>
    <a:LoopbackIPInterface>
      <ElementType>LoopbackInterface</ElementType>
      <Name>SoCHostIP0</Name>
      <AttachTo>server2SOC</AttachTo>
      <a:Prefix xmlns:b="Microsoft.Search.Autopilot.NetMux">
        <b:IPPrefix>10.10.10.3/32</b:IPPrefix>
      </a:Prefix>
      <a:PrefixStr>10.10.10.3/32</a:PrefixStr>
    </a:LoopbackIPInterface>
    <a:LoopbackIPInterface>
      <ElementType>LoopbackInterface</ElementType>
      <Name>SoCHostIP1</Name>
      <AttachTo>server2SOC</AttachTo>
      <a:Prefix xmlns:b="Microsoft.Search.Autopilot.NetMux">
        <b:IPPrefix>fe80::0003/128</b:IPPrefix>
      </a:Prefix>
      <a:PrefixStr>fe80::0003/128</a:PrefixStr>
    </a:LoopbackIPInterface>
  </LoopbackIPInterfaces>
</DeviceDataPlaneInfo>
Signed-off-by: Longxiang Lyu lolv@microsoft.com

How I did it
For servers loopback definitions in Dpg, if they contain LoopbackIPInterface with tags AttachTo, which has value of format like <server_name>SOC, the address will be regarded as a SoC IP, and sonic-cfggen now will treat the port connected to the server as active-active if the redundancy_type is either Libra or Mixed.

How to verify it
Pass the unittest.

Signed-off-by: Longxiang Lyu <lolv@microsoft.com>
2022-07-05 15:50:05 -07:00
judyjoseph
05f1c6f27f
[macsec] Parse masec_enabled and macsec_profile from minigraph (#10917)
* Updates needed to parse the macsec config from minigraph
* Add unit tests in tests/test_cfggen.py::TestCfgGen, and updates
2022-06-29 09:58:35 -07:00
Jing Kan
542cc0838c
[minigraph] Support parse IPv6 in device_desc.xml (#11095)
Signed-off-by: Jing Kan jika@microsoft.com
2022-06-28 20:14:53 +08:00
geogchen
6a9c058a92
Revert "Add support for generating interface configuration in /etc/network/interfaces for multiple management interfaces (#11204)" (#11241)
This reverts commit 90a849ea85.

#### Why I did it
The interfaces unit test did not cover some of the conditions in interfaces.j2 that was changed in #11204.  Therefore reverting the change and add the tests before making the change to interfaces.j2.

#### How I did it
Git revert.

#### How to verify it

#### Which release branch to backport (provide reason below if selected)


- [ ] 201811
- [ ] 201911
- [ ] 202006
- [ ] 202012
- [ ] 202106
- [ ] 202111
- [ ] 202205

#### Description for the changelog

#### Link to config_db schema for YANG module changes

#### A picture of a cute animal (not mandatory but encouraged)
2022-06-24 06:30:33 -07:00
geogchen
90a849ea85
Add support for generating interface configuration in /etc/network/interfaces for multiple management interfaces (#11204)
* [Interfaces] Modify template to support multiple management interfaces

* Modify minigraph to process interfaces in sorted order

Signed-off-by: Ubuntu <gechen@gechen-sonic-dev.d0r25nej54guppclip4gpy5b5a.jx.internal.cloudapp.net>

* Add UT minigraph

Signed-off-by: Ubuntu <gechen@gechen-sonic-dev.d0r25nej54guppclip4gpy5b5a.jx.internal.cloudapp.net>

* make case insensitve comparison

Signed-off-by: George Chen <gechen@microsoft.com>

* Use natural sort

Signed-off-by: George Chen <gechen@microsoft.com>

Co-authored-by: Ubuntu <gechen@gechen-sonic-dev.d0r25nej54guppclip4gpy5b5a.jx.internal.cloudapp.net>
2022-06-21 10:16:10 -07:00
bingwang-ms
b62526c46c
Define SYSTEM_DEFAULTS table to control tunnel_qos_remap (#10877)
* Define SYSTEM_DEFAULTS table to control tunnel_qos_remap

Signed-off-by: bingwang <wang.bing@microsoft.com>
2022-05-28 15:34:28 +08:00
arlakshm
915f2834b0
[voq][chassis]fix recirc port admin status (#10769)
Signed-off-by: Arvindsrinivasan Lakshmi Narasimhan arlakshm@microsoft.com

Why I did it
resolves #10761.
For VOQ chassis, the Recirc port, which was added for the Everflow, stays admin down after load minigraph.
This PR add the fix to make the recirc port as admin up

How I did it
The PR adds a change in minigraph.py,  if port has role as Rec make the the port as admin-status up.

