**- Why I did it**
- Skip thermalctld in DellEMC S6000, S6100, Z9100 and Z9264 platforms.
- Change the return type of thermal Platform APIs in DellEMC S6000, S6100 and Z9100 platforms to 'float'.
**- How I did it**
- Add 'skip_thermalctld:true' in pmon_daemon_control.json for DellEMC S6000, S6100, Z9100 and Z9264 platforms.
- Made changes in thermal.py, for 'get_temperature', 'get_high_threshold' and 'get_low_threshold' to return 'float' value.
**- How to verify it**
- Check thermalctld is not running in 'pmon'.
- Wrote a python script to load Chassis class and then call the APIs accordingly and verify the return type.
Make sure db_migrator is run after all config are loaded during (#926)
Vnet alias mapping (#924)
Changes to make lldp show command for multi-npu platforms. (#914)
[Mellanox] Fix thermal control issue: use natural sort for fan
status and thermal status (#836)
[Mellanox] add document for thermal control related cli (#832)
[aclorch] Add support for creating ingress and egress MIRROR tables
concurrently (#1286)
[proxy_arp] Implement proxy ARP feature (#1302)
Fix LAG member test case (#1304)
[orchagent] Set default MTU for the underlay loopback interface (#1299)
This change allows the recursive `git clean` and `git reset` commands to continue even if they encounter an error in one of the submodules. Previously, if an error was encountered, the operation would terminate with a message similar to the following:
Stopping at 'src/sonic-mgmt-framework'; script returned non-zero status.
I found that with IPv4Network types, calling list(ip_ntwrk.hosts()) is reliable. However, when doing the same with an IPv6Network, I found that the conversion to a list can hang indefinitely. This appears to me to be a bug in the ipaddress.IPv6Network implementation. However, I could not find any other reports on the web.
This patch changes the behavior to call next() on the ip_ntwrk.hosts() generator instead, which returns the IP address of the first host.
Since the introduction of VRF, interface-related tables in ConfigDB will have multiple entries, one of which only contains the interface name and no IP prefix. Thus, when iterating over the keys in the tables, we need to ignore the entries which do not contain IP prefixes.
Modified caclmgrd behavior to enhance control plane security as follows:
Upon starting or receiving notification of ACL table/rule changes in Config DB:
1. Add iptables/ip6tables commands to allow all incoming packets from established TCP sessions or new TCP sessions which are related to established TCP sessions
2. Add iptables/ip6tables commands to allow bidirectional ICMPv4 ping and traceroute
3. Add iptables/ip6tables commands to allow bidirectional ICMPv6 ping and traceroute
4. Add iptables/ip6tables commands to allow all incoming Neighbor Discovery Protocol (NDP) NS/NA/RS/RA messages
5. Add iptables/ip6tables commands to allow all incoming IPv4 DHCP packets
6. Add iptables/ip6tables commands to allow all incoming IPv6 DHCP packets
7. Add iptables/ip6tables commands to allow all incoming BGP traffic
8. Add iptables/ip6tables commands for all ACL rules for recognized services (currently SSH, SNMP, NTP)
9. For all services which we did not find configured ACL rules, add iptables/ip6tables commands to allow all incoming packets for those services (allows the device to accept SSH connections before the device is configured)
10. Add iptables rules to drop all packets destined for loopback interface IP addresses
11. Add iptables rules to drop all packets destined for management interface IP addresses
12. Add iptables rules to drop all packets destined for point-to-point interface IP addresses
13. Add iptables rules to drop all packets destined for our VLAN interface gateway IP addresses
14. Add iptables/ip6tables commands to allow all incoming packets with TTL of 0 or 1 (This allows the device to respond to tools like tcptraceroute)
15. If we found control plane ACLs in the configuration and applied them, we lastly add iptables/ip6tables commands to drop all other incoming packets
For detecting transceiver change events through xcvrd in DellEMC S6000, S6100 and Z9100 platforms.