How to verify it
UT

Signed-off-by: Arvindsrinivasan Lakshmi Narasimhan <arlakshm@microsoft.com>
2022-05-24 14:36:09 -07:00
Longxiang Lyu
8f7ef1e593
[dualtor][minigraph.py] Add soc_ipv4 and cable_type to MUX_CABLE (#10776)
Why I did it
To further add cable_type and soc_ipv4 field to table MUX_CABLE, this PR tries to parse the minigraph like the following:
```
      <Device i:type="SmartCable">
        <ElementType>SmartCable</ElementType>
        <SubType>active-active</SubType>
        <Address xmlns:d5p1="Microsoft.Search.Autopilot.NetMux">
          <d5p1:IPPrefix>192.168.0.3/21</d5p1:IPPrefix>
        </Address>
        <AddressV6 xmlns:d5p1="Microsoft.Search.Autopilot.NetMux">
          <d5p1:IPPrefix>::/0</d5p1:IPPrefix>
        </AddressV6>
        <ManagementAddress xmlns:d5p1="Microsoft.Search.Autopilot.NetMux">
          <d5p1:IPPrefix>0.0.0.0/0</d5p1:IPPrefix>
        </ManagementAddress>
        <ManagementAddressV6 xmlns:d5p1="Microsoft.Search.Autopilot.NetMux">
          <d5p1:IPPrefix>::/0</d5p1:IPPrefix>
        </ManagementAddressV6>
        <SerialNumber i:nil="true" />
        <Hostname>svcstr-7050-acs-1-Servers0-SC</Hostname>
      </Device>
      <Device i:type="Server">
        <ElementType>Server</ElementType>
        <Address xmlns:d5p1="Microsoft.Search.Autopilot.NetMux">
          <d5p1:IPPrefix>192.168.0.2/21</d5p1:IPPrefix>
        </Address> 
        <AddressV6 xmlns:d5p1="Microsoft.Search.Autopilot.NetMux">
          <d5p1:IPPrefix>fc02:1000::2/64</d5p1:IPPrefix>
        </AddressV6>
        <ManagementAddress xmlns:d5p1="Microsoft.Search.Autopilot.NetMux">
          <d5p1:IPPrefix>0.0.0.0/0</d5p1:IPPrefix>
        </ManagementAddress>
        <Hostname>Servers0</Hostname>
      </Device>
```
Signed-off-by: Longxiang Lyu lolv@microsoft.com

How I did it
get_mux_cable_entries will try to get the mux cable device from the devices list and get the cable type and soc ip address from the device definition.

How to verify it
Pass the unit-test
2022-05-24 15:10:48 +08:00
Qi Luo
936d93cbcd
Fix tagged VlanInterface if attached to multiple vlan as untagged member (#8927)
#### Why I did it
Fix several bugs:
1. If one vlan member belongs to multiple vlans, and if any of the vlans is "Tagged" type, we respect the tagged type
2. If one vlan member belongs to multiple vlans, and all of the vlans have no "Tagged" type, we override it to be a tagged member
3. make sure `vlantype_name` is assigned correctly in each iteration

#### How to verify it
1. Test the command line to parse a minigraph and make sure the output does not change.
```
./sonic-cfggen -m minigraph.mlnx20.xml
```
The minigraph is for HwSKU Mellanox-SN2700-D40C8S8.

2. Test on a DUT with HwSKU Mellanox-SN2700-D40C8S8
```
sudo config load_minigraph
show vlan brief
```
Checked the "Port Tagging" column in the output.
2022-04-19 15:47:07 -07:00
ganglv
29f6b01be6
[sonic-cfggen]: Fix generated deployment_id (#10154)
Why I did it
Config db schema generated by minigraph can’t pass yang validation, deployment_id can’t be none for yang validation.

How I did it
Update minigraph.py, skip deployment_id with None value

How to verify it
Run UT for sonic-config-enginue.
Run command 'sonic-cfggen -m tests/multi_npu_data/sample-minigraph-noportchannel.xml -p tests/multi_npu_data/sample_port_config-3.ini -n asic3 --print-data'.

Signed-off-by: Gang Lv ganglv@microsoft.com
2022-03-08 15:48:04 +08:00
Jing Kan
914a8a1756
[sonic-config-engine]: Update minigraph parser to support enable DHCP server for BmcMgmtToRRouter (#9938)
Signed-off-by: Jing Kan jika@microsoft.com
2022-02-10 13:30:54 +08:00
ganglv
d3c39d5324
[sonic-cfggen]: Feature should use 'state' to replace 'status' (#9796)
Why I did it
ConfigDB schema generated by minigraph parser can't pass yang validation.

How I did it
Modify minigraph.py, and use 'state' to replace 'status'.

How to verify it
Run UT for sonic-config-engine.
Use minigraph parser to generate ConfigDB schema, and run yang validation.

Signed-off-by: Gang Lv ganglv@microsoft.com
2022-01-20 08:51:56 +08:00
abdosi
649e6c7307
[minigraph] Enhanced parser to parse interface name for static route nexthop (#9707)
What I did:-

Enhanced minigraph parser to parse interface name associated with static route nexthop

Why I did:-

One of the use case to support interface name is Chassis Packet. For Chassis Packet we have Static Routes configured to route traffic across line-card. If the FRR programs static route without the interface name then in case if the ip interface that is associated with the nexthop goes down FRR resolves static route nexthop over the default route as we have FRR config ip nht-resolve-via-default which causes undesired behavior. Having interface name with Static Route prevents recursive lookup on default route.

How I verify:

Updated unit-test cases
Manual verification
2022-01-12 18:48:23 -08:00
Qi Luo
d7ffcf1773
[minigraph] do not use NULL:NULL explicitly in json (#9703)
#### Why I did it
It should be handled by `ConfigDBConnector.typed_to_raw()`.

This is a bug for `sonic-cfggen -m --print-data` only
```
    "PORTCHANNEL_MEMBER": {
        "PortChannel0001|Ethernet112": {
            "NULL": "NULL"
        },
        "PortChannel0002|Ethernet116": {
            "NULL": "NULL"
        },
        "PortChannel0003|Ethernet120": {
            "NULL": "NULL"
        },
        "PortChannel0004|Ethernet124": {
            "NULL": "NULL"
        }
    },
```
But not appears in `sonic-cfgen -d --print-data`.
```
    "PORTCHANNEL_MEMBER": {
        "PortChannel0001|Ethernet112": {},
        "PortChannel0002|Ethernet116": {},
        "PortChannel0003|Ethernet120": {},
        "PortChannel0004|Ethernet124": {}
    },
```
Tested in a T0 KVM.
2022-01-07 22:20:31 -08:00
thomas.cappleman@metaswitch.com
7ebe44a2a0
[chassis] Fix uninitialized variable in minigraph parsing (#8917)
Why I did it
Local variable may not be created in minigraph parsing, causing crash

How I did it
Moved variable creation earlier
2021-12-07 11:33:17 -08:00
abdosi
950ec3e68b
Added option to enable/disable Static Route Advertisement (#9298)
What I did:

Added option 'advertise':'true'/'false' to STATIC_TALE to control whether given route need to be advertise into BGP.

How I did:

Add a route in FRR with tag (1 for advertise and 2 for not advertise)
Create Route Map to match on tag as 1 and permit
Attach route-map to redistribute static.
Minigraph option to parse advertise option of Static Route.
2021-11-24 09:43:37 -08:00
Qi Luo
06bf76b5bc
[minigraph] No longer generate the “members” field on the VLAN table in ConfigDB (#9237)
#### Why I did it
This field is deprecated.
Fixes https://github.com/Azure/sonic-buildimage/issues/8306
Fixes https://github.com/Azure/sonic-buildimage/issues/9121
2021-11-18 18:03:11 -08:00
anamehra
fed19e3fb5
Added get_system_mac support for cisco-8000 device (#9104)
Added get_system_mac support for cisco-8000 device

Why I did it
This is required to assign unique MACs to namespaces on Backend and Frontend asics
for cisco-8000 platforms

How I did it
Add vendor specific hook in get_system_mac. The MAC address are read from /profile.ini
file

How to verify it
config load_minigraph on a multi-asic system
config save
check mac addresses in DEVICE_METADATA section in each config_db json file
2021-11-04 08:27:55 -07:00
abdosi
919b3e5cdf
[chassis-packet] Fixed BGP Internal Peer template (#9106)
What I did:

Fix the typo in Internal Peer Group template for Packet-based Chassis.
Address Review comments of PR: [chassis-packet] minigraph parsing and BGP template changes #8966
- Static Route Parsing for Host
- Formatting of chassis port_config.ini
2021-10-29 11:02:38 -07:00
Neetha John
d35b50b116
[minigraph] Add tagged vlan member support for storage backend (#9045)
Signed-off-by: Neetha John <nejo@microsoft.com>

Why I did it
Storage T0's have all vlan members as tagged

How I did it
Since currently minigraph does not have a unique way to identify if a vlan member is tagged/untagged and to ensure other scenarios are not broken, the logic used is to just update the vlan member type as 'tagged' when we determine that it is a storage backend device. This change will apply only to storage backend T0's since storage backend T1's will not have vlan member information

How to verify it
Updated the storage backend T0 testcases to check for tagged vlan members
Added testcase to check if a T1 and backend T1 device generates an empty vlan member table
Existing vlan member testcases are good enough for checking if any regression has been caused for regular T0's
Build sonic_config_engine-1.0-py3-none-any.whl successfully
2021-10-27 09:27:18 -07:00