- In S6000, rename 'get_transceiver_change_event' in chassis.py to 'get_change_event' and return appropriate values.
- In S6100, implement 'get_change_event' through polling method (poll interval = 1 second) in chassis.py (Transceiver insertion/removal does not generate interrupts due to a CPLD bug)
- In Z9100, implement 'get_change_event' through interrupt method using select.epoll().
* [ntp] enable/disable NTP long jump according to reboot type
- Enable NTP long jump after cold reboot.
- Disable NTP long jump after warrm/fast reboot.
Signed-off-by: Ying Xie <ying.xie@microsoft.com>
* fix typo
* further refactoring
* use sonic-db-cli instead
* The following changes for multi-npu platforms are done
- Set the type in device_metadata for asic configuration to be same as host
- Set the admin-status of internal bgp sessions as up
Signed-off-by: Arvindsrinivasan Lakshmi Narasimhan <arlakshm@microsoft.com>
* Changes to support config-setup service for multi-npu
platforms. For Multi-npu we are not supporting as of
now config initializtion and ZTP. It will support creating
config db from minigraph or using config db from previous
file system
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
* Address Review Comments.
* Address Review comments
* Address Review Comments of using pyhton based config load_minigraph/
config save/config reload from shell scripts so that we don't duplicate
code. Also while running from shell we will skip stop/start services
done by those commands.
* Updated to use python command so no code duplication.
* Adding new BGP peer groups PEER_V4_INT and PEER_V6_INT. The internal BGP sessions
will be added to this peer group while the external BGP sessions will be added
to the exising PEER_V4 and PEER_V6 peer group.
* Check for "ASIC" keyword in the hostname to identify the internal neighbors.
[201911][show] Fix abbreviations for 'show ip bgp ...' commands (#909)
Changes to support acl-loader and mirror-session config commands for
multi-npu platforms. (#908)
Changes to commands config reload/load-minigraph (#919)
Stop/Start restapi server upon config reload (#911)
[config] Add 'interface transceiver' subgroup with 'lpmode' and
'reset' subcommands (#904)
and then we load image and reboot even if there was existing
config_db.json we will look for DHCP Service. we should disbale
update_graph in such cases. This behaviour is silimar to what we have in
201811 image.
* Moved utility functions for multi-npu platforms from
sonic-utilities config/main.py to here so that they can be used
any module
* Fix the issue with test run during compilation with acl-uploader
PR#908 of sonic-utilities.
* Fix get_num_npu as it was retuning string and not int
* Address Review Comments
* Address Review Comments
* Changes for LLDP for Multi NPU Platoforms:-
a) Enable LLDP for Host namespace for Management Port
b) Make sure Management IP is avaliable in per asic namespace
needed for LLDP Chassis configuration
c) Make sure chassis mac-address is correct in per asic namespace
d) Do not run lldp on eth0 of per asic namespace and avoid chassis
configuration for same
e) Use Linux hostname instead from Device Metadata for lldp chassis
configuration since in multi-npu platforms device metadata hostname
will be differnt
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
* Address Review Comment with following changes:
a) Use Device Metadata hostname even in per namespace conatiner.
updated minigraph parsing for same to have hostname as system
hostname and add new key for asic name
b) Minigraph changes to have MGMT_INTERFACE Key in per asic/namespace
config also as needed for LLDP for setting chassis management IP.
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
* Address Review Comments
* [sonic-buildimage] updated minigraph for ACL Table data and ACL Interface
binding update for multu-npu platform based on subrole as "Frontend" or
"Backend". For backend npu no ACL table is associated. For frontend npu
only front-panel interface are associated.
Updated with test case and fix typo in sample-mingraph for npu
Address Review comments
Signed-off-by: Abhishek Dosi <abdosi@microsoft.com>
* Fixed the logic as per preview comment. Interface Filter logic
only applies to Everflow/Mirror tables.
* Address Review Comments.